Consultation with SebaKMT User Manual Correlator COR C-300-RI Mess- und Ortungstechnik Measuring and Locating Technologies Elektrizitätsnetze Power Networks Kommunikationsnetze Communication Networks Rohrleitungsnetze Water Networks Abwassernetze Sewer Systems Leitungsortung Line Locating Issue: Article number: 1 0.
Consultation with SebaKMT 2
Consultation with SebaKMT Consultation with SebaKMT The present system manual has been designed as an operating guide and for reference. It is meant to answer your questions and solve your problems in as fast and easy a way as possible. Please start with referring to this manual should any trouble occur. In doing so, make use of the table of contents and read the relevant paragraph with great attention. Furthermore, check all terminals and connections of the instruments involved.
Terms of Warranty Terms of Warranty SebaKMT accept responsibility for a claim under warranty brought forward by a customer for a product sold by SebaKMT under the terms stated below. SebaKMT warrant that at the time of delivery SebaKMT products are free from manufacturing or material defects which might considerably reduce their value or usability. This warranty does not apply to faults in the software supplied.
Terms of Warranty Contents Consultation with SebaKMT ...........................................................................................3 Terms of Warranty ...........................................................................................................4 1 Safety Instructions ...........................................................................................8 1.1 General Safety Instructions and Warnings.........................................................8 1.
Terms of Warranty 6.6 6.6.1 6.6.2 6.6.3 6.6.4 Correlation ........................................................................................................31 Perform and display a correlation ....................................................................31 Display and select audio blocks (Offline measurements only).........................32 Call up the correlation analysis menu ..............................................................
Terms of Warranty 7
Safety Instructions 1 Safety Instructions 1.1 General Safety Instructions and Warnings • • • • • • 1.2 Do not drop the device / the system’s components or subject it / them to strong impacts or mechanical shocks. The limits described under Technical Data may not be exceeded. The device / system must be in a technically perfect condition for measurement. The indicated degree of protection can only be ensured if plugs or the provided protection caps are put in all sockets of the device.
Safety Instructions Use genuine accessories to ensure system safety and reliable operation. The use of other parts is not permitted and invalidates the warranty. Repair and Repair and maintenance work has to be carried out by SebaKMT or authorised service maintenance partners using original spare parts only. SebaKMT recommends having the system tested and maintained at a SebaKMT service centre once a year. SebaKMT also offers its customers on-site service. Please contact your service centre if needed.
Technical description 2 Technical description 2.1 Function The Correlux C-300-RI is a digital correlation system to locate leaks in drinking water pipes. Pressurized water at the leak location creates a noise which travels out in all directions of the pipe. This noise is recorded, amplified and sent wirelessly to the correlation system by two sensors (piezo microphone, hydrophone) which are attached to the pipe (e.g. valve, hydrants).
Technical description 2.
Technical description NOTE When connected to the electrical system of a car, the transport case is powered by the vehicle's battery, even while the vehicle is not in operation. This could result in the complete discharge of the vehicle battery. When you park the car, disconnect the Correlux transport case from the vehicle power supply. You can find more information in the chapters which describe the individual devices.
Technical description 2.4 Scope of delivery Standard accessory The basic set comprises the following devices and accessories: Accessory Description Art.no. COR C-300-RI USB interface 1008480 COR PT-3A Power transmitter A 1004779 COR PT-3B Power transmitter B 1004780 PAM CORR-2 2 x active universal microphone for PT-3 820019615 LG C-3 Charging unit for CPK 3/CMK 3 1006646 LK 13 Car charging adaptor, 3.
Technical description Parameter Value Operating time min. 12 h Connections Sensor (microphone/hydrophone), Radio antenna Dimensions (without handle) Ø 125 x 111 mm Weight (without sensor) 0.
Technical description Sensor Parameter PAM CORR-2 Type Value Piezo sensor with magnetic adaptor (to be connected to Power transmitter or Correlator) Active amplification yes Dimensions Ø 38 x 78 mm Weight 0.
COR C-300-RI 3 COR C-300-RI 3.1 Function and design The COR C-300-RI is a portable device, acting as a radio interface between a PC or laptop and the sensor devices of the COR C-3 system. With the C-300-RI it is possible to program/configure the Multisensors (COR MS-3) and receive the analog signal of the Power-Transmitters (COR PT-3). The C-300-RI has two external connectors to connect two different antennas - one for digital communication and one for long range analog communication.
The Power transmitters 4 The Power transmitters 4.1 Function and Design Each Power transmitter has an active amplifier for the microphone signal, a data memory, a rechargeable Li-Ion battery, a digital radio module and an analogue radio module with antenna inside. The sensors have the following external characteristics: Element Description Microphone storage place Sensor socket for connecting the microphone / hydrophone I/O pushbutton short pressing long pressing ... switches the device on ...
The Power transmitters Indicator lights The Power transmitters have the following lights (LEDs): Element Description LED bar lit green lit red ... represents the current battery level ... represents the noise level I/O LED lit green flashing not lit ... the transmitter is switched on ... the device is charging ... the transmitter is switched off Radio LED lit red ... the transmitter is in "Active" mode, noise measurement in progress, measurement data is being sent to the Correlator not lit ...
The Power transmitters 4.2 Identification number (ID) Each Power transmitter has its own six-digit identification number (short: ID). Using this ID the device can be managed and clearly identified in the Correlator, computer and within the SebaKMT-Cloud. The ID is deduced from the last six digits of the device's serial number (short: SN). You find the serial number on the nameplate of the device. When entering an ID on the Correlator or computer, the preceding zero digits can be omitted. 4.
