Conext™ Gateway Conext Gateway Owner's Guide 975-0806-01-01 January 2019 http://solar.schneider-electric.
Copyright © 2019 Schneider Electric. All Rights Reserved. Google Chrome, Microsoft, Windows, and Internet Explorer used with permission from Microsoft. Safari and Mac OS are trademarks of Apple Inc., registered in the U.S. and other countries. All other trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Safety Information Important Information Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
Product Safety Information DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, ARC FLASH, AND FIRE n Read all instructions, cautionary markings, and all other appropriate sections of this guide before installing, operating, troubleshooting or performing maintenance on the Conext Gateway. n Exercise extreme caution at all times to prevent accidents. n These instructions are for use by qualified installers only. Failure to follow these instructions will result in death or serious injury.
NOTICE EQUIPMENT DAMAGE n All cables connected to the Conext Gateway must run indoors and not be susceptible to lightning strikes. n Turn OFF all devices before connecting cables. The Conext Gateway does not have an ON/OFF switch. n Do not connect an Ethernet cable from the Conext Gateway to the WAN/MODEM port on the network router. n Do not connect an Ethernet cable plug into a Xanbus port on the Conext Gateway.
Audience This guide is intended for use by anyone who plans to install and operate the Conext Gateway communications device as part of their power plant system. Installation instructions are meant for installers only. The installers have training, knowledge, and experience in: n Installing electrical equipment. n Applying all applicable installation codes. n Analyzing and reducing the hazards involved in performing electrical work. n Selecting and using Personal Protective Equipment (PPE).
About Purpose The purpose of this Owner's Guide is to provide explanations and procedures for installing, operating, configuring, maintaining, and troubleshooting the Conext Gateway. Scope The Owner's Guide provides safety guidelines, planning, and setup information, procedures for installing the product, as well as information about troubleshooting the product. It does not include information on how to install, configure and use other Schneider Electric products.
01-01) n Conext Battery Monitor Owner's Manual (part number: 975-0691-01-01) Related Information You can find more information about Schneider Electric's Solar products, as well as its services at http://solar.schneider-electric.com/.
Contents Safety Information Audience About 2 5 6 Purpose 6 Scope 6 Firmware Revision 6 Abbreviations and Acronyms 6 Related Products 6 Related Information 7 Overview 10 Introduction 11 Compatible Xanbus™ Components 11 Material List 12 Physical Features 13 Power Button Operation 14 LED Indicator Operation 14 26-pin Connector Pinouts 15 Types of Conext Gateway Networks 16 Power Sources for the Conext Gateway 16 Conext Gateway Web User Interface 17 Installation 20 Choosing
Changing Conext Gateway Settings 37 Plant Setup 38 Time Setup 38 Import and Export Settings 39 Units 40 Modbus Settings 40 Restarting the Conext Gateway 41 Install Package 42 Changing Device Settings 43 Upgrading Firmware 45 Installing Conext Gateway Upgrades From a USB Drive 45 Installing Conext Gateway Upgrades Remotely 46 Upgrading Other Device Firmware 46 Monitoring Monitoring LED Indicators Startup Monitoring the Power Plant Troubleshooting Events Specifications 48 49 49 49
Overview Conext Gateway Conext Gateway Owner's Guide 1 Overview What's in This Chapter? Introduction 11 Compatible Xanbus™ Components 11 Material List 12 Physical Features 13 Power Button Operation 14 LED Indicator Operation 14 26-pin Connector Pinouts 15 Types of Conext Gateway Networks 16 Power Sources for the Conext Gateway 16 Conext Gateway Web User Interface 17
Conext Gateway Conext Gateway Owner's Guide Overview Introduction The Conext Gateway is a multi-function communication device that provides an overall view of system performance for residential power monitoring systems. It also provides a communications gateway between a network of Xanbus™-enabled devices and Modbus devices. Operators can configure the Conext Gateway system and monitor performance with third party software packages and building management systems.
