TLS-01 TELEMETRY LOGGER SYSTEM No.
TLS-01 TELEMETRY LOGGER SYSTEM TabLE Of cOnTEnTS Introduction................................................................................................................................. Page 3 Product Compatibility ............................................................................................................ Page 3 General 2.4GHz Frequency Band Precautions ......................................................... Page 4 TLS-01 Telemetry Logger Precautions ................................
TLS-01 TELEMETRY LOGGER SYSTEM inTROducTiOn Thank you for purchasing the Airtronics TLS-01 Telemetry Logger. The TLS-01 Telemetry Logger is a hand-held device, that when used with an Airtronics or Sanwa telemetry-equipped transmitter and receiver, you can monitor and record your model’s telemetry data, including RPM or speed, receiver voltage and two different temperature readings, in addition to steering and throttle output data, all in real-time at the track.
TLS-01 TELEMETRY LOGGER SYSTEM GEnERaL 2.4GHz fREquEncY band pREcauTiOnS l l l l l The 2.4GHz frequency band may be used by other devices, and other devices in the immediate area may cause interference on the same frequency band. Always before use, conduct a bench test to ensure that system is operating properly. Also, conduct a range check at the area of operation to ensure that the radio system has complete control of your model at the farthest reaches of the operational area.
TLS-01 TELEMETRY LOGGER SYSTEM TLS-01 TELEMETRY LOGGER fEaTuRES l Monitor and record your model’s telemetry data, including RPM or speed, receiver voltage and two different temperature readings†, in addition to steering and throttle output data, all in real-time. l Built-in lap timer with interval timer and goal time alarm. l Display and monitor telemetry data in both graphical and numerical formats. l Record telemetry data for later review.
TLS-01 TELEMETRY LOGGER SYSTEM fEaTuRES diaGRaMS Use the diagrams in this section to familiarize yourself with the basic features of your TLS-01 Telemetry Logger. Descriptions of these features can be found in the Features Descriptions section on pages 7 and 8.
TLS-01 TELEMETRY LOGGER SYSTEM fEaTuRES dEScRipTiOnS Antenna - Receives the signal from the transmitter. Never touch the antenna during use. Doing so may degrade reception. During use, adjust the antenna so that it’s orientated in a vertical position. BAck/cAncel key - Press to cancel a programming entry or return to the previous menu. When anywhere in the MAIN menu or its sub-menus, press and HOLD to return to the last viewed telemetry data monitoring screen.
TLS-01 TELEMETRY LOGGER SYSTEM fEaTuRES dEScRipTiOnS Rec/stoP key - Press to start and stop the Telemetry Data Recording function. In addition, activates and deactivates the Lap Timer function at the same time. scAle key - Press to change the resolution between telemetry data points. Decrease the Scale value to see more detail or increase the Scale value to see less detail. wrist strap Anchor - Used to attach a wrist strap (not included).
TLS-01 TELEMETRY LOGGER SYSTEM LOw vOLTaGE aLaRM The TLS-01 Telemetry Logger features a low voltage alarm that will sound to remind you to replace the batteries. The low voltage alarm will sound, a warning will be displayed, and LED 2 will flash when the battery voltage reaches 4.5v. After approximately 10 seconds, the alarm will cease or it can be cancelled prior to that by pressing the ENTER key or the BACK/CANCEL key. When the battery voltage reaches 4.
TLS-01 TELEMETRY LOGGER SYSTEM bindinG THE TLS-01 TELEMETRY LOGGER The Bind function is used to pair the TLS-01 Telemetry Logger to your transmitter. It is necessary to bind the TLS-01 Telemetry Logger and transmitter so that telemetry data can be received by the TLS-01 Telemetry Logger. Once the binding procedure is complete, the bind code is remembered even when the TLS-01 Telemetry Logger and transmitter are turned OFF.
TLS-01 TELEMETRY LOGGER SYSTEM TELEMETRY daTa MOniTORinG ScREEnS OvERviEw Use the diagrams in this section to familiarize yourself with the layout of the telemetry data monitoring screens.
TLS-01 TELEMETRY LOGGER SYSTEM TELEMETRY daTa MOniTORinG ScREEnS OvERviEw lap time indicator - Indicates the position along the telemetry monitor screen that a lap time has been counted. numerical telemetry Data - Displays the current telemetry data in numerical format. scale - Indicates the current resolution in seconds between telemetry data points. Decrease the Scale value to see more detail or increase the Scale value to see less detail.