The Power transmitters 4.4 Commissioning Switching ON/OFF To turn on, briefly press the I/O pushbutton . The I/O LED is lit green when the device is turned on. To turn the device off, press the button until the LED goes out. Stand-by The microphone's storage place is fitted with a magnetic switch. As a result, the Power transmitter "knows" whether the microphone is currently in use or not. As long as the microphone rests in its storage place, the Power transmitter remains in "Stand-by" mode.
The Multi sensors 5 The Multi sensors 5.1 Design and function Each Multi sensor has a highly sensitive piezo microphone with active amplifier, a data memory, a rechargeable Li-Ion battery and a radio module with antenna inside. The sensors have the following external characteristics: Element Description Status LED flashes green flashes yellow flashes red flashes rapidly no light ... ... ... ... ...
The Multi sensors 5.3 Power supply Battery level The Multi sensors are fitted with internal rechargeable Li-Ion batteries This can power the device for at least 16 hours. In the Start menu of the Correlator up to eight battery icons can be seen. They indicate the current battery status of the registered Multi sensors in reach. To know the exact battery state of a Multi sensor, read the unit's configurations menu (see page Fehler! Textmarke nicht definiert.).
The Multi sensors 5.5 Installation The Multi sensors should be installed directly on the pipe However, you can also attach them to valve rods or hydrants, for example, or any other position along the pipeline that is easily accessible. Due to their powerful magnet, the sensors can also be attached horizontally. There must be the best possible contact between the sensor foot or the mounted adapter (see below) and the pipe. If need be, clean the contact point thoroughly (preferably with a wire brush). 5.
The Multi sensors 24
CorreluxView Software 6 CorreluxView Software 6.1 User interface The CorreluxView screen is divided into three sections - menu bar, directory tree and display area. This screen layout remains unchanged regardless of menu level. Menu bar Directory tree Display area Menu bar The menu bar (ribbon) allows you to access any command or function. Function keys are combined appropriately into different segments.
CorreluxView Software Display area The display area is divided into the following sections: Measurement information (name of correlation, time of measurement, measurement comments) List of sensors in use Map (at the very top: function keys for map management) Element Description Button to • edit the GPS data for this sensor • edit the comment text for this sensor Sensor number Identification number for this sensor Button for deleting this sensor from the list Button for listening to the quietest recordin
CorreluxView Software 6.2 Basic settings You should always check basic CorreluxView software settings and adjust these if necessary before using the application. To open the system settings menu, proceed as follows: Step Description 1 Click on the CorreluxView symbol 2 Click on Settings in the context menu. at the top left of the menu bar. Result: The system settings menu opens. 6.2.
CorreluxView Software 6.2.4 Logarithmic or linear coherence display In the Correlation menu a Coherence curve is shown. You can select whether the frequency axis for the coherence curve should rise linearly or logarithmically. Open the Correlation tab. Use the drop-down menu in the Coherence segment. Explanation: The frequency range of the Correlux C-300 system is from 0 to 3300 Hz. Experience shows that the frequency of leak noise ranges from 0 to 1000 Hz.
CorreluxView Software Deleting a directory To remove a directory from the directory tree, proceed as follows: Step Description 1 Select the relevant directory in the directory tree. 2 Click on Delete in the Folder segment. 3 Answer Yes to the delete confirmation prompt. Result: The directory as well as all measurements stored under that directory are deleted from the database. 6.
CorreluxView Software Arrange sensor icons To move and reposition sensor icons in the map section, proceed as follows: Step Description 1 The button 2 Click once on the sensor symbol you want to move. must be deactivated. Result: The symbol is now highlighted and "stuck" to your mouse cursor. 3 Move your mouse cursor to the new position for the symbol, then click your mouse button again. Result: The sensor now occupies the new position.
CorreluxView Software 6.6 Correlation 6.6.1 Perform and display a correlation To display the correlation result for a measurement, proceed as follows: Step Description 1 Select the relevant measurement in the directory tree. 2 Click on the Correlation button in the menu bar. 3 Result: In the case of Online measurements, a single window will appear and display the correlation result as a curve (left graphic).
CorreluxView Software 6.6.2 Display and select audio blocks (Offline measurements only) Show audio blocks Once you click on the thumbnail of a sensor pair, 10 additional thumbnails will open at the right of the screen, showing the individual correlations of the 10 audio blocks recorded by these two sensors during measurement.
CorreluxView Software 6.6.3 Call up the correlation analysis menu Call up analysis menu Once you click twice on a correlation displayed by CorreluxView, the analysis menu appears which can be used to more closely examine the correlation. Design The menu which opens is very similar to the Correlator's Correlation menu.
CorreluxView Software Automatic search for filter … Provides 10 possible filter settings for selection Click on the button. The application will open a window which suggests 10 possible frequency filter settings, with the most sensible highlighted. Bandpass … To delimit a frequency range The button must first be activated. Then go to the coherence diagram and select your desired frequency range. The correlation is updated, suppressing those frequencies which fall outside the range you selected.
CorreluxView Software Tento symbol indikuje, že výrobek nesoucí takovéto označení nelze likvidovat společně s běžným domovním odpadem. Jelikož se jedná o produkt obchodovaný mezi podnikatelskými subjekty (B2B), nelze jej likvidovat ani ve veřejných sběrných dvorech. Pokud se potřebujete tohoto výrobku zbavit, obraťte se na organizaci specializující se na likvidaci starých elektrických spotřebičů v blízkosti svého působiště.