Overview Conext Gateway Conext Gateway Owner's Guide For details on specific models supported, see Specifications on page 1. The Conext Gateway supports up to a maximum of 20 devices on a Xanbus network depending on the device types. Material List Figure 1 Material list 1 Attach the antennas before turning on the unit. 3 2 4 NOTE: 975-0806-01-01 n Do not discard the packaging box. n The Wi-Fi password is printed on the unit. n Install the antennas before turning on the unit.
Conext Gateway Conext Gateway Owner's Guide Overview Physical Features The following illustration shows the Conext Gateway. The tables in the following sections contain descriptions of the connectors, indicators, and data ports on the Conext Gateway.
Overview Conext Gateway Conext Gateway Owner's Guide Power Button Operation Table 1 Power button operation Press and hold Number of Conext Gateway operation duration beeps 3 seconds 1 Conext Gateway will restart 6 seconds 2 Conext Gateway will shutdown 9 seconds 3 12 seconds 4 User settings will be reset and Conext Gateway will restart Factory default settings will be reset and Conext Gateway will restart LED Indicator Operation Figure 3 LED indicators Green Power The Conext Gateway is po
Conext Gateway Conext Gateway Owner's Guide Overview 26-pin Connector Pinouts Figure 4 26-pin connector Bottom Row Top Row 2 9–24VDC power input 1 GND 4 GND 3 0–10VDC analog input 1 6 12VDC digital input 1 5 0–10VDC analog input 2 8 12VDC digital input 2 7 GND 9 4–20mA input 1 10 ISO1 CAN GND 12 ISO1 CAN L 14 ISO1 CAN H 16 ISO2 RS485 GND 18 ISO2 RS485 1A 20 ISO2 RS485 1B 1 3 5 7 9 11 13 15 17 19 21 23 25 2 4 6 8 10 12 14 16 18 20 22 24 26 11 4–20mA input 2 13 GND 15 Relay 1 NO 17 Rel
Overview Conext Gateway Conext Gateway Owner's Guide Types of Conext Gateway Networks The Conext Gateway can interface with different LAN devices using wired or wireless connections, so you can configure your Xanbus devices and monitor your power system performance.
Conext Gateway Conext Gateway Owner's Guide Overview In the Conext Gateway, the SELV circuits and their intended connections are: n The supplied AC/DC power adapter connected to the power port of the Conext Gateway. n Xanbus communications and power which come from SELV circuits on Xanbusenabled Schneider products. n 9–24 V DC power input connections which must be SELV and are connected to the Conext Gateway via the 26-pin connector.
Overview Conext Gateway Conext Gateway Owner's Guide Figure 5 Web user interface 1 Main menu bar – displays major menu items including the Dashboard, Devices, Events, and Setup commands. It includes About, which shows Conext Gateway device information. 2 Sub-menu tabs – displays sub-menu items expanding commands associated with the major menu items. 3 Main display area 4 Web app version and build number 5 Information bar – displays the system date, time, and user type.
Installation Conext Gateway Conext Gateway Owner's Guide 2 Installation What's in This Chapter? Choosing a Location 21 Materials and Tools Required 22 Mounting the Conext Gateway 23 Wall Mount 23 DIN Rail Mount 23 Connecting the Conext Gateway to the Xanbus Network 24 Connecting the Conext Gateway to the Internet 26 Turning On the Conext Gateway 28 Turning Off the Conext Gateway 29 Power Cycling 29
Conext Gateway Conext Gateway Owner's Guide Installation Choosing a Location Figure 6 Location choices 50mm 50mm n Choose a clean, dry, easily accessible location indoors. n If you mount the Conext Gateway on a wall, the recommended height is at eyelevel so that you can clearly see the LED indicators and have easy access to the data and communication ports. n All of the ports on the Conext Gateway are accessible from the sides of the device when mounted on a wall or DIN rail.
