MACERATORS, GRINDERS, LIFT STATIONS, DRAIN AND CONDENSATE PUMPS A pump company since 1958 providing plumbing solutions for residential and commercial applications
Shaking up water S aniflo offers a range of macerating and grinding pump systems that greatly reduce the size of fecal matter and waste. Larger diameter discharge lines are unnecessary; in fact, all that is needed is a 3/4” diameter discharge line. The flexibility of Saniflo systems makes any sanitar y application you can imagine possible.
INDEX Page 4-5 Page 6 Page 7 OPERATING PRINCIPLE OF SANIFLO SYSTEM SANIFLO’S TOILET SYSTEMS SIZING THE BEST PRODUCT FULL BATHROOM Pages 8-9 Pages 10-11 SANIPLUS SANI 3 SANIPACK SANIBEST PRO Pages 16-17 SANIGRIND PRO Pages 12-13 Pages 14-15 Pages 18-21 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 CASE STUDIES HALF-BATHROOM Pages 22-23 SANI SANICOMPACT Pages 26-27 SANICOMPAC T COMFORT Pages 28-29 SANISTAR Pages 24-25 Pages 30-31 CASE STUDIES DRAIN PUMP
OPERATING PRINCIPLE OF THE SANIFLO SYSTEM AFTER BEFORE BEFORE AFTER Above-floor plumbing technology eliminates the need to break the concrete or floor which means no disruptive or destructive remodeling. Floors, walls, and structural integrity remain intact while the project time is reduced and construction mess is virtually eliminated.
1 WHAT IS A MACERATOR? When the toilet is flushed, the water level rises and the Saniflo grinder motor turns on automatically. SANIPLUS SANIPACK SANI ® ® SANICOMPACT SANICOMPAC T COMFORT SANISTAR SANI ® ® ® To “macerate” is to soften and break in pieces. Our Saniflo macerating systems use a stainless steel rotating blade to liquefy human waste and toilet paper. When mixed with flushing water the waste is pumped into a sanitary sewer as a fine slurry.
SANIFLO’S TOILET SYSTEMS Saniflo’s vitreous china toilets are designed to be durable with a high gloss finish for an easy-to-clean surface. These floor mounted, rear discharge toilets have the desired height to meet comfort and aesthetics to provide a unique style. Saniflo’s high efficiency toilets use 1.28 gallons per flush (4.8 lpf) and are recognized by the EPA’s water-saving WaterSense program.
SIZING THE BEST PRODUCT Saniflo offers several models for different applications and requirements. Choosing the best product that meets your needs is the first step towards completing your project. From residential to commercial applications for either gray or black water, Saniflo is with you every step of the way! GRAY WATER SANISHOWER SANISWIFT COMMERCIAL RESIDENTIAL Water from sinks, showers, washing machines, HVAC appliances, etc.
SANIPLUS Macerator CONNECTIONS TOILET SINK SHOWER BATHTUB INSTALLATION BEHIND THE TOILET INSTALLATION BEHIND THE WALL APPLICATION Example of installation. Follow local plumbing codes for actual install. RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Saniplus is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer line, or even up to 150 feet away from a soil stack.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Macerator Electrical: 120 V – 60 Hz / 4.5 Amps (Max) Motor: 0.5 HP oil-filled thermally protected motor Capacitor rating: 45 microfarad Operating Temperature: 104°F (110°F Max.) Power cord length: 47–1/2 inches Noise level: ≤ 53 dBA (Lp) (measured at 3 ft.
3 CONNECTIONS TOILET SINK SHOWER BATHTUB INSTALLATION BEHIND THE TOILET Macerator INSTALLATION BEHIND THE WALL APPLICATION Example of installation. Follow local plumbing codes for actual install. RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Saniaccess3 is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer line, or even up to 150 feet away from a soil stack.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Macerator Electrical: 120 V – 60 Hz / 4.5 Amps (Max) Motor: 0.5 HP oil-filled thermally protected motor Capacitor rating: 45 microfarad Operating Temperature: 104°F (110°F Max.) Power cord length: 51 inches Noise level: ≤ 53 dBA (Lp) (measured at 3 ft.
