Consultation with SebaKMT User Manual Wireless Reading Device PocketServer-3 Mess- und Ortungstechnik Measuring and Locating Technologies Elektrizitätsnetze Power Networks Kommunikationsnetze Communication Networks Rohrleitungsnetze Water Networks Abwassernetze Sewer Systems Leitungsortung Line Locating Issue: Article number: 1 01 (10/2017) - EN **
Consultation with SebaKMT 2
Consultation with SebaKMT Consultation with SebaKMT The present system manual has been designed as an operating guide and for reference. It is meant to answer your questions and solve your problems in as fast and easy a way as possible. Please start with referring to this manual should any trouble occur. In doing so, make use of the table of contents and read the relevant paragraph with great attention. Furthermore, check all terminals and connections of the instruments involved.
Terms of Warranty Terms of Warranty SebaKMT accept responsibility for a claim under warranty brought forward by a customer for a product sold by SebaKMT under the terms stated below. SebaKMT warrant that at the time of delivery SebaKMT products are free from manufacturing or material defects which might considerably reduce their value or usability. This warranty does not apply to faults in the software supplied.
Terms of Warranty Contents Consultation with SebaKMT ...........................................................................................3 Terms of Warranty ...........................................................................................................4 1 Safety instructions ...........................................................................................9 1.1 General safety instructions and warnings ..........................................................9 1.
Terms of Warranty 4.9 GPS position ....................................................................................................35 4.10 Firmware update ..............................................................................................36 5 LOG P-3 / P-3 mini ..........................................................................................38 5.1 Managing loggers in PS-3 ................................................................................38 5.
Terms of Warranty 7.12 Firmware update ..............................................................................................72 8 PS-3 – Status & settings ................................................................................74 8.1 Device info ........................................................................................................74 8.2 8.2.1 8.2.2 8.2.3 8.2.4 Settings...................................................................................................
Terms of Warranty 8
Safety instructions 1 Safety instructions 1.1 General safety instructions and warnings Do not drop the device / the system’s components or subject it / them to strong impacts or mechanical shocks. The limits described under Technical Data may not be exceeded. The device / system must be in a technically perfect condition for measurement. 1.2 General notes Safety precautions This manual contains basic instructions for the commissioning and operation of the device / system.
Safety instructions Special transportation The lithium batteries of the device are dangerous goods. The transport of the batteries requirements itselves and of devices which contain such batteries is subject to regulations based on the UN Model Regulations “Transport of Dangerous Goods” (ST/SG/AC.10-1). Please inform yourself about the transportation requirements and follow them when shipping the device. Electromagnetic This device is designed for industrial use.
PS-3 - Basics 2 PS-3 - Basics 2.1 Technical data The PocketServer is distinguished by the following technical parameters: 2.2 Parameter Value Communication Short range radio 868 MHz (in Europe) 913.02 MHz (in the US) 913 / 916 MHz (depending on the country) WIFI Access-Point 2.4 GHz Storage Internal 8 GB Micro SD card (approx. 6.5 GB free for measured and device data) Battery Internal rechargeable battery pack (Li-Ion) 3.6 V, 4700 mAh Charger 5V, 2A Operating time approx.
PS-3 - Basics 2.3 Connections USB port Connects to a USB data storage device. Connection for the radio module LOG RI+ Connection for charger 2.4 Type plate Identification number (ID) Access to PocketServer WLAN SSID: Name of WLAN PW: Password for WLAN Type designation The last three digits correspond to the radio frequency of the device (here: 868 MHz). 2.5 Switching on/off Switching on To switch on the PocketServer, briefly press the I/O button on the device. The blue and one green LED light up.
PS-3 - Basics Switching off There are two ways to turn off the PocketServer. Option 1: in the user interface ► Tap these keys one after the other: Option 2: with the I/O button on the PocketServer ► Press the I/O button on the unit for about two seconds. Release the button as soon as the green LEDs go out. The device takes some time to shut down the internal processor. During this time, a single green LED is on.
PS-3 - Basics Header/footer In the segment at the top of the screen, the currently open device type is shown. In the segment on the bottom of the screen, current information on the status of the PocketServer is shown. Upper line (from left to right): Utilization of internal data storage; Name of the displayed menu or ID of the contacted device; Battery level; Bottom line: Date and time of the PocketServer; Once a data transfer takes place, a bar here shows the progress of the procedure.