Installation Conext Gateway Conext Gateway Owner's Guide Materials and Tools Required The following materials are supplied in the Conext Conext Gateway package: n One Conext Gateway unit n One Conext Gateway Quickstart Guide n One AC/DC power supply adapter n One 8 GB micro SD card n One CAT5e Ethernet cable (7-ft) n One 26-pin connector n One 75 mm DIN rail The following materials and tools are not supplied but are required to complete the installation: 975-0806-01-01 n CAT5e Ethernet ca
Conext Gateway Conext Gateway Owner's Guide Installation Mounting the Conext Gateway Wall Mount To mount the Conext Gateway on a wall: 1. Choose the location for mounting the device. 2. Using the diagram in the Conext Gateway Quickstart Guide (part number: 975-080401-01), mark the mounting holes on the wall with a pencil. 3. The holes must be at the same height and 4 7/16 inches (112 mm) apart. 4.
Installation Conext Gateway Conext Gateway Owner's Guide Connecting the Conext Gateway to the Xanbus Network To connect the Conext Gateway to the Xanbus network: 1. Connect the Conext Gateway to the Xanbus network using daisy chain confguration. a. Xanbus components can be arranged in any order. b. The left connectors are Xanbus 1 and the right connectors are Xanbus 2. c. Do not connect two end devices together to form a closed loop configuration. 2. Use a network terminator at both ends of the network.
Conext Gateway Conext Gateway Owner's Guide Installation Conext 1 Gateway unit Figure 7 Sample Xanbus network 2 Xanbus1 Xanbus2 3 2 3 Conext XW Pro MPPT 80 600 Conext AGS 4 (automatic generator start) 1 5 6 Conext SCP 4 5 6 (system control panel) 6 Network terminators NOTE: This Xanbus 1 network is for illustration purpose only.
Installation Conext Gateway Conext Gateway Owner's Guide Connecting the Conext Gateway to the Internet Before connecting a computer and router to the Conext Gateway, make sure it meets the following prerequisites. n Microsoft® Windows® 7 or later n Mac OS® X 10.4.8. or later n Google Chrome™ 34.x or later n Microsoft® Windows® Internet Explorer® 10.x or later n Safari® 5.x or later n JavaScript and cookies must be enabled in your web browser.
Conext Gateway Conext Gateway Owner's Guide Installation Figure 8 Ethernet connection (LAN) 2 1 MODEM 3 LAN 4 27 1 Router/modem 2 Laptop 3 Conext Gateway unit 4 Ethernet cables 975-0806-01-01
Installation Conext Gateway Conext Gateway Owner's Guide Turning On the Conext Gateway Before turning on the Conext XW+, you must connect it to a power source. Figure 9 Power connections and button Xanbus [B] [A] [C] 26-pin connector NOTE: In the 26-pin connector, pin 1 connects to a 9-24VDC source and pin 2 connects to GND Power input. See " 26-pin connector" on page 15. To turn on the Conext Gateway: 1. Select a power source to the Conext Gateway. You can choose either of the following: a.
Conext Gateway Conext Gateway Owner's Guide Installation WARNING PHYSICAL INJURY HAZARD Xanbus is a valid power source for the Conext Gateway. However, for the first time set-up, using Xanbus as a power source is not recommended. the Conext Gateway clock will override the other Xanbus devices’ clocks and could trigger unintentional time-based events. Therefore, DO NOT connect the Conext Gateway to the Xanbus network prior to setting up the internal clock of the Conext Gateway.
Configuration Conext Gateway Conext Gateway Owner's Guide 3 Configuration What's in This Chapter? Using the Conext Gateway Web App via Wi-Fi Access Point (AP) 31 Web Security 32 Configuring the Conext Gateway 32 Logging in to the Conext Gateway Web Application 34 Changing the Password 35 Changing Conext Gateway Settings 37 Plant Setup 38 Time Setup 38 Import and Export Settings 39 Units 40 Modbus Settings 40 Restarting the Conext Gateway Install Package 41 42 Changing Device Sett
Conext Gateway Conext Gateway Owner's Guide Configuration Using the Conext Gateway Web App via Wi-Fi Access Point (AP) NOTE: This procedure is not about connecting to a local area network (LAN) via Wi-Fi. In order to establish a user interface with Conext Gateway, a direct Wi-Fi connection is necessary. The following are the pre-requisites: n Laptop with Microsoft® Windows® 7 or later, Mac OS® X 10.4.8. or later n Wi-Fi setting for the laptop is enabled n Web browser such as Google Chrome™ 34.