TLS-01 TELEMETRY LOGGER SYSTEM uSinG THE TLS-01 TELEMETRY LOGGER using the disPLaY KeY 1) Press the DISPLAy key to cycle through the eight different telemetry data monitoring screens, including the screen. The DISPLAy key will not function from any of the programming menus. If necessary, press and HOLD the BACK/CANCEL key to return to the last telemetry monitoring screen displayed. From within any telemetry data monitoring screen, press the ENTER key to open the MAIN menu.
TLS-01 TELEMETRY LOGGER SYSTEM uSinG THE TLS-01 TELEMETRY LOGGER using the teLemetrY data reCording FunCtion 1) To record telemetry data, press the REC/STOP key. An audible double-tone will sound, LED 1 will flash and the lap time will flash. 2) To stop recording telemetry data, press the REC/STOP key a second time. An audible double-tone will sound, LED 1 will stop flashing and the lap time will stop flashing.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu oVeRView To access the SET UP menu, turn the TLS-01 Telemetry Logger ON. Press the ENTER key to open the MAIN menu. The SET UP menu will be highlighted. Press the ENTER key to open the SET UP menu. The following SET UP sub-menus are available by scrolling UP or DOWN and pressing the ENTER key: MenU MenU DescRiPtion PAge 01.REC Change Telemetry Data Recording Options PG. 15 02.RPM Change Telemetry Data RPM Options PG. 18 03.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the reCord start VaLue, Continued.... 2) Press the ENTER key. The REC menu will be displayed and REC START SW will be highlighted. 3) Press the ENTER key, then scroll UP or DOWN to choose the desired Record Start value. This value determines how the Telemetry Data Recording function is started. sw - The Telemetry Data Recording function is started by pressing the REC/STOP key.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the reCord stoP VaLue, Continued.... teMP1 - The Telemetry Data Recording function will stop when the Temperature 1 sensor reaches the Maximum Temperature value selected in the SET UP TEMP1 menu. For more information, see the Changing the Max Temp Value section on page 24. teMP2 - The Telemetry Data Recording function will stop when the Temperature 2 sensor reaches the Maximum Temperature value selected in the SET UP TEMP2 menu.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the reCord interVaL VaLue, Continued.... 1) From within the REC menu, scroll UP or DOWN to highlight REC INTERVAL 0.1sec. 2) Press the ENTER key, then scroll UP or DOWN to choose the desired Record Interval value. Choosing a lower Record Interval value results in narrower, higher resolution data, but for a shorter period of time. Choosing a higher Record Interval value results in broader, lower resolution data, but for a longer period of time.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the max rPm/sPeed VaLue The Max RPM/Speed value determines the maximum RPM or Speed that will be displayed on the RPM telemetry screen. 1) From within the RPM menu, scroll UP or DOWN to highlight MAX RPM 30000, MAX SPEED 54KM/H or MAX SPEED 34MPH. 2) Press the ENTER key, then scroll UP or DOWN to choose the desired Maximum RPM or Maximum Speed value. MAX RPM setting range is 500 to 127500. The default setting is 30000.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu CaLiBrating the rPm sensor - ratio VaLue, Continued.... The Ratio value is the gear ratio between the two gears that the RPM sensor is mounted to. For example, if the RPM sensor is mounted to your spur gear, the Ratio value will be the gear ratio of your spur gear and pinion gear. To calculate the gear ratio, divide the number of teeth in the spur gear by the number of teeth in the pinion gear.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu CaLiBrating the rPm sensor - 10Count distanCe VaLue, Continued.... 1) With your transmitter and receiver turned ON, place your model on the ground. 2) Measuring from where you set your model on the ground, push your model and measure the distance covered to complete 10 full revolutions of the RPM sensor (the bind LED on your receiver will flash 10 times, indicating 10 full revolutions).
