ConneXions CONX8E/3 RS232 Radio Paging System (Triple Port, Mains Euro Version) Installation & User Manual ConneXions II Scope Communications UK Ltd, Quantum House, Steamer Quay, Totnes TQ9 5AL, England, UK Tel: +44 1803 860700 Fax: +44 1803 863716 E-Mail: sales@scope-uk.com Web: www.scope-uk.
ConneXions II V8 (Euro), Multi Port Version PREFACE Important Installation Information It is the purchasers’ responsibility to determine the suitability of this equipment and its derivatives for any given application, Scope cannot give specific advice in this manual, as each use will require independent evaluation. Scope has, wherever possible, employed extra safeguards to monitor the system’s performance.
ConneXions II V8 (Euro), Multi Port Version Preface Installation Installation must only be undertaken by an Approved contractor, who shall ensure that all work is carried out in compliance with National Wiring Regulations. For mains powered equipment, a readily accessible isolating fuse or switched socket must be located within 1 metre of the equipment.
ConneXions II V8 (Euro), Multi Port Version System Overview The Scope ConneXions II V8 (Euro) is a POCSAG data display radio paging system which can be used to transmit both text and numeric messages direct to pocket pagers carried by individuals or entire groups. Information is input by way of three RS232 serial ports. The unit can also be used in conjunction with an optional telephone interface, thereby enabling any telephone within the building or complex of buildings to access the paging system.
ConneXions II V8 (Euro), Multi Port Version Some major points to consider when installing equipment: 1 Never install antennas near or adjacent to telephone, public address or data communication lines or overhead power cables. 2 Avoid, where ever possible, running antenna coax alongside other cables. 3 Avoid mounting the transmitter in the immediate vicinity of telephone exchanges or computer equipment. 4 Always use proprietary 50 ohm coaxial cable between the antenna and the transmitter.
ConneXions II V8 (Euro), Multi Port Version Installation The following procedure must be adhered to when installing the ConneXions paging system. Ensure you have taken into consideration all of the above information before selecting the location for your transmitter. If in doubt please feel free to telephone the technical helpline on (01803) 860710. 1 Remove the cover from the ConneXions II transmitter unit by slackening the four Pozi head screws located at the top and bottom of the unit (see Diagram 1).
ConneXions II V8 (Euro), Multi Port Version Note: the default comms Baud rate settings are as follows: PL3 = 9600 Baud PL1 and PL2 = 1200 Baud (these are factory set in software and are not hardware adjustable) PL1 OPTIONAL (10) DRY CONTACTS PIN 21 9 13 25 12 24 11 23 10 22 DESCRIPTION DRY CONTACT NO. 1 DRY CONTACT NO. 2 DRY CONTACT NO. 3 DRY CONTACT NO. 4 DRY CONTACT NO. 5 DRY CONTACT NO. 6 DRY CONTACT NO. 7 DRY CONTACT NO. 8 DRY CONTACT NO. 9 DRY CONTACT NO.
ConneXions II V8 (Euro), Multi Port Version CONX8E/3 Issue 3 7
ConneXions II V8 (Euro), Multi Port Version Section 2: System Operation Confirmation of power connection is by way of the red LED on the base of the transcoder console. Confirmation of transmit is provided by way of the momentary green LED on the base of the transcoder console. Sending data in the correct format (see Technical Section, Calling Pagers) will invoke transmitted messages to the relevant pagers. Problems and Fault Finding. 1 Check and re-check the data cable connections.
ConneXions II V8 (Euro), Multi Port Version Other Antennas The range and performance of this equipment can be improved by the addition of more efficient antennas*. These can be installed either inside or outside the building and are connected to the transmitter with 50 OHM coaxial cable. Glass mount antenna (UHFGM): for installation on the inside of a suitable window. This can boost range, especially if it is required in one direction from the building.
ConneXions II V8 (Euro), Multi Port Version System Specification Mains Input: 230V 50Hz Mains Power Consumption: 6W max System Operating Voltage: 13.8V dc System Power Consumption: less than 50mA standby, 300mA (transmit) Transmitter: Power output: 500mW Frequency Range: 450-470 MHz Channel Spacing: 25 KHz or 12.5KHz Adjacent Channel: better than 200nW @ 4.5 KHz deviation TX Baud Rate: 512 or 1200 RF Standards applied: ETS 300 224 Notified Body Ref.
ConneXions II V8 (Euro), Multi Port Version Section 3: Technical Information This section provides a more in depth understanding of how messages are formatted for serial communication from a host. It need only be studied by those intending to write their own serial comm.’s software. Calling Pagers Pagers all use 7 digit numeric addresses which enables the system to support thousands of pagers without identity clashes.
ConneXions II V8 (Euro), Multi Port Version Section 3: Technical Information Next follows the 7 digit pager identity number. All seven digits must be used. The letter following the identity is the beep type of which there are four valid characters, A, B, C or D. Next follows the message to be transmitted, which can include: 0-9, space, -(hyphen), ‘U’ (letter U for ‘U’rgent), [,] open/close square brackets, (open square brackets can also be used to identify the letter ‘C’ for ‘C’ancel).