SANIPACK Macerator CONNECTIONS TOILET CLOSE-UP VIEW OF PRODUCT FULL VIEW OF COMPLETE BATHROOM SINK SHOWER APPLICATION Example of installation. Follow local plumbing codes for actual install. RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Sanipack is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer line, or even up to 150 feet away from a soil stack.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Macerator Electrical: 110 V – 60 Hz / 4.5 Amps (Max) Motor: 0.5 HP oil-filled thermally protected motor Capacitor rating: 45 microfarad Operating Temperature: 104°F (110°F Max.) Power cord length: 48 inches Noise level: ≤ 53 dBA (Lp) (measured at 3 ft.
SANIBEST Pro Grinder ® CONNECTIONS TOILET SINK SHOWER BATHTUB LAUNDRY SINK WASHING MACHINE APPLICATIONS RESIDENTIAL COMMERCIAL INSTALLATION BEHIND THE TOILET INSTALLATION BEHIND THE WALL Example of installation. Follow local plumbing codes for actual install. Example of installation. Follow local plumbing codes for actual install. The Sanibest Pro is a 1 HP pump system used to install a complete bathroom up to 25 feet below the sewer line, or even up to 150 feet away from a soil stack.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Grinder Electrical: 120 V – 60 Hz / 9 Amps (Max) Motor: 1 HP oil-filled thermally protected motor Capacitor rating: 60 microfarad Operating Temperature: 104°F (110°F Max.) Power cord length: 49 inches Noise level: ≤ 63 dBA (Lp) (measured at 3 ft.) Discharge pipe diameter: 3⁄4” or 1” Discharge rate at 25 ft: 19 GPM Discharge rate at 3 ft: 38 GPM Shut-off head: 38 ft.
SANIGRIND Pro Grinder ® CONNECTIONS TOILET SINK SHOWER BATHTUB FULL VIEW OF COMPLETE BATHROOM The Sanigrind Pro is a 1 HP pump system used to install a complete bathroom up to 25 feet below the sewer line, or even up to 150 feet away from a soil stack. It incorporates a grinder system which is ideal for uncontrolled environments in both residential and commercial applications (ie. rental unit, offices, warehouses, etc).
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Grinder 60 21d 28a 29 28a 66 28c Electrical: 67 28a 120 V – 60 Hz /9 Amps (Max) Motor: 28b 1 HP oil-filled thermally protected motor Capacitor rating: 31 60 microfarad 28b 21c Operating Temperature: 2a 2c Power cord length: 7 21a Noise level: 24 55 17 63 61a 42 80 8 61c 40 54 3⁄4” or 1” Discharge rate at 25 ft: 19 GPM Discharge rate at 3
SANI CABIN Plumbing contractor added a complete bathroom using a Saniaccess3 macerator. Learn more at: www.saniflo.com www.saniflo.ca CHALLENGE Owner of a plumbing, heating and air-conditioning business in NY wanted to add a bathroom in his home without great expense. He required a system that will be very quiet since the new addition will be very close to a bedroom. SOLUTION The Saniaccess3 was installed for the new addition saving the owner close to $2,000 and more than a day’s worth of labor.
MINING CAMP SFA Saniflo is the key solution for wastewater management in mining camps. SANIBEST PRO Sanibest Pro grinders are used to pump wastewater away to holding tanks without breaking the ground. These 1 HP units are used in commercial applications or in tough environments as they are designed to handle sanitary napkins. CHALLENGE Modular living containers are the only solution for remote temporary mining camps.
SANIBEST PRO TRAILERS Specialty mobile trailer is equipped with three private baths, each offering a shower, sink and toilet. ADA-compliant chamber uses Sanibest Pro heavy-duty grinder system from Saniflo to pump away black and grey water from the three fixtures. SFA Saniflo provides smart solutions in a modular application where traditional gravity drainage is impossible. CHALLENGE Due to the ramp for wheelchair accessibility, the toilet and the shower sit at a lower level than the storage tank.
MOBILE UNIT Saniflo donated two Sanibest Pro units to the humanitarian project, which were distributed by a major wholesaler. SANIBEST PRO SFA Saniflo showers love on homeless With a viable plumbing system installed, the Showering Love bus provides showers and other services to the homeless. With the current setup, the bus can handle up to 40 showers before the tank reaches capacity.