PS-3 – Commissioning 3 PS-3 – Commissioning Here you can find information about what needs to be done after switching on the PocketServer in order to make the device ready for operation. 3.
PS-3 – Commissioning 3.2 Starts after the first connection After the first connection, access to the PocketServer WLAN is saved in your mobile device. The devices detect each other and automatically connect from then on. ► Switch the PocketServer on. ► Wait until the WiFi symbol is shown in the status bar of the mobile device. ► Tap on the LOG PS-3 button in the start screen.
LOG N-3 4 LOG N-3 Here you can find information about all functions that are available for working with LOG N-3 sound loggers. 4.1 Managing loggers in PS-3 4.1.1 Logger group To create, edit or delete logger groups in the PocketServer, proceed as follows: ► In the start screen, tap LOG N-3. ► Tap Patrol mode when you want to create or edit a Patrol group. Tap Lift&Shift when you want to create or edit a Lift&Shift group. The display area is divided in two.
LOG N-3 Adding loggers ► In the Group list, select the corresponding group. to the group ► Tap Edit group. The display area is divided in two. In the Function section you will find the functions for editing the group. In the Devices section, all loggers in this group are listed. Option 1: Entry of the ID ► Tap Add. A dialogue window opens. ► Enter the identification number (ID) of the logger. ► Tap Add. The dialogue window closes. The newly created logger now appears in the device list.
LOG N-3 Creating loggers Option 1: Entry of the ID ► Tap Create. A dialogue window opens. ► Enter the identification number (ID) of the new logger. You can also enter a comment on the device. ► Tap Create. The dialogue window closes. The newly created logger now appears in the Devices list. Option 2: Automatic detection ► Tap Auto-Detection. ► Switch the logger on. The ID of the logger is recognised by the PocketServer. The logger now appears in the Devices list. ► Tap Stop auto-detection.
LOG N-3 4.2 Reading the measured data 4.2.1 Patrol Requirement: It is recommended that you connect the optional external wireless module LOG RI+ to the PocketServer because the limited range of the internal wireless module only allows a limited patrol. Procedure: ► In the start screen, tap LOG N-3. ► Tap Patrol mode. ► Select the desired logger group in the Groups list. ► Tap Start Patrol mode. The patrol begins. The radio LED on the LOG RI+ or on the PocketServer lights up.
LOG N-3 4.2.3 Reading out single loggers To read out measured data from an individual logger, proceed as follows: ► In the start screen, tap LOG N-3. ► Tap Single device. ► Select the desired logger from the Devices list. ► Tap Measurement data. The connection to the logger is established. The data is received by the PocketServer and displayed on the screen. After closing the measurement data display, you will find this data record in the Data list. It can be accessed and displayed there at any time. 4.
LOG N-3 The set alarm threshold of this logger Displaying If you tap the ID of a logger in the alarm state, the complete measurements of this measurements logger are accessed. The measured data display opens. X-axis … course of measurement over time Y-axis … level in dB Each bar represents a single measurement. The height of the bar represents the measured level. The colour of the bar represents the measured frequency. 0 Hz 3300 Hz The horizontal green line represents the set alarm threshold.
LOG N-3 Individual values For each individual measurement in the digram, you can find the measured level (dB), the frequency (Hz) and the exact time of the measurement. ► Touch the desired bar in the diagram. A vertical red line appears (cursor). The values can be read on this line. The green highlighted box indicates the alarm threshold (here: 20 dB). Legend You can view additional information about the diagram view. ► Tap the button . ► In the context menu, tap Legend.
LOG N-3 4.3.2 Data of a Lift&Shift group To access the measured data of a Lift&Shift group, proceed as follows: ► In the start screen, tap LOG N-3. ► Tap Lift&Shift. ► Select the desired logger group in the Groups list. ► Select the desired measured data from the Data list. The measured data display opens. The measured values of the first logger of the group are displayed in a diagram. X-axis … course of measurement over time Y-axis … level in dB Each bar represents a single measurement.
LOG N-3 Option 2: ► Slide the two control elements to the left/right at the top of the diagram. Reset: ► Tap Show all to reset the view. Individual values For each individual measurement in the digram, you can find the measured level (dB), the frequency (Hz) and the exact time of the measurement. ► Touch the desired bar in the diagram. A vertical red line appears (cursor). The values can be read on this line. The green highlighted box indicates the alarm threshold (here: 20 dB).
