ELITERAID ER104UT+(B) DETAILED USER’S MANUAL v1.
TABLE OF CONTENTS 1 WELCOME .......................................................................................................................................................4 1.1 1.2 1.3 1.3.1 1.3.2 1.3.3 1.4 1.5 1.5.1 1.5.2 1.6 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3 INTRODUCTION........................................................................................................................................4 PRECAUTION..............................................................................
.6 REBUILDING A REDUNDANCY OR HOT SPARE DRIVE.............................................................19 3.6.1 REBUILDING A REDUNDANCY DRIVE...................................................................................................19 3.6.2 REBUILDING A HOT SPARE DRIVE..........................................................................................................19 4 PARTITIONING VOLUMES ..................................................................................................
1 WELCOME 1.1 INTRODUCTION Thank you for choosing EliteRAID ER104UT(-B) storage appliance. It is a hardware RAID solution for digital home and small office storage appliances. Features of the EliteRAID ER104UT(-B) include advanced RAID modes. Simply connect the appliance with an appropriate USB or eSATA cable to the USB host or PCIe 1x controller card. eSATA bracket cable is provided to connect to motherboard if no PCIe slot avaliable.
1.2 PRECAUTION Please read the safe precautions carefully before you using EliteRAID ER104UT(-B) storage appliance. Ensure that you use the product correctly according to the procedure described in this guide. The following safety precautions are intended to remind you to operate the product safely and correctly. Please read and ensure that you understand them before you proceed to the other sections of this guide. z Do not plug any HDD(s) while power is on (except operation in CLEAN MODE).
z 1 host port (eSATA or USB) to 4 Serial ATA hard disk drives. z Compatible with SATA Gen1 and Gen2 host controllers. z Compatible SuperSpeed USB 3.0 specifications, backward compatible with USB 2.0. z Embedded fast Storage Processor. z Ultra-fast 3Gbps host and device port capability. z Greater than 200MBps sustained reads in R0 mode (limited by drives and host controller). 1.3.
1.5 SYSTEM REQUIREMENTS 1.5.1 PC SYSTEMS • Intel Pentium-III 500MHz equivalent or faster • Windows XP, Windows Vista, Windows 7 RC2 with the latest Service Packs • CD-ROM drive • 64 MB of RAM (minimum) • 250 MB of free disk space • Super VGA (800 x 600) or higher resolution display with at least 256 colors • Mouse or compatible pointing device • PCIe slot of optional PCIe eSATA controller • USB connection: USB 1.0 or 2.0 or 3.0 direct host connection or USB hub 1.5.
2 STORAGE POLICIES You can configure the EliteRAID ER104UT(-B) storage appliance to use any of the following storage policies to map the appliance’s physical hard drives to virtual drives that are visible to the host computer. The virtual drives are called volumes. The host operating system treats each volume as if it were a single physical drive. This virtualization allows you to overcome restrictions that are imposed by physical hard drives, such as speed, storage capacity or data storage reliability. 2.
ER104UT(-B) It is also possible to create a LARGE volume using only a single hard disk drive connected to Port 1. However, it is not possible to expand an existing LARGE volume by adding another hard disk drive and still preserve any existing data on that volume. 2.3 CLONE MODE The CLONE MODE storage policy stores all data in duplicate on separate drives to protect against data loss due to drive failure. One drive clones the others at all times. Every write operation goes to all drives.
ER104UT(-B) 2.4 R0 MODE The R0 MODE storage policy distributes access across all hard disks. R0 MODE presents the best data speed but no data redundancy. R0 MODE storage policy accelerates hard disk drive operating speed by using many disks in parallel. Hard disk drive data segments are written to different disks simultaneously which increases performance while sacrificing data redundancy.
Although the volume remains available during the rebuild process, the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild and verification process. Host access takes precedence over the rebuild process. If you continue to use the R1 volume during the rebuild, the rebuild process will take a longer time to complete, and the host data transfer performance will also be affected. ER104UT(-B) 2.
2.7 R3 MODE The R3 MODE storage policy requires a minimum of 3 drives to implement. The R3 MODE adds fault tolerance to drive striping by including parity information with the data. R3 MODE dedicates the equivalent of one drive for storing parity stripes. The data and parity information is arranged on the drive array so that parity is written to one drive. There are at least 3 members to a virtual R3 volume. The following example illustrates how the parity is rotated from drive to drive.
stripes. The data and parity information is arranged on the drive array so that parity is written to all drives. There are at least 3 members to a virtual R5 volume. The following example illustrates how the parity is rotated from drive to drive. The R5 MODE uses less capacity for protection and is the preferred method to reduce the cost per megabyte for larger installations. In exchange for low overhead necessary to implement protection, the R5 MODE degrades performance for all write operations.
3 CONFIGURATION 3.1 CONFIGURATION PREREQUISITES 3.1.1 SATA HOST CONNECTIONS This guide assumes that you have already attached the EliteRAID ER104UT(-B) to a host computer that has been installed with the R622 HBA (Host Bridge Adapter) or another SATA HBA with Port Multiplier (PM) support. If you use a host controller that does not provide Port Multiplier support (Such as Intel ICH): • The CLEAN MODE storage policy is unavailable when configuring the EliteRAID ER104UT(-B).
3. The following message then appears: “Safe to Remove Hardware”. You can now safely disconnect the device from your computer. Note: If your host USB adapter does not support this feature, the device should be disabled using the Device Manager or your system should be shut down cleanly and powered off before disconnecting the USB device. 3.3.2 MACINTOSH SYSTEMS You must un-mount the hard disk drive by dragging the hard drive icon to the trash before disconnecting it or powering it down. 3.
