Installation Guide

Installation And Safety Instructions
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to
this fixture. Fill in Item Number on Carton and File This Sheet For Future Reference. ITEM#_______________
HC-1610
0
72909
Caution! The following rules must be adhered to when installing light
fixtures. Failure to comply with these requirements could lead to an
electrical shock or fire which could be injurious or even fatal. Make
certain:
1) To disconnect power at main fuse box before installing fixture.
2) The ground wire (bare or green insulated wire) is not connected to
current carrying supply wires.
3) No bare wires are exposed outside of connectors when connecting
current carrying fixture wires to current carrying house wires.
4) The insulation on fixture wires has not been damaged during
installation.
5) No rough or sharp edges of any surface are in contact with wires.
6 Fixture supply wires are connected to proper house supply wires.
7) To use light bulbs with wattages no greater than specified for the
fixture.
Warning: for fixtures provided with 75°C or 90°C supply wire warning
only (these warnings are provided on the label and on the fixture carton).
Warning: Risk of fire. Most dwellings built before 1985 have supply wire
rated 60°C. Consult a qualified electrician before installing.
If you have any doubts about how to install a light fixture or it fails to
operate properly, contact a local licensed electrician.
By passing the socket bracket stop may cause the light to cycle on and
off or nuisance trip.
IMPORTANT SAFETY INSTRUCTIONS
(1) CUTTING A HOLE
Locate the center of proposed opening on your tile or ceiling
material and mark it. Use the template provided to draw a 6 3/8"
dia. circle around the center point. Cut along the circular line.
(2) ELECTRICAL CONNECTION
Junction box contains two wires, a black (hot) and white (neutral)
which must be spliced to the house wires. MAKE SURE TO
SPLICE WHITE TO WHITE AND COLORED OR BLACK TO
BLACK. After splicing has been completed, insert wires carefully
into junction box. Connect green ground wire to green grounding
pigtail in junction box (see Drawing A). Replace cover.
(3) INSTALLING FIXTURE TO CEILING
Slip outlet box, then housing through hole in ceiling. Install (3)
clips through “T” slots in housing (Drawing C). Make sure clips
are completely extended from housing so fixture is supported in
ceiling (Drawing D).
(4)
INST
ALL TRIM ASSEMBLIES
(5)
BALLAST REPLACEMENT
(a)
To replace the ballast, disconnect the power to 11088LE at
the br
eaker panel.
(b) Access integral junction box and undo wir
e connections
between ballast and housing.
(c) Remove screws that secure ballast to junction box.
(d) Make wiring connections between replacement ballast and
housing. Use scr
ews to attach ballast to junction box.
(e) Replace trim. Connect power to 11088LE at panel.
11088 IC REMODEL HOUSING FOR DIRECT CONTACT
WITH INSULATION
A
B
C
D
POWER
LEAD
GROUND
CLIP
“T” SLOT
CLIPS
Hg
MARK MEANS LAMP CONT
AINS MERCUR
Y
.
FOLLOW DISPOSAL LAWS.