LOG N-3 4.3.3 Data of an individual logger All measured data that has been read and stored from a logger is available in the PocketServer under the ID of this logger. It does not matter whether the data was requested by patrolling or by Lift&Shift. To access a measurement record of a logger, proceed as follows: ► In the start screen, tap LOG N-3. ► Tap Single device. ► Select the desired logger from the Devices list. ► Select the desired measured data from the Data list. The measured data display opens.
LOG N-3 Individual values For each individual measurement in the digram, you can find the measured level (dB), the frequency (Hz) and the exact time of the measurement. ► Touch the desired bar in the diagram. A vertical red line appears (cursor). The values can be read on this line. The green highlighted box indicates the alarm threshold (here: 20 dB). Legend You can view additional information about the diagram view. ► Tap the button . ► In the context menu, tap Legend.
LOG N-3 4.4 Reading out audio files If you want to listen to the sound of a logger, you must read out the audio file of this noise from this logger. Requirement: The corresponding logger must not have been switched off since the measurement. Procedure: ► In the start screen, tap LOG N-3. ► Tap Single device. ► Select the desired logger from the Devices list. ► Tap Audio. The connection to the logger is established. The audio file of the last measurement is received by the PocketServer.
LOG N-3 Measurement settings Operation mode Displays the mode of the logger (Patrol/Lift&Shift/Network/configuration mode) Measurement ON Start time of the measurement Measurement OFF End of the measurement Values per measurement Number of measurements per measurement day Leak threshold Level that is set as alarm threshold Measurement days Days of the week on which measurements take place Radio ON Time starting from which the logger is available by radio (internal wireless module is activated
LOG N-3 4.6 Programming INFO The function ‘Programming devices’ does not belong to the PocketServer basic equipment. It is only available after acquisition and input of a license key in the device. 4.6.1 Logger groups To program a logger group, proceed as follows: ► In the start screen, tap LOG N-3. ► Tap Patrol mode when you want to program a Patrol group. Tap Lift&Shift when you want to program a Lift&Shift group. ► Select the desired logger group in the Groups list. ► Tap Program group.
LOG N-3 INFO For detailed explanations of the individual settings, refer to the operating instructions of the LOG N-3 system. ► Tap Send to program the logger group now, or tap Store if you want to program the loggers at a later time. For Send, the configuration of the PocketServer is transmitted to all loggers of the group and applied there. At the end of the operation, it is displayed which loggers could be successfully programmed and which could not. If necessary, repeat the procedure.
LOG N-3 Radio days Specify the days of the week the logger is available via radio. Transmission interval If the Patrol mode is set, select the transmission interval of the logger here. INFO For detailed explanations of the individual settings, refer to the operating instructions of the LOG N-3 system. ► Tap on the Send button at the bottom of the input mask. The configuration is sent from the PocketServer to the logger and applied there. A success message appears at the end of the operation. 4.
LOG N-3 ► In the PocketServer start screen, tap LOG N-3. ► Tap Single device. ► Select the desired logger from the Devices list. ► Tap the button . ► In the context menu, tap Export. All data saved in the PocketServer for this logger (measured data, configuration data, event lists, etc.) is copied to the USB stick. A success message appears at the end of the operation.
LOG N-3 4.8 Real-time measurements You can perform a real-time measurement with a single logger. The measured values are displayed ‘live’ on the screen. NOTE The real-time measurement requires a great deal of energy and considerably reduces the battery life of the logger. Only use the real-time measurement for as long as necessary. Requirements: The relevant logger must be installed at the desired measurement point. The logger must be switched on and ready for wireless operation.
LOG N-3 ► Tap Realtime view. ► Select the desired option from the drop-down list. Example: If you select the option Show all, each new recording will be added to the diagram. All values of the running real-time measurement can be seen in the diagram. If you select the option 10 values, only the last 10 recordings are displayed in the diagram. When each new recording is added, the oldest recording disappears from the view. ► Confirm with OK. ► With the button, you can return to the real-time measurement.
LOG N-3 4.10 Firmware update SebaKMT provides regularly updated versions of the firmware at www.sebakmt.com for all devices. Check and update regularly the firmware of your devices. Identifying the In order to determine which firmware version is currently installed on a N-3 logger, read firmware version out its configuration. ► In the PocketServer start screen, tap Log N-3 ► Tap Single device. ► Select the logger from the Devices list. ► Tap Settings. The connection to the logger is established.