SANI CONNECTIONS TOILET Macerator INSTALLATION BEHIND THE TOILET INSTALLATION BEHIND THE WALL SINK APPLICATION RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. Example of installation. Follow local plumbing codes for actual install. The Saniaccess2 is a 1/2 HP pump system used to install a half-bathroom up to 15 feet below the sewer line, or even up to 150 feet away from a soil stack.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS 800-571-8191 (US) / 800-363-5874 (CDN) ECLATE access 2 usa 2015.pdf 1 2020-01-31 9:48 AM TO PURCHASE PARTS REFERENCED BELOW 28c 67 28c 66 28b 28b 29 21d 21c Pump type: Macerator 21a Electrical: 28b 120 V – 60 Hz / 4.5 Amps (Max) 2c 0.5 HP oil-filled thermally protected motor Motor: 5a 24 4 23 Capacitor rating: 2c 45 microfarad 75 Operating Temperature: 3 63 2a 104°F (110°F Max.
SANICOMPACT Macerator CONNECTIONS FULL VIEW OF COMPLETE BATHROOM SINK APPLICATION Example of installation. Follow local plumbing codes for actual install. RESIDENTIAL The Sanicompact is a self-contained dual-flush toilet system used to install a half-bathroom up to 9 feet below the sewer line, or even up to 120 feet away from a soil stack. It incorporates a macerating system which can handle human waste and toilet paper in residential applications.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Macerator Electrical: 120 V – 60 Hz / 6.8 Amps (Max) Motor: 0.5 HP oil-filled thermally protected motor Capacitor rating: 2 x 45 microfarad Operating Temperature: 95°F (110°F Max.) Power cord length: 59 inches Noise level ≤ 53 dBA (Lp) (measured at 3 ft.
SANICOMPACT COMFORT CONNECTIONS CONNECTION FULL VIEW OF COMPLETE BATHROOM SINK APPLICATION e 0 bl 2 la 20 ai er Av m m Su RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Sanicompact Comfort is a self-contained dual-flush toilet system used to install a half-bathroom up to 9 feet below the sewer line, or even up to 120 feet away from a soil stack. It incorporates a macerating system which can handle human waste and toilet paper in residential applications.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Macerator Electrical: 120 V – 60 Hz / 6.8 Amps (Max) Motor: 0.5 HP oil-filled thermally protected motor Capacitor rating: 2 x 45 microfarad Operating Temperature: 95°F (110°F Max.) Power cord length: 59 inches Noise level ≤ 53 dBA (Lp) (measured at 3 ft.
SANISTAR CONNECTIONS CONNECTION Macerator FULL VIEW OF COMPLETE BATHROOM SINK APPLICATION RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Sanistar is a self-contained dual-flush toilet system used to install a half-bathroom up to 9 feet below the sewer line, or even up to 120 feet away from a soil stack. It incorporates a macerating system which can handle human waste and toilet paper in residential applications.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Macerator Electrical: 120 V – 60 Hz / 9 Amps (Max) Motor: 0.4 HP oil-filled thermally protected motor Capacitor rating: 2 x 25 microfarad Operating Temperature: 95°F (110°F Max.) Power cord length: 51-1/2” inches Noise level ≤ 53 dBA (Lp) (measured at 3 ft.
SANISTAR HURRICANE RECONSTRUCTION Homeowner created a new half-bathroom below the drain using Saniflo’s abovefloor macerating technology while saving money in the process. Self-contained system allowed the installation to be completed in less than a day. SFA Saniflo provides homeowner with money-saving solution in wake of hurricane Learn more at: www.saniflo.com www.saniflo.ca CHALLENGE The construction of a new half-bathroom below the main drain line without the use of below-ground pump systems.
KARAOKE BARS SANICOMPACT Many karaoke bars have adopted the flexibility of macerators to design comfortable rooms with private restrooms. These space-saving self-contained toilets are cost effective and very efficient. SFA Saniflo helps installation of additional toilets in tight spaces. CHALLENGE Owners of these karaoke entertainment bars often want to use empty small spaces in high-rise buildings to install restrooms. Space is limited for the construction and installation of a standard toilet.
