P516-271 CO-200 OFFLINE LOCK USER GUIDE INSTRUCTIONS FOR CORE SERIES OFFLINE LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support.
CO-200 Offline Lock User Guide CONTENTS Overview........................................................................................................................................ 3 Getting Started .............................................................................................................................. 4 Handheld Device (HHD) ................................................................................................................
CO-200 Offline Lock User Guide OVERVIEW The Schlage CO-200 is an off-line electronic lock in the CO-Series product line. • The lock is configured to operate as Classroom/Storeroom function. Optional Office or Privacy functions are available. • The lock is powered by four (4) AA batteries. See Batteries on page 11 for more information. • Outside lever is normally locked. • Inside lever always allows egress. • The lock maintains an audit trail of events in the normal operating mode.
CO-200 Offline Lock User Guide GETTING STARTED Follow these steps when setting up a new lock. 1. Install the lock. See the installation guide that came with the lock, or visit www.schlage.com/support, for more information. 2. Make sure the batteries are installed properly. See Batteries on page 11 for more information. 3. Before programming, the lock may be used in Construction Access Mode. See Construction Access Mode on page 5 for more information.
CO-200 Offline Lock User Guide CONSTRUCTION ACCESS MODE Construction Access Mode is used to allow access before the lock has been programmed, and for testing purposes. • Enabled by default. • The lock will remain in Construction Access Mode until the mode is cancelled as described below. • No audits are captured while lock is in Construction Access Mode. Create the Master Construction Credential - Locks with Card Readers 1. Press and hold the Schlage button while presenting a credential. 2.
CO-200 Offline Lock User Guide MANUAL LOCK PROGRAMMING Right LED Left LED TIPS The Schlage button has two different LEDs, one on the left and one on the right. All locks have a default programming code of 97531 and “* ”. All locks have a default normal use code of 13579 and “#”. ! When adding a card credential, the 3-6 digit code (PIN) entered prior to presenting the card becomes the credential reference number. This number can be used to delete a card without physically having the card.
CO-200 Offline Lock User Guide Manual Programming Commands Commands are confirmed by five alternating green blinks of the Schlage button. The right LED on the Schlage button will blink green to indicate an incorrect entry. To interpret blink patterns, refer to Error Codes on page 9. Function Change [Programming Code] Press/Present OR Programming Card [Programming Code] to stop flashing between each step.
CO-200 Offline Lock User Guide Function Press/Present OR Programming Card [Programming Code] Wait For Confirmation1 Wait for Add Freeze +PIN Credential to stop flashing between each step. New [PIN] New Card add another credential OR [Programming Code] OR to finish Programming Card Wait for Add Pass Through Credential New [PIN] OR (for PIN only) add another credential OR [Programming Code] OR New Card to stop flashing between each step.
CO-200 Offline Lock User Guide USING THE LOCK After credentials have been programmed, present credentials to operate the lock as follows: Credential Type Action Credential Present credential to reader Green blink and access granted + PIN Credential Present credential to reader Within 5 seconds, 2 Press Press PIN 1 Green blink and access granted 1 If the PIN is entered incorrectly, press “ ” to start over.
CO-200 Offline Lock User Guide TESTING If you encounter problems while performing any of the following tests, review the installation guide and correct any problems. Mechanical Testing 1. Rotate the inside lever or depress the push bar to open the door. Operation should be smooth, and the latch should retract. 2. Insert the key into the keyway and rotate the key and the outside lever to open the door. Operation should be smooth, and the latch should retract. Electronic Testing 1.
CO-200 Offline Lock User Guide BATTERIES Installing or Replacing Alkaline Batteries For coin cell battery installation or replacement, refer to instructions at www.schlage.com/support. 1. Remove the battery cover. 2. Remove the Battery Bracket. 3. Install the new batteries. Observe polarity. (Install only new AA alkaline batteries) 4. Install the Battery Bracket. 5. Connect the batteries. 6. Reinstall the battery cover.
LED REFERENCE Most LED indicators are configured with the HHD. See Schlage Utility Software (SUS) User Guide for more information.
Ingersoll Rand Security Technology User Manual Statements Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.