LOG N-3 If an error occurs (error message), the process must be restarted. After successful data transfer, the new firmware is installed on the device. The device is then restarted. The firmware update is now complete. If you read out the configuration of the device, under Device info, the new firmware version is displayed. Safely removing the To safely remove the USB stick from the PocketServer, follow these steps: USB device ► Tap the button . ► Tap USB. ► Tap Remove USB device.
LOG P-3 / P-3 mini 5 LOG P-3 / P-3 mini Here you can find information about all functions that are available for working with LOG P-3 and LOG P-3 mini pressure loggers. 5.1 Managing loggers in PS-3 To create, edit or delete loggers in the PocketServer, proceed as follows: ► In the start screen, tap LOG P-3/LOG P-3-mini. The menu of the same name opens. Display area The display area is divided in two. Under the Function section you will find the functions for creating loggers.
LOG P-3 / P-3 mini Deleting loggers ► Tap the button . ► In the context menu, tap Delete. ► Select the desired logger from the Devices list. ► Answer the confirmation prompt with OK. The logger disappears from the device list. All data of the logger are deleted from the PocketServer. ► Tap the button 5.2 . Reading the measured data To read out the measured data, proceed as follows: ► In the start screen, tap LOG P-3/LOG P-3-mini. ► Select the desired logger from the Devices list.
LOG P-3 / P-3 mini X-axis … course of measurement over time Y-axis … measurements Zoom You can narrow the chart view to any time range. Option 1: ► Touch a point on the diagram and slide your finger to the side to highlight the desired area. Option 2: ► Slide the two control elements to the left/right at the top of the diagram. Reset: ► Tap Show all to reset the view. Individual values For each individual measurement in the diagram, you can find the measured value and the exact time of the measurement.
LOG P-3 / P-3 mini Metadata You can display additional information about this data record. ► Tap the button . ► In the context menu, tap File info. Above the diagram, a new area opens in which the data are listed. ► To hide, tap again on 5.4 button and then on Hide info. Reading out a configuration You can read out the current configuration of a logger. The measurement and wireless settings and the general status information of this logger are queried. ► In the start screen, tap LOG P-3/LOG P-3-mini.
LOG P-3 / P-3 mini Measurement settings Interval Measurement interval Pressure shocks Displays whether pressure shocks are recorded (checkbox is activated) or not (checkbox is deactivated). Unit Unit of measure End of measurement Displays whether an end time has been set for the measurement (checkbox is activated) or not (checkbox is deactivated). 5.5 Reading out pressure shocks When reading the measured data, the pressure shock recordings are not transferred.
LOG P-3 / P-3 mini ► In the PocketServer start screen, tap LOG P-3/LOG P-3-mini. ► Select the desired logger from the Devices list. ► Tap Realtime. The connection to the logger is established. The logger starts to measure. The recorded values are received in real time by the PocketServer and displayed in a diagram as a curve. Stopping/resuming a ► Tap the Stop button in the top left to stop the current measurement. measurement The logger stops recording and transmitting data to the PocketServer.
LOG P-3 / P-3 mini 5.7 GPS position You can determine and store the GPS data for the location of a logger. Requirements: Your mobile device (smartphone or tablet etc.) must be GPS-capable. The GPS function of your mobile device must be activated (location services activated). Procedure: ► Go to the installation location of the logger with your mobile device. ► In the PocketServer start screen, tap LOG P-3/LOG P-3-mini. ► Select the desired logger from the Devices list. ► Tap the button .
LOG P-3 / P-3 mini pressure change to be a ‘pressure shock’. Activate the checkbox 10Hz sampling, if the recording should take place with an extra high sampling rate. Caution: The high sampling rate subjects the logger battery to an extremely high load! When the checkbox is deactivated, the sampling rate is only 1 Hz. Unit Select the measuring unit for the measurements. Storage Activate/deactivate the ring storage function for the data storage of the logger.
LOG P-3 / P-3 mini ► Tap the button . ► In the context menu, tap Export. The data is transmitted. A success message appears at the end of the operation. Safely removing the To safely remove the USB stick from the PocketServer, follow these steps: USB device ► Tap the button . ► Tap USB. ► Tap Remove USB device. You can now remove the USB stick. 5.10 Firmware update SebaKMT provides regularly updated versions of the firmware at www.sebakmt.com for all devices.