SANICOM1Drain Pump CONNECTIONS DISHWASHER SINK SHOWER BATHTUB LAUNDRY SINK WASHING MACHINE APPLICATIONS Example of installation. Follow local plumbing codes for actual install. COMMERCIAL The Sanicom 1 drain pump is used to pump gray water away from a variety of fixtures in commercial applications. The system is able to discharge the waste up to 25 feet vertical and/or 250 feet horizontal.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Drain pump Electrical: 120 V – 60 Hz / 10 Amps (Max) Motor: 1 HP oil-filled thermally protected motor Capacitor rating: 45 microfarad Operating Temperature: 194°F Max. Power cord length: 50 inches Noise level: ≤ 68 dBA (Lp) (measured at 3 ft.) Discharge pipe diameter: 1” Discharge rate at 25 ft: 17 GPM Discharge rate at 3 ft: 33 GPM Shut-off head: 53 ft.
SANIVITE Drain Pump CONNECTIONS DISHWASHER SINK SHOWER BATHTUB LAUNDRY WASHING SINK MACHINE APPLICATIONS RESIDENTIAL COMMERCIAL Example of installation. Follow local plumbing codes for actual install. The Sanivite drain pump is used to pump gray water away from a variety of fixtures in commercial and residential applications. The system is able to discharge the waste up to 16 feet vertical and/or 150 feet horizontal.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Drain pump Electrical: 120 V – 60 Hz / 4.5 Amps (Max)* Motor: 0.4 HP oil-filled thermally protected motor Capacitor rating: 18 microfarad Operating Temperature: 140°F Power cord length: 42–1/2 inches Noise level: ≤ 44 dBA (Lp) (measured at 3 ft.) Discharge pipe diameter: 1” - 1–1/2” Discharge rate at 16 ft: 18 GPM Discharge rate at 3 ft: 29 GPM Shut-off head: 30 ft.
SANISWIFT Drain Pump CONNECTIONS SHOWER SINK DISHWASHER LAUNDRY APPLICATION RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Saniswift drain pump is used to pump gray water away from a variety of fixtures in residential applications. The system is able to discharge the waste up to 14 feet vertical and/or 140 feet horizontal. Discharges the waste through either a 1”, 1-1/4” or 1-1/2” rigid pipe.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Drain pump Electrical: 120 V – 60 Hz / 4.5 Amps (Max)* Motor: 0.3 HP oil-filled thermally protected motor Capacitor rating: 30 microfarad Operating Temperature: 140°F Power cord length: 48 inches Noise level: ≤ 44 dBA (Lp) (measured at 3 ft.) Discharge pipe diameter: 1”- 1–1/2” Discharge rate at 14 ft: 18 GPM Discharge rate at 3 ft: 24 GPM Shut-off head: 25 ft.
SANISHOWER Drain Pump CONNECTIONS SHOWER SINK APPLICATION RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Sanishower drain pump is used to pump gray water away from a variety of fixtures in residential applications. The system is able to discharge the waste up to 12 feet vertical and/or 100 feet horizontal. Discharges the waste through a 3/4” or 1” rigid pipe. A non-return valve is included on the discharge fitting assembly provided with the system.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Drain Pump Electrical: 120 V – 60 Hz / 5.5 Amps (Max) Motor: 0.2 HP oil-filled thermally protected motor Capacitor rating: 25 microfarad Operating Temperature: 104°F (110°F Max.) Power cord length: 48–1/2” Noise level: ≤ 44 dBA (Lp) (measured at 3 ft.
SANICOM 1 HYDROPONICS SFA Saniflo provides efficient pumping system for demanding application. CHALLENGE Finding a product with low-level inlets to remove gray water from their cannabis production chambers. Able to handle the overflow from cannabis discharge and harsh condensate from the boiler/ humidifier The vertical evacuation of discharge needed to be at 25 ft of head Required a product capable of lasting over 50,000 cycles per year.
RESTAURANT SANICOM1 SFA Saniflo provides smart solutions in commercial kitchens where traditional gravity drainage is impossible. The powerful 1-HP Sanicom I pump is used to evacuate hot water from commercial kitchens. The perfect solution for applications where the water temperature can cause problems. Learn more at: www.saniflo.com www.saniflo.ca CHALLENGE Kitchen ovens required a connection to the main sewer in order to discharge wastewater created by steam and by automatic self-cleaning cycle.
SANIVITE COFFEE SHOP SFA Saniflo provides a more reliable solution in popular coffee shops. The very powerful, yet quiet and compact Sanivite pump is used to evacuate gray water for a sink addition. This heavy-duty drain pump is the perfect solution when no drain line is present. CHALLENGE Existing submersible pumps gave off odors and failed regularly affecting everyday activity. Need to substitute existing system with reliable product that would be required to pump gray water from a sink and dishwasher.
