INS_TMC-GSFP[POE][M] 08/12/19 PAGE 6
INSTALLATION AND OPERATION MANUAL TMC-GSFP SERIES
FIGURE A
Dimensions are for a small size module
FIGURE B
Dimensions are for a standard one slot module
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should
be installed in dry locations protected from extremes of temperature and
humidity.
SBP-C14 / SBP-C03 CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power
off to the rack, Hanwha recommends that the
power supply be turned off and that the rack power supply is
disconnected from any power source. Note: Remove electrical connector
before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the
card guides in the rack until the edge connector at the back of the card
seats in the corresponding slot in the rack’s connector panel. Seating
may require thumb pressure on the top and bottom of the card’s front
panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideration should
be given to installing the equipment in an environment compatible
with the maximum ambient temperature (Tma) specified by the
manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be
such that the amount of air flow required for safe operation of the
equipment is not compromised.
.156 [3.96 mm]
.313 [7.95 mm]