LOG P-3 / P-3 mini ► In the second list, select the device to be updated. ► Tap Install. The update begins! NOTE Do not interrupt the process. Do not make any entries until the update is complete. The connection between PocketServer and device is established. The firmware data is transmitted. The wireless LED of the PocketServer lights up blue. The status LED on the logger lights up blue. Progress of the procedure is displayed on the screen.
LOG D-3 / SebaFlow / TDM 300 6 LOG D-3 / SebaFlow / TDM 300 Here you can find information about all functions that are available for working with LOG D-3 data loggers and SebaFlow and TDM 300 devices. 6.1 Managing devices in PS-3 Each logger and device to be contacted must be logged into PocketServer. ► In the start screen, tap LOG D-3 / SF / TDM 300. The menu of the same name opens. Display area The display area is divided into two areas.
LOG D-3 / SebaFlow / TDM 300 Deleting a device ► Tap the button . ► In the context menu, tap Delete. ► Select the desired device from the Devices list. ► Answer the confirmation prompt with OK. The device disappears from the device list. All data of the device are deleted from the PocketServer. ► Tap the button 6.2 . Reading the measured data To read out the measured data from the device, proceed as follows: ► In the start screen, tap LOG D-3 / SF / TDM 300.
LOG D-3 / SebaFlow / TDM 300 X-axis … course of measurement over time Y-axis … measurements Up to four curves can be seen: Blue Red Green Orange … Measuring channel 1 … Measuring channel 2 … Measuring channel 3 … Measuring channel 4 Hiding a curve You can hide any of the curves in the diagram view. ► Click on the corresponding coloured rectangle under the diagram. To show it again, tap on the same rectangle. Zoom You can narrow the chart view to any time range.
LOG D-3 / SebaFlow / TDM 300 A vertical red line appears (cursor). The time of the individual recording is displayed at the base of the line. At the intersections with each curve, the measured value can be read. Metadata You can display additional information about this data record. ► Tap the button . ► In the context menu, tap File info. Above the diagram, a new area opens in which the data are listed. ► To hide, tap again on 6.4 button and then on Hide info.
LOG D-3 / SebaFlow / TDM 300 Comment Comment text for this device Measurement settings Interval Currently set measurement interval The Channel 1 to Channel 4 drop-down menus show which measurement channels are activated and which sensor settings have been made. The Alarm input 1 and Alarm input 2 drop-down menus show whether alarmtriggering devices are connected. GSM settings GSM active indicates whether or not the GSM function of the device is activated.
LOG D-3 / SebaFlow / TDM 300 6.6 Reading out night values This function reads the lowest and the highest reading of the previous night* from the logger/device. ► In the start screen, tap LOG D-3 / SF / TDM 300. ► Select the desired device from the Devices list. ► Tap Night data. The connection to the device is established. The data is received by the PocketServer and displayed on the screen. The largest measurement value per measuring channel is specified by Max value.
LOG D-3 / SebaFlow / TDM 300 ► Select the desired device data from the Devices list. ► Tap Realtime. The connection to the device is established. The device starts to measure. The recorded values are received in real time by the PocketServer and displayed in a diagram. Up to four curves can be seen. Each curve represents a measurement channel of the device. Stopping/resuming a in the top left to stop the current measurement.
LOG D-3 / SebaFlow / TDM 300 6.9 GPS position You can determine and store the GPS data for the location of a logger/device. Requirements: Your mobile device (smartphone or tablet etc.) must be GPS-capable. The GPS function of your mobile device must be activated (location services activated). Procedure: ► Go to the installation location of the device with your mobile device. ► In the PocketServer start screen, tap LOG D-3 / SF / TDM 300. ► Select the desired device from the Devices list.
LOG D-3 / SebaFlow / TDM 300 Interval Select the measurement interval Channel 1 to Channel 4 drop-down menus You can find the measurement-channel specific settings here: Channel active Activate/deactivate the measurement channel for the measurement. A deactivated channel does not participate in the measurement. All sensor settings are then hidden. Sensor Select the connected sensor type from the list.
LOG D-3 / SebaFlow / TDM 300 GSM settings GSM active active checkbox Radio transmission possible Radio transmission not possible When this checkbox is deactivated, the device cannot send or receive cellular signals. Enter the 4-digit PIN for the SIM card used in the device. Internet settings (APN) Enter the data required for internet access (server address, DNS1, DNS2, user name, password).