Configuration Conext Gateway Conext Gateway Owner's Guide 3. Open Wi-Fi Settings, then look for and connect to the Conext Gateway SSID. For example, you may look for something similar to ConextGateway_fe808b below. 4. Enter the Password when prompted. NOTE: The password is printed on a label on the back panel of the Conext Gateway unit. 5. Proceed to Logging in to the Conext Gateway Web Application.
Conext Gateway Conext Gateway Owner's Guide Configuration 3. Set plant site information - see "Plant Setup" on page 38 4. Set the system time - see "Time Setup" on page 38 Optional/Occasional 1. Configure general device settings - see "Changing Device Settings" on page 43 2.
Configuration Conext Gateway Conext Gateway Owner's Guide Logging in to the Conext Gateway Web Application 1. If you have connected the Conext Gateway via Wi-Fi, go to the IP address https://191.168.100.1 to access the web user interface. 2. If you have connected the Conext Gateway via Ethernet use the following steps: a. Insert a blank USB drive into the Conext Gateway USB port. Ensure there are no firmware upgrade files on this USB drive. b. After the Conext Gateway beeps twice, remove the USB drive. c.
Conext Gateway Conext Gateway Owner's Guide Configuration 6. Change the Conext Gateway SSID and network password. a. Go to Setup > Network > Wifi Access Point Settings b. (Optional) Replace the current Wi-Fi network name under the SSID field with an appropriate name. You are limited to 64 alphanumeric characters including symbols. c. Replace the current password under the Password field with 10 or more alphanumeric characters including symbols. d. Click Apply to save the new password and/or SSID.
Configuration Conext Gateway Conext Gateway Owner's Guide Figure 13 Password screen n 975-0806-01-01 You may have to log in again after changing the initial password.
Conext Gateway Conext Gateway Owner's Guide Configuration To change the password after the initial log in: Figure 14 Change password setting 1. Click Setup > Manage Passwords > Change Passwords. 2. Select the User name type. Note: Admin-level can change all passwords. User-level can change User and Guest passwords. Guest-level cannot change any passwords. l Admin l User l Guest 3. Enter the Old password. 4. Enter the New password. 5. Enter the Confirm password. 6. Click Apply.
Configuration Conext Gateway Conext Gateway Owner's Guide 3. With only a few exceptions, you may save a setting by clicking Apply or ignore changes by clicking Cancel. That portion of the window expands to display the change options for that setting. The size and content of the expanded window varies depending on the setting type. Plant Setup It is recommended to name the plant site to distinguish it from other installations in your power system.
Conext Gateway Conext Gateway Owner's Guide Configuration To change the Conext Gateway time: 1. Click Setup > Configuration> Time setup. 2. Select the Time zone. This time setting overrides settings on other devices in the system. 3. Enter the date and time by clicking the calendar icon beside Date & time. 4. Click Apply. Your settings will be immediately applied.
Configuration Conext Gateway Conext Gateway Owner's Guide Units This setting allows you to change the standard unit of measurement used in solar irradiance, temperature, and wind speed. Figure 18 Units setup screen To change units: 1. In the main menu bar, click Setup > Configuration. The Configuration settings appear in the main display area. 2. Click Unit. Currently, only Temperature can be changed to either celsius or farenheit. 3. Save the settings by clicking Apply .
Conext Gateway Conext Gateway Owner's Guide Configuration To change Modbus settings: 1. In the main menu bar, click Setup > Configuration. The Configuration settings appear in the main display area. 2. Click Modbus settings. a. Select the proper Baud rate. b. Select the correct Parity. c. Select the corresponding Stop bits. 3. Save the settings by clicking Apply . Alternatively, ignore the changes by clicking Cancel.