DENTIST SANISHOWER SFA Saniflo helps with the redesign of a new dentist office. When the owner of a dentist office needed to add dental chairs to a new location, several Sanishower drain pumps made it possible. Learn more at: www.saniflo.com CHALLENGE The existing sewer lines were too far away from the desired chair location and traditional gravity was an expensive proposition.
SANICONDENS Condensate Pump CONNECTIONS AIR CONDITIONER BOILER HVAC APPLICATIONS RESIDENTIAL COMMERCIAL Example of installation. Follow local plumbing codes for actual install. The Sanicondens is a small pump used to pump condensate from condensing boilers, HVAC systems, water heater systems, etc. The Sanicondens will pump condensate waste up to 15 feet in height and/or 150 feet away from a soil stack. Discharges the condensate waste through a 3 ⁄ 8” vinyl tube.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Condensate Pump Electrical: 120 V – 60 Hz / 1.5 Amps (Max) Motor: 1/30 HP oil-filled thermally protected motor Operating Temperature: 160°F Max Power cord length: 60 inches Noise level: ≤ 44 dBA (Lp) (measured at 3 ft.
SANICONDENS BEST CONNECTIONS AIR CONDITIONER BOILER HVAC CONDENSATE PUMP/NEUTRALIZER APPLICATIONS RESIDENTIAL COMMERCIAL Example of installation. Follow local plumbing codes for actual install. The Sanicondens Best is a pump used to neutralize and pump condensate from condensing boilers, HVAC systems, water heater systems, etc. The Sanicondens Best will pump condensate waste up to 15 feet in height and/or 150 feet away from a soil stack. Discharges the condensate waste through a 3 ⁄ 8” vinyl tube.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Condensate pump Electrical: 120 V – 60 Hz / 1.5 Amps (Max) Motor: 1/30 HP oil-filled thermally protected motor Operating Temperature: 160°F Max Power cord length: 61–1/2 inches Noise level: ≤ 44 dBA (Lp) (measured at 3 ft.
SANICONDENS BEST FLAT CONNECTIONS AIR CONDITIONER BOILER HVAC APPLICATIONS Example of installation. Follow local plumbing codes for actual install. RESIDENTIAL COMMERCIAL The Sanicondens Best Flat is a low profile pump used to neutralize and pump condensate from condensing boilers, HVAC systems, water heater systems, etc. The Sanicondens Best Flat will pump condensate waste up to 15 feet in height and/or 150 feet away from a soil stack. Discharges the condensate waste through a 3 ⁄ 8” vinyl tube.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: 800-571-8191 (US) / 800-363-5874 (CDN) Condensate pump 23 Electrical: 1 120 V – 60 Hz / 1.5 Amps (Max) Motor: 2 1/30 HP oil-filled thermally protected motor Operating Temperature: 160°F Max Power cord length: 61–1/2 inches 3 Noise level: ≤ 44 dBA (Lp) (measured at 3 ft.
SANINEUTRAL CONNECTIONS AIR CONDITIONER BOILER HVAC APPLICATIONS Example of installation. Follow local plumbing codes for actual install. RESIDENTIAL COMMERCIAL Example of installation. Follow local plumbing codes for actual install. IS A CONDENSATE NEUTRALIZER NECESSARY? Yes, typical condensate from a condensing boiler has a pH level of 3.2 to 4.5, which is acidic enough to leave stains, kill shrubs, and eat away cast iron drainage systems.
SANIACCESSORIES Extension pipe Sanialarm PART NO 030 PART NO 050 This solution alerts homeowners of high water levels inside the pump. The Sanialarm helps prevent inappropriate use and encourages prompt intervention. The Sanialarm has a level pressure switch that triggers an alarm fixed on the top of the unit if the volume of water exceeds the maximum allowed level. The alarm emits a continuous 80 dB warning sound until it is switched off or the problem is rectified.
