Install Instructions

Support and Warranty
www.schlage.com/support
(877) 671-7011
+1 512-712-1316
ULC-S319 compliance is no longer valid when any add-on, expansion, memory, or other module
manufactured or supplied by the manufacturer or manufacturer's representative is used. ULC-S319 Listed
PSU must be used for Canadian installations.
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modications to this equipment not expressly approved by Schlage could void the user’s
authority to operate the equipment.
Industry Canada Statement:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device. This Class A digital
apparatus complies with Canadian ICES-003.
RS485 connection shall not be used in S319 applications until a compatible S319 panel is identied with
RS485 communications.
*xxxxxxxx*
xxxxxxxx
OSDP Secure is recommended panel communication standard.
1
Locate and/or install single gang box.
2
Wire the cable to the control module.
A power limited, class 2 UL 294 approved power supply must be used.
Voltage rating: 5V to 28V
Total length
to power supply or
to panel
To power supply
(power & ground wires)
To panel
(all other wires)
Power supply voltage
12 V 24 V
20 ft (6.1 m) 22 22 22
50 ft (15.2 m) 22 22 22
100 ft (30.5 m) 22 22 22
200 ft (61 m) 22 22 22
300 ft (91.5 m) 20 22 22
400 ft (121.9 m) 18 22 22
500 ft (152.4 m) 18 20 22
600 ft (182.9 m) 18 20 22
700 ft (213.4 m) 18 20 22
800 ft (243.8 m) 16 18 22
900 ft (274.32 m) 16 18 22
1000 ft (305.8 m) - 18 22
Current @ 12V and 25C
Model Avg. mA Max. mA
MTB15 165 195
MTKB15 165 225
Cable Connections
Black Ground
Blue Unused
Brown Red LED Control
Gray* Tamper Out
Consult manufacturer's
instructions for
installation.
5
Plug cable into case.
6
Install case.
In case of alternative mounting screws, only a #6
diameter Pan Head Screw should be used.
7
Snap cover into place and install cover screw.
TEST/SET-UP
a
Power the reader.
The LED will light followed by a beeper tone. This indicates that the
reader is ready.
If LED and beeper do not respond, check cable connections.
b
Present a proper card or token programmed to operate the
reader.
LED Indicators
Green
Card was read and
accepted
Red Card was read but not
accepted (does not indicate
faulty installation)
Do not
over-tighten!
Tamper
Resistant
6-32
x Z\v"
Pin-in-Torx button
head, Use if
desired.
Regular
6-32 x
Z\v"
Cable Connections
Green Wiegand Data 0 / Data
Orange Green LED Control
Pink RS485-A/Y
Red Power In
Shield Shield Ground
Tan RS485-B/Z
White Wiegand Data 1 / Clock
Yellow Beeper Control
3
Route cable through box.
4
Install baseplate.
MTB15
Mobile Enabled Multi-
Technology Reader
MTKB15
Mobile Enabled Multi-
Technology Reader with
keypad
SINGLE GANG READER
INSTALLATION INSTRUCTIONS
MODELS MTB15, MTKB15
Tools
Phillips Screwdriver
6-32 Tap
1" (25 mm), Z\," (3 mm) Drill Bits
T10 Security Torx™ Bit (Optional)
For Indoor/Outdoor Use
The max run for a 5V supply is 50 ft (15 m) with 18 AWG.
* Tamper Outputs are to be connected to a UL Burglary System.

Summary of content (3 pages)