Configuration Conext Gateway Conext Gateway Owner's Guide including forgetting all detected devices, removing data logs, removing event logs, and resetting all configuration. 3. Follow the succeeding instructions. Install Package To install a Conext Gateway upgrade remotely: 1. From the Conext Gateway Web Application home page, go to Setup > Configuration > Install Package. 2. Download the firmware package. a. Click Get package. This will take you to the Conext Gateway product webpage. b.
Conext Gateway Conext Gateway Owner's Guide Configuration Changing Device Settings Before making any changes, familiarize yourself thoroughly with the effects of changing the settings of another device. NOTICE RISK OF EQUIPMENT DAMAGE n Consult the device’s Owner’s Guide when changing the device’s settings. n Make sure the device connected on the Xanbus or Modbus network is in Standby mode before changing settings. n Do not change any settings unless you are familiar with the device.
Configuration Conext Gateway Conext Gateway Owner's Guide Figure 22 Sample Device Overview screen - List display To change a device setting: 1. In the main menu bar, click Devices. See Figure 21 for a sample of the default display of all connected devices. 2. If you want a shorter list of devices, switch to a List display. See Figure 22. 3. Put the device in to Standby mode first. a. Click a device you want to put in to Standby mode. b. Click Configuration > Controls.
Conext Gateway Conext Gateway Owner's Guide Configuration Upgrading Firmware You can perform firmware upgrades for your Conext Gateway and Xanbus-enabled devices when they are available for download.
Configuration Conext Gateway Conext Gateway Owner's Guide Installing Conext Gateway Upgrades Remotely For full instructions, see "Install Package" on page 42. Upgrading Other Device Firmware It is possible to upgrade a device's firmware through the Conext Gateway web application. NOTICE RISK OF EQUIPMENT DAMAGE n Consult the device’s Owner’s Guide when changing the device’s settings. n Make sure the device connected on the Xanbus or Modbus network is in Standby mode before changing settings.
Conext Gateway Conext Gateway Owner's Guide Configuration c. Search for the control setting Operating Mode. d. Select Standby. e. Click Apply. 3. Click Firmware . 4. Click Upgrade. 5. Follow the step-by-step upgrade instructions. 6. To upgrade all similar devices in the network, click Upgrade All. 7. Follow the step-by-step upgrade instructions. 8. Use the Operating Mode menu to put the device back into normal operating mode.
Monitoring Conext Gateway Conext Gateway Owner's Guide 4 Monitoring What's in This Chapter? Monitoring LED Indicators Startup Monitoring the Power Plant 49 49 49
Conext Gateway Conext Gateway Owner's Guide Monitoring Monitoring LED Indicators LED indicators allow you to monitor the functioning of the Conext Gateway. Table 2 LED indicators Icon Color LED Green Power Green Memory Green Cloud Green Xanbus Green Modbus Red Event Blue Wi-Fi C X M ! Description The Conext Gateway is powered and ready to communicate when on. Device is logging data to internal memory when flashing. Device is actively transferring data with a communication device/s.
Monitoring Conext Gateway Conext Gateway Owner's Guide Figure 24 Dashboard 1 Power flow tab – shows an interactive and graphical view of the power plant with its different connected devices. Battery summary tab – shows a historical line graph of four battery metrics such as 2 current, volts, temperature, and state-of-charge (SOC). It shows one battery at a time. 3 Battery comparison tab – shows a historical and comparative line graph of the four battery metrics against all the different batteries.
Troubleshooting Conext Gateway Conext Gateway Owner's Guide 5 Troubleshooting What's in This Chapter? Events 53
Conext Gateway Conext Gateway Owner's Guide Troubleshooting Events The events detected and monitored by Conext Gateway vary in type. The types of events are categorized into warnings and detected faults. Warnings are displayed as orange icons with an exclamation point. Detected faults are displayed as red icons with an exclamation point. When devices detect an event that usually resolves by itself, it is still reported to Conext Gateway and logged.
Troubleshooting Conext Gateway Conext Gateway Owner's Guide Figure 25 Active events Figure 26 Historical events 975-0806-01-01 54
Conext Gateway Conext Gateway Owner's Guide Troubleshooting To view Events: 1. In the main menu bar, click Events. The Active events are displayed first in the main display board. 2. Click Historical to view events that have been logged and/or resolved. 3. To download a copy of the events, click the CSV icon on the lower right hand corner of the main display board.
