(FKR3RLQW 6LJQSRVW ,QVWDOODWLRQ *XLGH 9HUVLRQ
First edition (September 2001) Part number 805-03634-001 Rev. B Copyright © 2002 Savi Technology, Inc. All rights reserved. Printed in the United States of America. Information in this manual is subject to change without notice and does not represent a commitment from the vendor. The software and/or databases described in this document are furnished under a license agreement or nondisclosure agreement. The software and/or databases may be used or copied only in accordance with the terms of the agreement.
8 6 5HJXODWRU\ $SSURYDOV 8 6 5HJXODWRU\ $SSURYDOV (FKR3RLQW 6LJQSRVW 63 DQG 63 )HGHUDO &RPPXQLFDWLRQV &RPPLVVLRQ )&& 1RWLFH The Federal Communications Commission has established technical standards regarding radio frequency energy emitted by computer devices. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
,QWHUQDWLRQDO 5HJXODWRU\ $SSURYDOV ,QWHUQDWLRQDO 5HJXODWRU\ $SSURYDOV (FKR3RLQW 6LJQSRVW 63 DQG 63 'HFODUDWLRQ RI &RQIRUPLW\ Hereby, Savi Technology, Inc. 615 Tasman Drive Sunnyvale, California 94086-1707 declares that the EchoPoint Signpost SP-600-101 and SP-600-201 are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. 0889 3URGXFW 6DIHW\ CB Scheme (IEC 60950).
&RQYHQWLRQV LQ WKLV *XLGH &RQYHQWLRQV LQ WKLV *XLGH The following table explains guide conventions and typography usage. *XLGH &RQYHQWLRQV Example Meaning and Use Note: Notes call attention to facts or advice that deserve special attention. Caution notices call attention to the possibility of damaging the product, the system, or your work (for example, potential loss of data). Warning notices call attention to the possibility of injury to people.
DEOH RI &RQWHQWV U.S. Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . iii EchoPoint Signpost SP-600-101 and SP-600-201 . . . . . . iii International Regulatory Approvals . . . . . . . . . . . . . . . . . . . . iv EchoPoint Signpost SP-600-101 and SP-600-201 . . . . . . iv Conventions in this Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Chapter 1: Introduction EchoPoint Signpost Description . . . . . . . . . . . . . . . . . . . . . .
,QWURGXFWLRQ 1 This guide describes how to install the EchoPoint Signpost, including hardware installation and using the software to configure the Signpost. Signposts are short-range transmitters that provide their identity information to the EchoPoint Series 600 tags (Tags) that are within range. A Tag uses this information to relay positional information about itself to an EchoPoint Reader SR-600-101 (Reader).
(FKR3RLQW 6LJQSRVW 'HVFULSWLRQ (FKR3RLQW 6LJQSRVW 'HVFULSWLRQ The EchoPoint Signpost is available in two configurations. Model SP-600-201 has an external antenna, and SP-600-101 has an internal antenna. Both configurations operate at a nominal frequency of 132 kHz. 0RGHO 63 6LJQSRVW 'HVFULSWLRQ The EchoPoint Signpost SP-600-201 is a two-part assembly consisting of a controller attached to an antenna.
(FKR3RLQW 6LJQSRVW 'HVFULSWLRQ 0RGHO 63 6LJQSRVW 'HVFULSWLRQ The EchoPoint Signpost SP-600-101 is a one-part assembly consisting of a controller with a built-in antenna. Like the Model SP-600-201 Signpost, the Model SP-600-101 Signpost is powered by AC or DC, with the AC having a range of 85 to 264 Volts at 47 to 440 Hz, while the DC range is 11 to 30 Volts.
6SHFLILFDWLRQV 6SHFLILFDWLRQV EchoPoint Signpost specifications are documented in Table 1-1. 7DEOH 6LJQSRVW 6SHFLILFDWLRQV Signpost Type Specification Model SP-600-201 Signpost Power AC or DC AC range 85 to 264 Volts at 47 to 440 Hz, 800/400 ma DC range 11 to 30 Volts, 800 ma Weight 14.7 pounds (with controller mounted) 2 pounds (controller) Dimensions 19.5" x 109.25" x 4.8" 19.5" x 109.25" x 2.5" (without controller) 7.5" x 7.