4. Turn on the power than release the SETUP BUTTON to complete mode setting. 3.5.3 CLONE MODE The CLONE MODE storage policy requires a minimum of 2 drives to implement. 1. Turn off the power. 2. Set the MODE SWITCH position to CLONE. 3. Press and hold the recessed SETUP BUTTON. 4. Turn on the power than release the SETUP BUTTON to complete mode setting. 3.5.4 CLONE MODE WITH HOT SPARE The CLONE MODE storage policy with hotspare drive requires a minimum of 3 drives to implement. 1. Turn off the power. 2.
4. Turn on the power than release the SETUP BUTTON to complete mode setting. 3.5.6 R1 MODE The R1 MODE storage policy requires 2 drives to implement. 1. Turn off the power. 2. Set the MODE SWITCH position to R1/R10. 3. Press and hold the recessed SETUP BUTTON. 4. Turn on the power than release the SETUP BUTTON to complete mode setting. 3.5.7 R1 MODE WITH HOT SPARE 1. Turn off the power. 2. Insert 3 drives in order from the top to the bottom. 3. Set the MODE SWITCH position to R1/R10. 4.
3. Press and hold the recessed SETUP BUTTON. 4. Turn on the power than release the SETUP BUTTON to complete mode setting. 3.5.10 R3 MODE WITH HOT SPARE The R3 MODE storage policy with hotspare drive requires a minimum of 4 drives to implement. 1. Turn off the power. 2. Insert 3 drives in order from the top to the bottom. 3. Set the MODE SWITCH position to R3. 4. Press and hold the recessed SETUP BUTTON. 5. Turn on the power than release the SETUP BUTTON. 6. Turn off the power. 7.
4. Press and hold the recessed SETUP BUTTON. 5. Turn on the power than release the SETUP BUTTON. 6. Turn off the power. 7. Insert the hotspare drive into the 4th HDD bay. 8. Turn on the power to complete mode setting. 3.6 REBUILDING A REDUNDANCY OR HOT SPARE DRIVE The EliteRAID ER104UT(-B) storage appliance stores all data in duplicate on separate drives to protect against data loss due to drive failure on CLONE, R1, R3, R5, and R10 MODE.
4 PARTITIONING VOLUMES 4.1 PARTITION A VOLUME 4.1.1 WINDOWS SYSTEMS Note: Before repartition a volume, back up your data and delete previously defined partitions. 1. Right-click the My Computer icon on your desktop and select Manage from the pop-up window. 2. Select Disk Management under Storage to open the Windows Disk Manager. This example illustrates the LARGE storage policy, which concatenates the capacity of all hard drives connected to the TERA BOX SATA RAID III.
checked and click OK. The disk should now be marked as a Basic disk. If a disk appears as “Dynamic”, right-click the disk icon, and select Revert to Basic Disk. Within a few seconds, the disk should be marked as a Basic disk. If a disk is marked “Not Initialized”, right-click the disk icon and select Initialize Disk. An additional dialog box appears allowing you to select which disks to initialize. Uncheck the SteelVine Processor Disk item and click OK.
4. Click Next to start the Partition Wizard. 5. Select the Primary or Extended option and click Next.
6. Specify the partition size. By default, the partition occupies the entire volume. Click Next. 7. Assign a drive letter or mount path and click Next.
8. Name and format the partition and click Next. 9. Review the file system settings and click Finish to create the logical partition.
10. Repeat steps 1 through 9 to partition any remaining disks. 4.1.2 MACINTOSH SYSTEMS Note: Before reconfiguring a volume, back up your data and drag the old drive to the trash to un-mount previously partition. After you configure and partition the new volumes, restore the backed-up data to the new configuration. 1. Launch Disk Utility from the Application > Utilities folder.
2. Select a configured disk and click the Partition tab. This procedure illustrates the LARGE Storage Policy configuration, which concatenates the capacity of all hard drives connected to the TERA BOX SATA RAID III. 3. Select 1 Partition from the Volume Scheme drop-down list. 4. Enter a name for the volume in the Name field (such as “My Disk”.) 5. Select Mac OS Extended (journaled) from the Format drop-down list. 6. Specify the size of the partition in the Size field. 7. Click the Partition button. 8.
Disk Utility mounts the created partition and represents it with an icon on the desktop. The icon is labeled with the partition name. 9. Repeat steps 1 through 8 to partition any remaining disks you configured.
5 APPENDIX 5.1 FAQ If you need some help for troubleshooting, please check the frequently asked question below, it may help you problem solved quickly z Can not recognize .Make sure all cables have been connected properly. z Can not operate in O/S .Make sure the O/S is support for the product. z Transmission speed is slow .If connect USB1.1 interface, the speed will be around 1MB/sec only.
Maxtor Maxtor Maxtor Maxtor Maxtor Maxtor Maxtor Maxtor Samsung Samsung Samsung Samsung Samsung Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate Seagate 2.5” Toshiba 2.5” Toshiba 2.5” Toshiba 2.5” Toshiba SSD 2.
160GB Western Digital Western Digital 160GB Western Digital 150GB Western Digital 100GB Western Digital 80GB Western Digital 80GB Table last updated October 2009. 5.3 WD Caviar® Blue WD Caviar® Blue WD Caviar® Blue WD Scorpio ® Blue WD Caviar® Blue WD Caviar® SE WD1600AAJS-22PSA0 WD1600JS-22MHB0 WD1500AHFD-00RAR0 WD1000BEVS-22LAT0 WD800AAJS-00PSA0 WD800JD-00M8A1 05.06H05 02.010C3 19.06P19 01.06M01 D5.06H05 10.