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the max VoLt VaLue, Continued.... 2) Press the ENTER key. The VOLT menu will be displayed and MAX VOLT 9.0V will be highlighted. 3) Press the ENTER key, then scroll UP or DOWN to choose the desired Maximum Voltage value. This value determines the maximum voltage that will be displayed on the VOLT telemetry screen. MAX VOLT setting range is 3.0V to 9.0V. The default setting is 9.0V.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 04.teMP1 and 05.teMP2 The Temp1 and Temp2 functions allow you to change the way temperature telemetry data is displayed on the TEMP1 and TEMP2 telemetry screens. you're able to change the unit of temperature (Fahrenheit and Celcius), the maximum and minimum temperatures displayed, and the Alert Temperature Alarm, which will sound to warn you that the component being monitored has reached the programmed temperature value.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the max temP VaLue The Maximum Temperature value determines the maximum temperature that will be displayed on the TEMP1 or TEMP2 telemetry screens. We suggest that the Maximum Temperature value be set higher than the Alert Temperature value programmed in the Changing the Alert Temp Value section below. 1) From within the TEMP1 or TEMP2 menu, scroll UP or DOWN to highlight MAX TEMP 248ºF or MAX TEMP 120ºC.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the aLert temP VaLue, Continued.... 2) Press the ENTER key, then scroll UP or DOWN to choose the desired Alert Temperature value. ALERT TEMP setting range is 68ºF to 302ºF (0ºC to 150ºC). The default setting is 212ºF (100ºC). We don't suggest setting the Alert Temperature value higher than the Maximum Temperature value. The Alert Temperature value cannot be set lower than the Minimum Temperature value.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 06.lAP The Lap function allows you the option of programming an interval timer and alarm that can be used to enhance the lap timer. In addition, the method used to start the lap timer and count lap times can be changed. For example, you can start the lap timer and count lap times using the LAP switch or you can start the lap timer and count lap times from your transmitter remotely.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu setting the interVaL timer (target time), Continued.... 5) To set the Interval Timer 1/100th Seconds value, press the ENTER key, then scroll DOWN to highlight --. Press the ENTER key a second time, then scroll UP or DOWN to set the desired Interval Timer 1/100th Seconds value. LAP INT setting range is -- : -- . -- to 99 : 59 : 99. The default setting is -- : -- . -- (OFF).
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the start/stoP VaLue, Continued.... 2) Press the ENTER key, then scroll UP or DOWN to choose the desired Start/Stop value. sw - The lap timer is started and lap times are counted by pressing the LAP key. AUX1P1/P2 or AUX2P1/P2 - The lap timer is started and lap times are counted remotely via your transmitter using one of the programmable Auxiliary functions. For more information, see the AUX Function section on page 33.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Changing the start/stoP auto VaLues Continued.... 3) Press the ENTER key, then scroll DOWN to highlight [TIME] 0.8sec. 4) Press the ENTER key, then scroll UP or DOWN to choose the desired Time value. This value determines how long the throttle must be held in the Throttle Percentage position before the lap timer starts or lap times are counted. LAP TIME setting range is 0.1sec to 5.0sec. The default setting is 0.8sec.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 07.st Point The ST Point function allows you to calibrate the TLS-01 Telemetry Logger so that both graphical and numerical steering output data is displayed correctly on the telemetry data monitoring screens. If you don't use the ST Point function to calibrate the TLS-01 Telemetry Logger, steering output data may not match your transmitter's steering wheel movement, resulting in erroneous readings.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 08.th Point The TH Point function allows you to calibrate the TLS-01 Telemetry Logger so that both graphical and numerical throttle output data is displayed correctly on the telemetry data monitoring screens. If you don't use the TH Point function to calibrate the TLS-01 Telemetry Logger, throttle output data may not match your transmitter's throttle trigger movement, resulting in erroneous readings.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 09.eXteRnAl st/th The External ST/TH function allows you to change the way the TLS-01 Telemetry Logger connects to different types of transmitters. When the External option is selected, the TLS-01 Telemetry Logger can connect to transmitters operating on FH2, DS2, FM or AM frequency bands* using the two External Input Connectors (included). This allows you to use these legacy transmitters and still be able to view and record steering and throttle output data.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 10.AUX fUnction The AUX Function allows you to use your transmitter's auxiliary channel(s) to control specific TLS-01 Telemetry Logger functions remotely. This allows you to control these functions yourself, without the need for another person to control them directly from the TLS-01 Telemetry Logger.