PROSTAR DCS COMPACT TECHNICAL MANUAL T A B L E INSTALLATION TABLE OF CONTENTS JUNE 2001 O F Table of Contents C O N T E N T S INSTALLATION SECTION PART DESCRIPTION PAGE 1 SITE REQUIREMENTS ................................................................... 1–1 2 INSTALLATION OF BASIC KSU AND EXPANSION KIT 3 4 HOME PAGE 2.1 UNPACKING AND INSPECTION .................................................. 2–1 2.2 KEY SERVICE UNIT INSTALLATION ............................................ 2–1 2.
PROSTAR DCS COMPACT TECHNICAL MANUAL 5 6 INSTALLATION TABLE OF CONTENTS JANUARY 2002 CONNECTING TELCO CIRCUITS 5.1 SAFETY PRECAUTIONS .............................................................. 5–1 5.2 LOOP START LINES ..................................................................... 5–1 5.3 OFF PREMISE EXTENSIONS (OPX) ............................................ 5–1 5.4 E&M TIE LINES ............................................................................
PROSTAR DCS COMPACT TECHNICAL MANUAL 9 10 11 12 13 INSTALLATION TABLE OF CONTENTS JUNE 2001 CHANGING SOFTWARE 9.1 ACCESSING THE EPROMS ......................................................... 9–1 9.2 REPLACING THE EPROMS ......................................................... 9–1 INSTALLING CALLER ID 10.1 GENERAL INFORMATION ......................................................... 10–1 10.2 INSTALLING ON A NEW SYSTEM ............................................. 10–2 10.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 1 DECEMBER 1994 Table of Contents PART 1. SITE REQUIREMENTS When planning the installation of the DCS COMPACT, choose a site that meets the following requirements: z z z z z z z z Select a location for the key service unit (KSU) that has enough space for easy installation and adequate lighting (see Figure 1–1). Select a location that will minimize cable lengths. See the Cable Requirements table below.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 1 DECEMBER 1994 HOME PAGE Table of Contents 22.5" 5" 14.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 JUNE 1995 PART 2. INSTALLATION OF BASIC KSU AND EXPANSION KIT 2.1 UNPACKING AND INSPECTION After unpacking the KSU, inspect for signs of physical damage. If any damage is detected, do not attempt to install. Contact Samsung Telecommunications America, Technical Support Department.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 JUNE 1995 HOME PAGE Table of Contents 2.4 GROUNDING In order to comply with the revised UL 1459 Telephone Equipment document, the following paragraphs must be incorporated into this installation manual. “UL 1459 Paragraph 66. To be included in Installation Instructions. “66.1.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 JUNE 1995 supplementary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers in Part K of Article 250 of the National Electrical Code ANSI/NFPA 70. Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reliably connected to the electrical service equipment ground.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 JUNE 1995 HOME PAGE Table of Contents 2.5 MDF CABLING All connections to the DCS COMPACT system are made by way of a customerprovided main distribution frame (MDF). The KSU and expansion kit are each connected to the MDF using a 25 pair female amphenol-type cable. These cables can be routed into the KSU cabinet from below. Label each cable to correspond with the connector numbers (see Figure 2–4).
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 DECEMBER 1994 HOME PAGE Table of Contents UPPER MOUNTING HOLE POWER ON OFF _ 0 LOWER MOUNTING HOLES KSU MOUNTING HOLES FIGURE 2– 1
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 FEBRUARY 1996 HOME PAGE Table of Contents SCR5 SCR1 BACKPLANE MOUNTING SCREWS P2 SCR2 SCR3 LOCATION OF BACKPLANE MOUNTING SCREWS SCR4 FIGURE 2– 2 RACK MOUNTING SCREWS SCR5 SCR1 P2 SCR2 SCR3 LOCATION OF RACK MOUNTING SCREWS SCR4 FIGURE 2– 3
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 2 DECEMBER 1994 HOME PAGE Table of Contents SCR1 SCR5 EXPANSION SLOT 3 EXPANSION SLOT 2 EXPANSION SLOT 1 P2 SCR2 SCR3 SCR4 4 COP SLOT PSU RAM PACK SLOT 2 SLI SLOT MISC SLOT GROUND LUG THIRD WIRE GROUND KEY SERVICE UNIT GROUNDING TO POWER OUTLET FIGURE 2– 4