CONNECTIONS CONNECTIONS TOILET BATHTUB DISHWASHER SINK SHOWER BAR SINK LAUNDRY SINK WASHING MACHINE APPLICATIONS RESIDENTIAL SANICUBIC 1 Grinder ® INSTALLATION ABOVE GROUND Example of installation. Follow local plumbing codes for actual install. INSTALLATION BELOW THE GROUND Example of installation. Follow local plumbing codes for actual install.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Grinder Electrical: 120 V – 60 Hz / 4.5 Amps (Max) 220 240 V – 60 Hz (Part# 069) Motor: 1 HP oil-filled thermally protected motor Capacitor rating: 60 microfarad Operating Temperature: 158°F Power cord length: 80 inches Noise level: ≤ 68 dBA (Lp) (measured at 3 ft.) Discharge pipe diameter: 1–1/2” Discharge rate at 36 ft: 26 GPM Discharge rate at 3 ft: 50 GPM Shut-off head: 45 ft.
CONNECTIONS CONNECTIONS TOILET BATHTUB DISHWASHER SINK SHOWER BAR SINK LAUNDRY SINK WASHING MACHINE APPLICATIONS COMMERCIAL SANICUBIC 2 Grinder ® INSTALLATION ABOVE GROUND Example of installation. Follow local plumbing codes for actual install. INSTALLATION BELOW THE GROUND Example of installation. Follow local plumbing codes for actual install.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Grinder Electrical: 220-240 V (208V min) - 60 Hz / 13 Amps (Max) Motor: 2 x 1 HP oil-filled thermally protected motor Capacitor rating: 2 x 30 microfarad Operating Temperature: 158°F Power cord length: 72 inches Noise level: ≤ 68 dBA (Lp) (measured at 3 ft.
CONNECTIONS SANICUBIC 1 VX Vortex ® CONNECTIONS TOILET BATHTUB DISHWASHER SINK SHOWER BAR SINK LAUNDRY SINK WASHING MACHINE APPLICATIONS RESIDENTIAL Example of installation. Follow local plumbing codes for actual install. The Sanicubic 1 VX is a 1.5 HP heavy duty simplex vortex system used to pump away waste water from several bathrooms and fixtures from an entire building structure.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Vortex Electrical: 220-240 V (208V min) - 60 Hz / 12 Amps (Max) Motor: 1.5 HP oil-filled thermally protected motor Capacitor rating: 30 microfarad Operating Temperature: 158°F Power cord length: 98 inches Noise level: ≤ 70 dBA (Lp) (measured at 3 ft.
CONNECTIONS SANICUBIC 2 VX Vortex ® CONNECTIONS TOILET BATHTUB DISHWASHER SINK SHOWER BAR SINK LAUNDRY SINK WASHING MACHINE APPLICATIONS COMMERCIAL Example of installation. Follow local plumbing codes for actual install. The Sanicubic 2 VX is a 1.5 HP heavy duty duplex vortex system used to pump away waste water from several bathrooms and fixtures from an entire building structure.
PLEASE CALL US TOLL-FREE AT TECHNICAL SPECIFICATIONS TO PURCHASE PARTS REFERENCED BELOW Pump type: Vortex Electrical: 220-240 V (208V min) - 60 Hz / 12 Amps (Max) Motor: 2 x 1.5 HP oil-filled thermally protected motor Capacitor rating: 2 x 30 microfarad Operating Temperature: 158°F Power cord length: 98 inches Noise level: ≤ 70 dBA (Lp) (measured at 3 ft.
SANICUBIC 2 ® Saniflo overcame the lack of drainage and long sewer line in the historic Middletown facility by using an innovative system to pump and process waste without digging. Factory Warehouse CHALLENGE When the building was constructed in the early 1900s, the sewage was disposed in the nearby river which is now prohibited. Breaking the concrete to install a pump system was not possible as the land was too contaminated.
UNIVERSITY SANICUBIC 2 ® SFA Saniflo systems replace failing sewage pumps at Fordham university in NYC Sewage ejector systems were used at the main library to discharge the wastewater from several toilets into their main sewer line. One Sanicubic 2 grinder pump was installed to replace these failing sewage systems. Learn more at: www.saniflo.com www.saniflo.ca CHALLENGE Existing sewage systems were regularly clogging up.
SANICUBIC 1MODULAR HOMES Grinder systems were installed for modular trailers used by construction crews. The need for a powerful yet compact evacuation system made the Sanicubic a perfect fit for this application. CHALLENGE More than 300 workers live in modular suites equipped with bathrooms and kitchens. An effective solution was needed to remove the wastewater to a holding tank over 200 feet away. Cost of excavation and installing large diameter pipes with the required pitch was not cost effective.
