User’s Manual VEGA V-1020 Area Imager Handheld Bar code Scanner
Scantech-ID BV Vanadiumweg 22, 3812PZ Amersfoort The Netherlands. Tel:+31-33-4698400 Fax:+31-33-4650615 E-mail:info@scantech-id.com www.scantech-id.com HEAD QUARTER CHAMPTEK INCORPORATED 5/F, No.2 Alley 2, Shih-Wei Lane, Chung Cheng Rd., Hsin Tien City,Taipei 231, Taiwan Tel:+886-2-2219-2385 Fax:+886-2-2219-2387 E-mail:sales@champtek.com www.champtek.com CHINA CHAMPTEK INCORPORATED #901, No. 39, Wuzhong Rd.
User’s Installation and Configuration Manual Scantech-ID
Copyright © 2009, Scantech-ID BV. This manual is copyrighted, with all rights reserved. Under the copyright laws, this manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic medium or machine readable form without prior written consent of Scantech-ID BV. Limited Warranty Under all circumstances this manual should be read attentively, before installing and/or using the product.
Table of contents Introduction .......................................... 1 Chapter 1 Product Safety ............................... 1 1.1 Safety & Caution ............................... 1 1.2 FCC Warning .................................... 3 1.3 Use of the VEGA ................................ 4 1.4 V-1020 Unpacking ............................... 5 1.5 mounting ....................................... 6 1.6 USB interface .................................. 7 1.7 Configuring ...............................
2.9.2 Error Beep................................. 17 2.9.3 Setup Beep................................. 17 2.10 RS-232 mode parameters .......................18 2.10.1 Baud rate ............................... 18 2.10.2 Data bits ............................... 18 2.10.3 Stop bits ............................... 19 2.10.4 Parity .................................. 19 2.10.5 Handshaking ............................. 19 2.11 Keyboard Wedge Mode Parameter ................20 2.11.1 Terminal Type ..
Introduction VEGA is a cutting-edge gun-type barcode scanner which is designed specifically for retail market. To the brand new series of VEGA, we add on more user-friendly functions with detachable cable that makes it more easily to be operated by the customers. Speaking of the performance, this scanner supports middle to long range operation.
Chapter 1 Product Safety 1.1 SAFETY & CAUTION 1. Please read the following safety statement carefully. 2. Please preserve this user manual for reference sometime. 3. Before cleaning the VEGA, the users must cut off all AC power. Do not use liquid or spray type of detersive to clean the VEGA. Please use dampish cotton cloth to clean the VEGA. 4. The outlet must set nearby the VEGA for connecting power easily. 5. Keep the VEGA dry to avoid short circuit. 6.
13. Don’t storage the VEGA at the temperature lower than -20°C (-4°F) or higher than +70°C (158°F) to avoid any damage.
1.2 FCC WARNING This equipment complies with the requirements in Part 15 of FCC. Any operation must comply with the conditions below: (a) The equipment will not cause any severe interference. (b) The equipment can avoid any interference from environment. Statement: This product is classified as A class product. In environment this product may cause some interference. In this situation the user may do something to avoid interference.
1.3 USE OF THE VEGA The VEGA is very ergonomic and modern designed and very user friendly. It can be connected to your POS or Host system through a RS232 cable, KBW cable, USB cable. To read a bar code, you simply press the red trigger button and aim the beam to the bar code. But you need to position the beam so that it falls across all bars in the 1D barcodes. You will hear one beep and the green LED indicator will lights on after scan successfully.
1.4 V-1020 UNPACKING Unpack the VEGA as follows: 1. Take the VEGA and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered. Standard Shipment Package (a) (b) (c) (d) VEGA Area Imager Handheld Bar code Scanner Communication Cable Power adaptor (optional) User Manual 4. Visually inspect the VEGA and accessories for any evidence of physical damage. 5.
1.5 MOUNTING Once you have unpacked all components, you can start installing the VEGA. Installation at VEGA is divided into different steps: 1. Connect the VEGA to the supplied interface cable (RJ45 side). 2. Connect the VEGA interface cable to the POS system. 3. Connect the Power supply (used RS232 interface) to Power cable jack. 4. Plug the power supply into the AC outlet.
1.6 USB INTERFACE As like all USB devices, before connecting the VEGA with USB interface to your host system, the connect driver must be installed correctly on your host system for VEGA operate successful. Please contact Scantech-ID Technical Support Department if you need the VEGA USB driver or this USB driver can be downloaded from the web site: www.scantech-id.com/support/downloads 1.
1.7.2 Changing Scanner Settings with Utility Tool Scantech-ID has setup this user manual with the most common used programming codes, it could be possible that you need more advanced settings to use the VEGA without any problems into your application. This tool can be used with the following operation systems: Windows98, Windows2000, Windows XP and Windows Vista. This Utility Tool can be delivered on request. Please contact Scantech-ID Technical Support Department.
Chapter 2 Operating Setting 2.1 RETURN TO DEFAULT Scan this programming code to set the scanner /Cradle parameters to factory default: Set the scanner to Factory Default Reset all configuration parameters to their factory default setting of the Scanner and Cradle. After this reset you must select all required parameters that meet applications. 2.2 GET FIRMWARE VERSION Display the firmware version of the scanner, please scan below barcode.