LOG D-3 / SebaFlow / TDM 300 E-mail active checkbox Should e-mail notifications be issued? E-mails possible E-mails not possible When this checkbox is deactivated, it is not possible for the device to send alarm or status messages via e-mail. Alarm/Status radio buttons Select the type of notifications that will be issued: Only alarms; alarms and 1x status per day; alarms and 1x status per week Weekday/Time Enter the time and weekday for receiving status messages.
LOG D-3 / SebaFlow / TDM 300 6.11 Export data You can connect a USB data store to the PocketServer and copy data from the PocketServer to the USB stick. From the USB stick, the data can then be imported to the SebaDataView-3 software. ► Connect the USB stick to the USB socket of the PocketServer. ► In the PocketServer start screen, tap LOG D-3 / SF / TDM 300.
LOG D-3 / SebaFlow / TDM 300 Downloading The following is needed: update files Computer with USB interface and internet access A USB stick Proceed as follows: ► Visit www.sebakmt.com and search for the current firmware for the corresponding device type. ► Download the firmware to the computer. If it is a packed directory with the extension .zip, unpack it. The name of the required firmware file ends with .ld3 ► Connect the USB stick to the computer.
LOG DX / TDM 200 7 LOG DX / TDM 200 Here you can find information about all functions that are available for working with LOG DX data loggers and TDM 200 devices. 7.1 Managing devices in PS-3 Each logger and device to be contacted must be logged into PocketServer. ► In the start screen, tap LOG DX / TDM 200. The menu of the same name opens. Display area The display area is divided into two areas. In the Function section you will find the functions for adding devices.
LOG DX / TDM 200 ► In the Devices section, select the corresponding device. ► Answer the confirmation prompt with OK. The device disappears from the device list. All data of the device are deleted from the PocketServer. ► Tap the button 7.2 . Reading the measured data To read out the measured data from the device, proceed as follows: ► In the start screen, tap LOG DX / TDM 200. ► Select the desired device from the Devices list. ► Tap Measurement data.
LOG DX / TDM 200 Up to four curves can be seen: Blue Red Green Orange … Measuring channel 1 … Measuring channel 2 … Measuring channel 3 … Measuring channel 4 Hiding a curve You can hide any of the curves in the diagram view. ► Click on the corresponding coloured rectangle under the diagram. To show it again, tap on the same rectangle. Zoom You can narrow the chart view to any time range. Option 1: ► Touch a point on the diagram and slide your finger to the side to highlight the desired area.
LOG DX / TDM 200 Metadata You can display additional information about this data record. ► Tap the button . ► In the context menu, tap File info. Above the diagram, a new area opens in which the data are listed. ► To hide, tap again on 7.4 button and then on Hide info. Reading out a configuration To read out the current programming of the logger/device, proceed as follows: ► In the start screen, tap LOG DX / TDM 200. ► Select the desired device from the Devices list. ► Tap Settings.
LOG DX / TDM 200 Measurement settings Interval Currently set measurement interval The Channel 1 to Channel 4 drop-down menus show which measurement channels are activated and which sensor settings have been made. The Alarm input 1 and Alarm input 2 drop-down menus show whether alarmtriggering devices are connected. GSM settings GSM active indicates whether or not the GSM function of the device is activated. Below are the GSM settings that were made when programming the device.
LOG DX / TDM 200 The largest measurement value per measuring channel is specified by Max value. The smallest measurement value per measuring channel is specified by Min value. The total flow quantity of the previous night* is specified by Sum (only applies to flow measurements). At the bottom of the display are the start and end of the observed period. After closing the night value display, you will find this data record as a new entry under Data. It can be accessed and displayed there at any time.
LOG DX / TDM 200 ► Tap the Play button in the top left to resume the stopped measurement. Editing a diagram With the checkbox Val., a small table can be shown/hidden. This contains the current measurement interval and the last measured value of each measuring channel. You can touch and drag this table on the screen. You can hide curves from the diagram. To do so, tap on the corresponding coloured rectangles below the diagram. You can narrow the time range (zoom function).
LOG DX / TDM 200 ► In the PocketServer start screen, tap LOG DX / TDM 200. ► Select the desired device from the Devices list. ► Tap the button . ► In the context menu, tap GPS. The GPS coordinates of the mobile device are determined and displayed in a dialogue window. This may take some time. Tap OK to confirm and to save the displayed data in the PocketServer for the respective device. If no coordinates can be determined, an error message appears. 7.