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu Programming the auxiLiarY 1 FunCtion, Continued.... 4) Rotate the auxiliary 1 dial all the way back (or in another desired position), then scroll DOWN to highlight AUX1 [OFF] POS2 0 and press the ENTER key. 5) Move auxiliary 1 dial forward and backward to test that it's working as desired.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu 11.log nAMe eDit The Log Name Edit function allows you to change the default name of telemetry data logs. For example, if you're practicing on a given day or with a specific model, you can first change the Log-Data name to the day and date (e.g. WED 10-12) or your model's name and all telemetry data logs will feature this name. This makes it easier to keep track of multiple telemetry data logs without the need to rename them after they're recorded.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu editing the Log name, Continued.... 6) Scroll UP or DOWN to select the next desired character, then repeat step 5 to enter the rest of the characters. Up to ten characters can be entered. If necessary, press the BACK/CANCEL key to gain focus of the underscore. deLeting a CharaCter 1) Scroll UP or DOWN to move the underscore under the character in the log name you want to delete.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu modeL seLeCt - seLeCting a modeL, Continued.... 2) Press the ENTER key. MODEL SELECT will be highlighted. 3) Press the ENTER key to open the MODEL SELECT menu. The currently selected model will be displayed and also highlighted in the model select list. 4) Scroll UP or DOWN to highlight the model you would like to load. 5) Press the ENTER key. Select This Model? will be displayed.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu modeL name - editing the modeL name, Continued.... 1) From within the SET UP MODEL menu, scroll UP or DOWN to highlight the MODEL NAME menu. 2) Press the ENTER key. The current model name will be displayed, [BACK] will be highlighted and the underscore will be flashing under the first editable character in the model name. 3) Scroll UP or DOWN to move the underscore to the character you would like change.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu modeL name - deLeting the modeL name 1) Scroll DOWN to move the underscore under the last character in the model name. 2) Press the ENTER key. Scroll UP or DOWN to highlight [BACK], then continuously press the ENTER key to delete each character in the model name. modeL CoPY - CoPYing Programming data The Model Copy function allows you to copy the bind code, Set Up menu programming data and model name from one model to another model.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu modeL CoPY - CoPYing Programming data, Continued.... 4) Press the ENTER key. Copy To This Model? will be displayed. Scroll DOWN to highlight yES, then press the ENTER key to copy programming data TO the selected model. 5) After pressing the ENTER key, Executed will flash, indicating the programming data is being copied. After copying, the Model Copy menu will reopen.
TLS-01 TELEMETRY LOGGER SYSTEM SET up MEnu modeL CLear - resetting deFauLt VaLues, Continued.... 3) After pressing the ENTER key, Executed will flash, indicating the programming data is being cleared. After the process is complete, the Model Clear menu will reopen. If you don't want to clear the selected model's programming data, highlight NO, then press the ENTER key or press the BACK/CANCEL key to return to the previous screen.
TLS-01 TELEMETRY LOGGER SYSTEM LOG daTa MEnu oVeRView To access the LOG DATA menu, turn the TLS-01 Telemetry Logger ON. Press the ENTER key to open the MAIN menu, then scroll DOWN to highlight the LOG DATA menu. Press the ENTER key to open the LOG DATA menu. The following LOG DATA sub-menus are available by scrolling UP or DOWN and pressing the ENTER key: MenU MenU DescRiPtion PAge 01.LOG LOAD Load Telemetry Data Logs PG. 42 02.LOG REVIEW Review Telemetry Data Logs PG. 43 03.
TLS-01 TELEMETRY LOGGER SYSTEM LOG daTa MEnu Loading teLemetrY data Logs, Continued.... 3) Scroll UP or DOWN to highlight the desired telemetry data log you would like to load. 4) Press the ENTER key. Select This Log? will be displayed. Scroll DOWN to highlight yES, then press the ENTER key to load the selected telemetry data log. If you don't want to load the selected telemetry data log, highlight NO, then press the ENTER key or press the BACK/CANCEL key to return to the previous screen.
TLS-01 TELEMETRY LOGGER SYSTEM LOG daTa MEnu reViewing teLemetrY data Logs, Continued.... 2) Press the ENTER key. The telemetry data review screen will be displayed.
TLS-01 TELEMETRY LOGGER SYSTEM LOG daTa MEnu naVigating the teLemetrY data reView sCreens, Continued.... UP/Down key - Scroll UP and DOWN to move the current position indicator (indicated by a solid vertical line), to the desired location to view the current time position and telemetry data at that exact point. The current time position and current telemetry data are displayed along the bottom of the telemetry data screen.