*HWWLQJ $VVLVWDQFH *HWWLQJ $VVLVWDQFH If you have trouble with the product, after you have checked your connections and the EchoPoint Signpost Installation Guide, contact Savi Technical Support. 7HFKQLFDO 6XSSRUW To contact Savi Technical Support: • Telephone 1-888-994-SAVI (7284) between 8:00 a.m. and 5:00 p.m., Pacific Time • Or send e-mail to help@savi.
+DUGZDUH ,QVWDOODWLRQ 2 This chapter covers installing the EchoPoint Signpost Model SP-600-201 and Model SP-600-101 hardware, including the required tools and materials, site preparation, and making the physical installation and power connections.
5HTXLUHG 0DWHULDOV DQG (TXLSPHQW 5HTXLUHG 0DWHULDOV DQG (TXLSPHQW The required materials, equipment, and tools for installing both EchoPoint Signpost models are listed in Table 2-1.
3UHSDULQJ WKH 6LWH 3UHSDULQJ WKH 6LWH Mounting a Signpost requires no specific site preparation. The criteria for placement and the preparation include the considerations listed in Table 2-2. 7DEOH 6LWH 3UHSDUDWLRQ &RQVLGHUDWLRQV Consideration Addressed by ... Safety Avoid selecting a Signpost installation location where harm to the equipment or personnel is possible. Power Select an installation location where power is accessible. Space Allow sufficient space to install the Signpost.
3UHSDULQJ WKH 6LWH 7DEOH 6LWH 3UHSDUDWLRQ &RQVLGHUDWLRQV Consideration Addressed by ... Locations not permitted Signposts must not be used in areas not permitted by government regulation. Savi can help with determining applicable countries and locations. Overhead support for Determine the layout and capacity of the overhead structure that will be supporting the Signpost. Model SP-600-201 Model SP-600-201 Signpost assemblies, including the Signposts Signpost and antenna (weight 14.7 pounds).
0RXQWLQJ WKH 6LJQSRVWV 0RXQWLQJ WKH 6LJQSRVWV This section covers the installation procedures for Model SP-600-201 and Model SP-600-101 Signposts. 0RXQWLQJ WKH 0RGHO 63 6LJQSRVW Model SP-600-201 Signposts can be hung adjacent to a portal or other choke point using the supplied installation hanger kit. The actual installation is dependent on the individual circumstances and how power is to be supplied, but a number of tasks need to be performed in all cases.
0RXQWLQJ WKH 6LJQSRVWV » To mount a Model SP-600-201 Signpost 1. Attach a removable 1/8 inch link to each of the four mounting brackets at the four corners of the unit. )LJXUH 5HPRYDEOH /LQN 5HPRYDEOH OLQN 2. Using two lengths of plastic chain, attach each at both ends to the four removable links, as shown in Figure 2-1 and Figure 2-2.
0RXQWLQJ WKH 6LJQSRVWV )LJXUH $WWDFKLQJ &KDLQ 5HPRYDEOH OLQN 3ODVWLF FKDLQ 3. Attach another removable link to the center of the chain, as shown in Figure 2-2 above. 4. Attach the top removable link to an appropriate rope, cable, or chain and fasten to a 3/8 inch eye screw or eye bolt (minimum 1-1/2 inch penetration into solid material, or through bolt). 5. Secure the power cord to the chain and route as required.
0RXQWLQJ WKH 6LJQSRVWV 0RXQWLQJ WKH 0RGHO 63 6LJQSRVW Model SP-600-101 Signposts are supplied with mounting feet. The actual installation is dependent on the individual circumstances and how power is to be supplied, but a number of tasks need to be performed in all cases. » To mount a Model SP-600-101 Signpost 1. Attach the mounting feet. Figure 2-3 below shows the mounting feet with the self-tapping screws that attach them to the Signpost.
0RXQWLQJ WKH 6LJQSRVWV )LJXUH 0RXQWLQJ )RRW $WWDFKHG WR 0RGHO 63 6LJQSRVW 2. Attach the mounting feet to the mounting surface. DO NOT attach the mounting feet to drywall only, unless the drywall is backed by solid structural material, in which case screws need to penetrate a minimum of 3/4 inch into solid material.