POOL SIDE CABANA Shower enclosures, coupled with Saniflo above-floor plumbing systems, are making outdoor facilities simpler and more affordable. SANICUBIC 1 “The ability to install an outdoor bathroom simply and affordably opens up a whole range of possibilities for customers not wishing to spend a fortune on improving their lifestyles.” CHALLENGE Finding a product to allow the installation of a toilet, sink or shower in the outdoor bathroom enclosure. Learn more at: www.saniflo.com www.saniflo.
SANICUBIC1 VESSEL Saniflo Sanicubic 1 lift station provides effective, cost-saving plumbing solution for research vessel in the Caribbean. CHALLENGE Find an effective alternative: a system that could accommodate the vessel’s four toilets and with the pumping power to handle the vertical distance from the heads to the vessel’s blackwater tank 6 feet above the waste lines. SOLUTION To perform that task, MANTA installed a Sanicubic 1 Simplex Grinder System, donated by Saniflo.
CHURCH SANICUBIC 2 Oneonta Assembly of God Church was facing the specter of an expensive plumbing installation for its new building expansion. Fortunately, a good Samaritan plumber proposed and installed a duplex grinding solution from Saniflo that saved the house of worship nearly $30,000. ® A Plumbing Miracle: Grinder Pump Saves Church $30K Learn more at: www.saniflo.com www.saniflo.
EXTERNAL UNITS INSTALLATION TIPS AND GUIDELINES B VENT CONNECTION DISCHARGE CONNECTION TOILET CONNECTION D A C INLET INLET D 4 System comes equipped with a plastic discharge elbow with built-in check valve, a rubber step-down fitting to adapt to the discharge pipe and all clamps needed to secure this connection. (different design for Saniplus and Sanipack) 4 First horizontal run cannot exceed more than 24” prior to the vertical run. It’s also not recommended to install long diagonal runs.
LIFT STATIONS INSTALLATION TIPS AND GUIDELINES DISCHARGE CONNECTION INLETS D INLET VENT CONNECTION INLET A D B D C Scan with your smartphone to watch a video clip of the Sanicubic1. CONTROL/ALARM 4 A rubber coupling along with clamps is provided to connect to the 1–1/2” discharge pipe. A non-return valve (dual valves for Sanicubic 2) is built into the discharge assembly of the pump.
SELF-CONTAINED UNITS INSTALLATION TIPS AND GUIDELINES D A D WATER SUPPLY DISCHARGE CONNECTION INLET Scan with your smartphone to watch a video clip of the Sanicompact. 4 System comes equipped with a plastic discharge elbow with built-in check valve, a rubber step-down fitting to adapt to the discharge pipe and all clamps needed to secure this connection. 4 First horizontal run cannot exceed more than 24” prior to the vertical run. It’s also not recommended to install diagonal runs.
DRAIN PUMPS INSTALLATION TIPS AND GUIDELINES DISCHARGE CONNECTION B C A VENT CONNECTION INLETS C INLETS C INLETS 4 Comes with a plastic discharge fitting with built-in check valve, a rubber step-down fitting to adapt to the discharge pipe and all clamps needed. 4 First horizontal run cannot exceed more than 24” prior to the vertical run. It’s also not recommended to install diagonal runs.
REASONS WHY YOU SHOULDN’T CONSIDER BREAKING THE CONCRETE R ED FLAGS TO REMEMBER: Cutting concrete undermines structural integrity: Any time you cut into a slab, you decrease the foundational integrity of the building — no matter how close to a perfect cut you make. You may be able to patch the hole you create well enough to eliminate any aesthetic objections.
SANIFLO'S ADVANTAGES AND BENEFITS Want to turn an unfinished room into a finished bathroom or laundry room? Plan your project using the tools provided on our website to choose the best system for your application. ??? You can find answers to frequently asked questions by visiting our website or by calling our live toll free number and speaking with a certified technician.
Before USA – Toll Free: 800-571-8191 www.saniflo.com © SFA Saniflo Inc. © SFA Saniflo Inc. © SFA Saniflo Inc. © SFA Saniflo Inc. Before After After Canada – Toll Free: 800-363-5874 www.saniflo.ca © 2020, SFA Saniflo Inc., All Rights Reserved.