TLS-01 TELEMETRY LOGGER SYSTEM LOG daTa MEnu 03.log nAMe The Log Name function allows you to rename telemetry data logs to make it easier for you to keep track of them. The log name can consist of up to 10 letters, numbers or symbols. Choose from capital letters, lower case letters, numbers and various symbols. A telemetry data log must be loaded before it can be renamed. For more information, see the Loading Telemetry Data Logs section on page 42.
TLS-01 TELEMETRY LOGGER SYSTEM LOG daTa MEnu naming teLemetrY data Logs, Continued.... 6) Scroll UP or DOWN to select the next desired character, then repeat step 5 to enter the rest of the characters. Up to ten characters can be entered. If necessary, press the BACK/CANCEL key to gain focus of the underscore. deLeting a CharaCter 1) Scroll UP or DOWN to move the underscore under the character in the log name you want to delete.
TLS-01 TELEMETRY LOGGER SYSTEM SYSTEM MEnu oVeRView To access the System Menu, turn the TLS-01 Telemetry Logger ON. Press the ENTER key to open the MAIN menu, then scroll DOWN to highlight the SySTEM menu. Press the ENTER key to open the System Menu. The following SySTEM sub-menus are available by scrolling UP or DOWN and pressing the ENTER key: MenU MenU DescRiPtion PAge 01.BIND Bind the TLS-01 Telemetry Logger to your Transmitter PG. 48 02.
TLS-01 TELEMETRY LOGGER SYSTEM SYSTEM MEnu Changing the VoLume Increasing the Volume value will increase the volume of the audible key tones and decreasing the Volume value will decrease the volume of the audible key tones. When the Volume value is OFF, audible key tones, including lap timer audio tones, will be muted. 1) From within the SySTEM menu, scroll DOWN to highlight the BUZZER menu. 2) Press the ENTER key. The BUZZER menu will be displayed and VOLUME 4 will be highlighted.
TLS-01 TELEMETRY LOGGER SYSTEM SYSTEM MEnu 03.lcD The LCD function allows you to change the contrast of the LCD screen to make it easier to read in all types of lighting conditions. In general, increasing the contrast will make the LCD screen easier to read in bright sunlight and decreasing the contrast will make the LCD screen easier to read in low light levels. Changing the Contrast 1) From within the SySTEM menu, scroll DOWN to highlight the LCD menu. 2) Press the ENTER key.
TLS-01 TELEMETRY LOGGER SYSTEM SYSTEM MEnu Before proceeding, make sure that the TLS-01 Telemetry Logger is turned ON and connected to your PC, and that the PC-Link Manager software is installed on your PC and running. For more information, refer to the User's Guide included with the PC-Link Manager software. saVing teLemetrY data Logs 1) From within the SySTEM menu, scroll DOWN to highlight the PC-LINK menu. 2) Press the ENTER key.
TLS-01 TELEMETRY LOGGER SYSTEM SYSTEM MEnu saVing teLemetrY data Logs 8) Press the ENTER key. Transfer OK? will be displayed. Scroll DOWN to highlight yES, then press the ENTER key. 9) After the telemetry data log transfer is complete, click the OK button on the PC-Link Manager software. If you don't want to save the selected telemetry data log, highlight NO, then press the ENTER key or press the BACK/CANCEL key to return to the previous screen.
TLS-01 TELEMETRY LOGGER SYSTEM SYSTEM MEnu uPdating the soFtware Version, Continued.... 4) Scroll DOWN to highlight yES, then press the ENTER key to begin the software update process. 5) After the software update process is finished, unplug the TLS-01 Telemetry Logger from your PC, then turn the TLS-01 Telemetry Logger OFF then back ON again. Do NOT turn your PC or the TLS-01 Telemetry Logger OFF during the update process. The update process can take up to 5 minutes or longer to finish.
TLS-01 TELEMETRY LOGGER SYSTEM nOTES 54
TLS-01 TELEMETRY LOGGER SYSTEM nOTES 55
TLS-01 TELEMETRY LOGGER SYSTEM Airtronics is Distributed exclusively in north America by: global hobby Distributors 18480 Bandilier circle fountain Valley, cA 92708 telephone: (714) 963-0329 fax: (714) 964-6236 email: service@airtronics.net http://globalservices.globalhobby.com http://www.airtronics.net 56 Features and Specifications are Subject to Change Without Notice All contents © 2011 Airtronics, Inc. All Rights Reserved. Revision 1 - 10.26.