Specifications Conext Gateway Conext Gateway Owner's Guide 6 Specifications What's in This Chapter? Electrical Specifications 57 Physical Specifications 57 Features 58 Regulatory 58 FCC Regulatory Compliance 58 ISED Regulatory Compliance 59 Simplified EU Declaration of Conformity 60 Schneider Electric Products that Work with the Conext Gateway 60 Dimensions 61
Conext Gateway Conext Gateway Owner's Guide Specifications Electrical Specifications NOTE: Specifications subject to change without prior notice. NOTICE EQUIPMENT DAMAGE Do not power the unit without first installing the supplied antennas. Failure to follow these instructions can result in equipment damage. Power Consumption 2 W average / 10 W peak AC/DC adapter (supplied) Input: 100-240 V AC, 50-60 Hz, 0.48 A, Output: 12 V DC, 1.6 A, 5.5 mm outer, 2.1 mm centerpositive jack.
Specifications Conext Gateway Conext Gateway Owner's Guide Features NOTE: Specifications subject to change without prior notice.
Conext Gateway Conext Gateway Owner's Guide n Specifications Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. n Consult the dealer or an experienced radio/TV technician for help. Note: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Specifications Conext Gateway Conext Gateway Owner's Guide This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Cet équipement est conforme aux limites d'exposition aux radiations IC CNR-102 établies pour un environnement non contrôlé.
Conext Gateway Conext Gateway Owner's Guide Specifications Dimensions NOTE: Specifications subject to change without prior notice.
Using Chrome to Install the Conext GatewaySecurity Certificate A Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate What's in This Chapter? Installing the Conext Gateway Security Certificate 63
Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate Installing the Conext Gateway Security Certificate These instructions explain how to download the web security certificate from the Conext Gateway and install it on your PC using Chrome on Windows 10. To export the security certificate: 1. Open the Chrome developer tools using one of the following methods: a. Press F12. b.
Using Chrome to Install the Conext GatewaySecurity Certificate Conext Gateway Conext Gateway Owner's Guide 4. Click the Certification Path tab. Figure 28 Certificate path tab 5. Click View Certificate.
Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate 6. Confirm that the hex string following the underscore in the Issued By: statement matches the MAC Address of your Conext Gateway.
Using Chrome to Install the Conext GatewaySecurity Certificate Conext Gateway Conext Gateway Owner's Guide 7. Click the Details tab.
Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate 8. Click Copy to File...to open the Certificate Export Wizard and then click Next.
Using Chrome to Install the Conext GatewaySecurity Certificate Conext Gateway Conext Gateway Owner's Guide 9. Click the radio button beside DER encoded binary and then click Next.
Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate 10. Click Finish to save it to your file system (remember where it has saved).
Using Chrome to Install the Conext GatewaySecurity Certificate Conext Gateway Conext Gateway Owner's Guide To import the security certificate: 1. Using the windows file browser, go to the location where you saved the certificate file, and double-click the certificate file. 2. Click Install Certificate and then click Next.
Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate 3. Click the radio button beside Place all certificates in the following store and then click Browse.
Using Chrome to Install the Conext GatewaySecurity Certificate Conext Gateway Conext Gateway Owner's Guide 4. Click Trusted Root Certificate Authorities and then click OK.
Conext Gateway Conext Gateway Owner's Guide Using Chrome to Install the Conext GatewaySecurity Certificate The Certificate Import Wizard should look like this: Figure 37 Import settings confirmation 5. Click Next and then click Finish. 6. Click Yes to the security warning, and then click OK when the Certificate Import Wizard confirms the import was successful. 7. Restart your browser and confirm the word Secure is now beside the Conext Gateway web user interface address.
Schneider Electric As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication. For other country details please contact your local Schneider Electric Sales Representative or visit the Schneider Electric Solar Business website at: http://solar.schneider-electric.com/ © 2019 Schneider Electric. All Rights Reserved.