LOG DX / TDM 200 Sensor Select the connected sensor type from the list. Most other parameters are inserted automatically If the correct type is not in the list, select User defined. Type Select the type of input signal from the list (voltage, pulse, etc.) Unit Select the measuring unit for the measurements. Conversion Provide information on converting signal input values in output measurements.
LOG DX / TDM 200 Internet settings (APN) Enter the data required for internet access (server address, DNS1, DNS2, user name, password). FTP active checkbox Should data transfer between the device and FTP server be possible? FTP function activated FTP function deactivated When this checkbox is deactivated, the device cannot upload data to an FTP server or download data from one.
LOG DX / TDM 200 E-mail settings Enter the credentials for the sending e-mail account (sender identification, server address, port, domain, user name, password). SMS active checkbox Should SMS notifications be issued? SMS possible SMS not possible When this checkbox is deactivated, it is not possible for the device to send alarm or status messages via SMS.
LOG DX / TDM 200 Option 3: Exporting a To copy the measured data of an individual measurement from PocketServer to the measurement USB stick, proceed as follows: ► Select the desired device from the Devices list. ► Select the desired data record from the Data list. ► Tap the button . ► In the context menu, tap Export. The data is transmitted. A success message appears at the end of the operation.
LOG DX / TDM 200 ► In the second list, select the device to be updated. ► Tap Install. The update begins! NOTE Do not interrupt the process. Do not make any entries until the update is complete. The connection between PocketServer and device is established. The firmware data is transmitted. The wireless LED of the PocketServer lights up blue. The status LED on the device lights up blue/white. Progress of the procedure is displayed on the screen.
PS-3 – Status & settings PS-3 – Status & settings 8 Here you can find information about the PocketServer system settings. You can access the System settings menu at any time by pressing the button 8.1 . Device info To obtain general information on the device and current status information … ► tap in the system settings menus on Device info.
PS-3 – Status & settings Correlator Displays whether the PocketServer is enabled for the correlation of measurements. … enabled … not enabled Network Displays whether the PocketServer is enabled for managing device networks. … enabled … not enabled Time/Date Displays the time and date currently set in PocketServer. 8.2 Settings Various system settings can be customised by the user. 8.2.1 Language You can change the operating language of the PocketServer user interface.
PS-3 – Status & settings display without removing an older value from the display. Alternatively, it can be set to display only the last 10, 20, 50 or 100 readings in the diagram. ► Tap in the system settings menus on Settings. ► Tap Real-time display. ► Select the desired number from the drop-down list and confirm with OK. Example: If you select the option Show all, each new recorded value will be added to the diagram. All values of the running real-time measurement can be seen in the diagram.
PS-3 – Exporting all data 9 PS-3 – Exporting all data You can connect a USB data store to the PocketServer and copy all data in the device to it. From the USB stick, the data can then be imported to the SebaDataView-3 software. ► Connect the USB stick to the PocketServer. ► Tap the button . ► Tap USB. ► Tap Export. The data is transmitted. A success message appears at the end of the operation. To safely remove the USB stick from the PocketServer, follow these steps: ► Tap the button . ► Tap USB.
PS-3 – Firmware update 10 PS-3 – Firmware update SebaKMT provides regularly updated versions of the firmware at www.sebakmt.com for all devices. Check and update regularly the firmware of your devices. Identifying the In order to determine which firmware version is currently installed on PocketServer, firmware version proceed as follows: ► Tap the button . ► Tap Device info. ► Tap Software. The firmware version is shown in the Firmware section.
PS-3 – Firmware update Safely removing the To safely remove the USB stick from the PocketServer, follow these steps: USB device ► Tap the button . ► Tap USB. ► Tap Remove USB device. You can now remove the USB stick.
PS-3 – Firmware update Tento symbol indikuje, že výrobek nesoucí takovéto označení nelze likvidovat společně s běžným domovním odpadem. Jelikož se jedná o produkt obchodovaný mezi podnikatelskými subjekty (B2B), nelze jej likvidovat ani ve veřejných sběrných dvorech. Pokud se potřebujete tohoto výrobku zbavit, obraťte se na organizaci specializující se na likvidaci starých elektrických spotřebičů v blízkosti svého působiště.