Installation manual

CHAPTER 3. Specification of OfficeServ 7400
3-12
© SAMSUNG Electronics Co., Ltd.
3.2.2 Transmission Characteristics
y Attenuation
Attenuation between subscribers: Less than 6 dB
Attenuation between the subscriber and local trunk line: Less than 0.5 dB
y Characteristic resistance of the line: 600
y Weighted noise: Less than -65 dBm
y Crosstalk attenuation: Less than -68 dBm
y Frequency band: 300~3400 Hz
y Insulation resistance: More than 1 M
3.2.3 Line Conditions
y Length for installation:
Regular phones: Up to 1 km (When the AWG #24 cable is used)
Digital phones: Up to 400 m (When the AWG #24 cable is used)
Door phones: Up to 400 m (When the AWG #24 cable is used)
AOMs: Up to 400 m (When the AWG #24 cable is used)
y Distance between PLIM and SMT-R2000: Up to 100 m (when an Ethernet cable is used)
y Leakage resistance between lines: More than 20 K
y Leakage resistance between grounds: More than 20 K