0RXQWLQJ WKH 6LJQSRVWV &DEOLQJ WKH 0RGHO 63 6LJQSRVW The only cabling required for a basic installation is operating power. This needs to be done in accordance with applicable safety regulations. All cables should be routed and protected in a manner which precludes damage to them or harm to personnel; for example, unsecured extension cords left across access-ways or where assets or asset moving equipment can damage them.
0RXQWLQJ WKH 6LJQSRVWV » To cable a Model SP-600-201 Signpost: No cabling is required for the Model SP-600-201 Signpost and its antenna. This connection has already been made, as shown in Figure 2-5. )LJXUH 0RGHO 63 6LJQSRVW $QWHQQD &RQQHFWLRQ $QWHQQD FRQQHFWLRQ 1. Run the appropriate power cable to the Signpost. 2. Connect the power cable to the Signpost Power connector, as shown in Figure 2-6.
0RXQWLQJ WKH 6LJQSRVWV )LJXUH 0RGHO 63 6LJQSRVW 3RZHU &RQQHFWLRQ 3RZHU FRQQHFWLRQ 3. Continue with configuration using the Signpost configuration software. See “Configuring Signpost Operation Settings” on page 3-3.
0RXQWLQJ WKH 6LJQSRVWV &DEOLQJ WKH 0RGHO 63 6LJQSRVW The connectors and LED shown in Table 2-4 are available on a Model SP-600-101 Signpost. 7DEOH 0RGHO 63 6LJQSRVW &RQQHFWRUV DQG /('V Connectors and LEDs Description Power The input power is connected here. RS-232 Used to connect to a computer for setup and diagnostics by installers and technicians. Sync In Used to synchronize 2 to 4 Model SP-600-101 Signposts to cover an area larger than is possible with a single Signpost.
6LJQSRVW 6\QFKURQL]DWLRQ 6LJQSRVW 6\QFKURQL]DWLRQ For a transmit group to work, the Sync cable must be connected between the Signposts. These optional cables are available from Savi Technology in variable lengths. » To cable a Signpost for synchronization: 1. Connect the female end of the cable to the Sync In connector of the Signpost. 2. Connect the male end of the cable to the Sync Out connector of another Signpost in the synchronized group. 3. Create group number assignments.
6LJQSRVW &RQILJXUDWLRQ 3 Signpost operation requires that you configure some Signpost parameters using the Signpost configuration software application. This chapter provides instructions for connecting Signposts to the computer and configuring Signposts using the software. Note: It is assumed that the Signpost configuration software application is installed on the computer being used to configure a Signpost.
&RQQHFWLQJ 6LJQSRVWV WR D &RPSXWHU &RQQHFWLQJ 6LJQSRVWV WR D &RPSXWHU Signposts are connected to a computer with an RS-232 serial connection. Both Model SP-600-201 and Model SP-600-101 Signposts have an RS-232 port which is temporarily used for configuration with Signpost configuration software when the Signpost is installed. Figure 3-1 shows the serial ports for the Model SP-600-201 Signpost. The Model SP-600-101 RS-232 is similar.
&RQILJXULQJ 6LJQSRVW 2SHUDWLRQ 6HWWLQJV &RQILJXULQJ 6LJQSRVW 2SHUDWLRQ 6HWWLQJV Either before or after the Signpost is installed, the installer should set and verify the following settings for operation. This activity is performed using a computer having the Signpost configuration software application installed. Before verifying these settings, you need to connect the computer to the Signpost, which is documented in “Connecting Signposts to a Computer” on page 3-2.
&RQILJXULQJ 6LJQSRVW 2SHUDWLRQ 6HWWLQJV 4. Power level Generally, the maximum setting of 1023 is used, but this number can be reduced to reduce power; the higher the number, the higher the power. However, range does not increase linearly with an increase in the power level, and may require a number of trial settings to achieve the appropriate power level. 5. Tx Mode The Tx mode should be set to normal mode. 6. Status The version should be verified so that all Signposts are compatible with the system.