2.3 INTERFACE Selection RS232 SERIAL MODE USB COM PORT MODE 2.4 SCANNING TRIGGERING A reading session begins (lighting and decode processing on) when beam is activated and stops when beam is deactivated. Continuous Scanning When the scanner is turned on a continuous reading session begins (lighting and decode processing on).
Pulse A reading session begins when beam is activated and stays on until a period of inactivity lasting the time specified by the timeout. After the timeout, the scan engine turns off. Flashing Flashing mode allows power up the lighting and decoding are on (no need to activate the trigger line) and after a period of inactivity lasting the time specified by the trigger timeout, the scanner starts flashing, checking for a bar code to be read.
When in Level trigger mode, after a period of inactivity lasting the time specified by the trigger timeout, the scanner switches back to flashing mode. Toggle This mode allows lighting and decoding toggle when the trigger line is activated. First trigger activation = lighting and decoding on, Second trigger activation = lighting and decoding off. Presentation This mode allows power up lighting and decoding are on.
2.6 IMAGER MODE You can set the best reading performance of your VEGA by adjusting certain imager parameters. To choose the best reading performance, depends on the environment, your used application and type of barcodes. Area mode for decode 1D and 2D barcodes. Linear mode for decode 1D Barcodes. Area mode allows you to set the position of the VEGA in any direction regardless of the orientation of the barcode, and perform a good read on 1D and 2D barcodes.
2.7 GOOD READ MODE When active, the scan engine stops the reading session after a successful decoding. - NOTE: this parameter is NOT used with continuous and continuous + flashing modes. Not Active 2.8 BUZZER BEEP TONE 2.8.
2.8.2 Good Read Beeps Two Beeps None 2.8.
2.8.4 Timing Before Transmission After Transmission 2.9 GOOD READ DURATION 2.9.1 Good Read LED Duration <80 msec> 0.
2.9.2 Error Beep Off 2.9.
2.10 RS-232 MODE PARAMETERS 2.10.1 Baud rate 1200 2400 4800 9600 <19200> 38400 2.10.
2.10.3 Stop bits Stop bits 2 2.10.4 Parity Even Odd 2.10.
XON/XOFF Enable 2.11 KEYBOARD WEDGE MODE PARAMETER 2.11.1 Terminal Type IBM PC/XT IBM PS/2 25, 30 2.11.
2.11.3 Upper/Lower Case Upper Case Lower Case 2.11.4 Send Character by ALT Method Enable 2.11.
2.11.
2.11.
Belgium Portuguese Denmark Netherlands Turkey Reserved 1 24
2.
Codablock A ON Codablock F ON CODE 11 ON CODE 39 OFF CODE 93 ON 26
CODE 128 OFF GS1-128 OFF DATAMATRIX OFF DataMatrix – Mirrored labels activation On 27
Dutch Post ON EAN-8 OFF EAN-13 OFF EAN 128 OFF GS1 CC-A/B ON 28
GS1 CC-C ON GS1 DataBar-Omni ON GS1 DataBar-Limited ON GS1 DataBar-Expand ON 29
Infomail ON Interleave 2 of 5 ON Japan Post ON Matrix 2 of 5 ON 30
MaxiCode ON MicroPDF417 ON MSI ON PDF417 OFF Planet ON 31
PLESSEY ON Postnet ON QR Code ON Standard 2 of 5 ON 32
Sweden Post ON Telepen ON TLC 39 ON UPC-A OFF UPC-E OFF 33
Note: This step does not include codes for all support Barcode symbologies. For a complete overview of support symbologies see appendix. If you need programming codes for symbologies which are not available in this chapter, please contact Scantech-ID Technical Support department or use VEGA utility tool.
2.13 MULTI CODE The multicode function is used configure the scanner to read a series of bar codes and then transmit them all at once. Follow these steps to setup the multicode function: 1. Activate the multicode function. 2. Select the number of bar codes to be included the multicode.
Number of bar codes compose: 6 2.
Appendixes A.
B.
C.
D.TECHNICAL SPECIFICATIONS Physical Characteristics Body Weight Material Connector Dimension Approx. 150 gm ABS Plastic RJ45C 10Pins 186.8 mm x 81.6 mm x 63.9 mm Operational Light source Scan rate Optical resolution Scan angle Interface Indicators Visible Red light 650nm + 10nm 200 scans/sec auto adaptive in linear mode. 56 images/sec auto adaptive in 2D mode. 752 Horizontal x 480 Vertical pixels, 256 gray levels.
E.SCAN MAP Typical Reading Distances VEGA Typical Reading Distance: These distances are measured in an office environment (250 lux).
VEGA Typical Reading Distances (centimeters) Symbology Density Code 39 0.125 0.20 0.25 0.50 1.00 0.33 0.19 0.25 0.38 0.16 0.25 0.38 UPC / EAN Data matrix PDF417 mm mm mm mm mm mm mm mm mm mm mm mm Minimum Distance 7.2 cm 3.8 cm 3.4 cm 5.0 cm 8.0 cm 5.0 cm 6.3 cm 4.8 cm * 6.2 cm 4.5 cm 4.0 cm Maximum Distance 13.1 cm 22.5 cm 27.0 cm 44.0 cm 83.0 cm 32.0 cm 17.2 cm 22.0 cm 29.0 cm 15.4 cm 23.0 cm 37.0 cm VEGA Typical Reading Distances (inches) mils Minimum Distance 2.8 Inch Maximum Distance 5.