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 DECEMBER 1994 PART 3. INSTALLING PRINTED CIRCUIT CARDS Unpack and inspect each card before installing. Check for signs of physical damage. If any damage is detected, do not attempt to install. Contact Samsung Technical Support immediately. 3.1 RAM PACK (Figure 3– 2) Select the appropriate type of RAM pack for the system.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 NOVEMBER 1997 Table of Contents 3.6 2 X 4 DLI CARD (Figure 3– 7) There are no options to select on this card. Insert the 2 X 4 DLI card into any slot on the expansion backplane (see Figure 3–6). Push firmly in the middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector. 3.7 2 X 4 SLI CARD (Figure 3– 7) There are no options to select on this card.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 DECEMBER 1994 HOME PAGE Table of Contents 4 COP SLOT PSU RAM PACK SLOT 2 SLI SLOT MISC SLOT 408 KSU SLOT POSITIONS FIGURE 3– 1
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 DECEMBER 1994 HOME PAGE Table of Contents RE SE T B OFACK UP F ON RU UP N DCS COMPACT RAM PACK FIGURE 3– 2
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 DECEMBER 1994 HOME PAGE Table of Contents 4TRK R405 R305 C402 D402 D404 R205 C302 D304 D204 D302 R105 C202 C102 D401 D104 D202 D301 D201 D101 U301 U201 U101 D102 U403 U402 U303 U302 D403 C404 C407 U203 U202 D303 C304 C307 RLY8 C204 C207 RLY7 T3 C201 RLY3 DSS2 DSS7 DSS5 DSS3 DSS1 C101 RLY2 RLY1 C1 BAR CODE P4 4 CO PROTECTION CARD RW3 BAR CODE P3 FIGURE 3– 3 DCS COMPACT (2SLC) C104 C312 C311 DSS4 T1
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 DECEMBER 1994 HOME PAGE Table of Contents PORT 2 TNR1 P7 U6 C10 BAR CODE U5 Y2 C12 U4 U7 T1 C14 C15 C17 U1 Y1 TNR4 U8 TNR3 TNR2 U3 U2 P1 P2 PORT 1 DCS COMPACT (MISC) MISC CARD FIGURE 3– 5
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 DECEMBER 1994 HOME PAGE Table of Contents SCR1 SCR5 EXPANSION SLOT 3 EXPANSION SLOT 2 EXPANSION SLOT 1 P2 SCR2 SCR3 SCR4 4 COP SLOT PSU RAM PACK SLOT 2 SLI SLOT MISC SLOT EXPANSION KIT INSTALLED IN KSU FIGURE 3– 6
2 X 4 DLI CARD AND 2 X 4 SLI CARD C701 Q701 C710 C714 U702 U1 R700 C700 C3 U2 U3 C1 C5 C3 C5 DCS COMPACT (204SLT) C708 BAR CODE R719 T701 C709 C712 C711 BAR CODE DCS COMPACT (204DLI) U1 C510 U2 C310 U602 C507 C307 C402 PS1 U502 U402 U302 T1 U4 T2 HYB5 C502 PS2 U5 P1 T3 T6 T5 T4 T3 P1 C602 PS31 U6 C611 C604 C504 C511 C411 C702 PS4 C304 C404 C311 T4 U7 R603 R503 R403 R303 C202 RL4 T6 C601 HYB4 HYB3 HYB2 HYB1 RL3 C501 RL8 C602 RL7 C
BAR CODE U1 C110 U2 U3 DCS COMPACT (2E&M/4DLI) T4 PS4 C402 U4 PS5 C502 2 E&M / 4 DLI CARD J3 FG NO 48 48 NC T5 T1 T5 T1 FG FG NO 48 48 NC RLY1 T3 DSS4 C212 DSS3 C289 DSS2 P2 DSS1 RLY2 T3 U23 TYPE RLY1 R203 R201 R301 U22 U21 J4 TYPE C112 R303 U33 PS32 C100 PS7 C702 U31 U32 PS31 P1 PS6 C602 T7 U7 PS22 J2 FG T6 U6 PS21 J1 J3 RLY2 T5 U5 PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 3 NOVEMBER 1997 J1 J2 J4 FIGURE 3– 8 HOME PAGE Table
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 4 NOVEMBER 1997 PART 4. POWER UP PROCEDURES 4.1 CONNECT POWER TO THE SYSTEM During the initial installation, it is best to verify proper system operation before plugging in any amphenol-type cables to the MDF. If you have already plugged the cables in, unplug them at this time. Verify that the AC voltage at the dedicated electrical outlet is in the range of 82–132 Volts AC.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 4 NOVEMBER 1997 4.4 DEFAULT TRUNK AND STATION NUMBERING Upon initial power up, the CPU reads each slot for the existence of a card and identifies the type of card. It stores this as the default configuration. The system assigns trunk numbers beginning with 701 and continues to 704 for a basic KSU or to 710 for a fully equipped KSU. Station numbers are assigned in the same manner.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 5 NOVEMBER 1997 PART 5. CONNECTING TELCO CIRCUITS 5.1 SAFETY PRECAUTIONS To limit the risk of personal injury, always follow these precautions before connecting TELCO circuits: a. Never install telephone wiring during a lightning storm. b. Never install telephone jacks in a wet location unless the jack is specifically designed for wet locations. c.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 5 DECEMBER 1994 Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 FUNCTION CIRCUIT C.O. TIP 1 C.O. RING C.O. TIP TERM COLOR PIN 1 W-BL 26 2 BL-W 1 3 W-O 27 4 O-W 2 5 W-GN 28 6 GN-W 3 7 W-BR 29 8 BR-W 4 2 C.O. RING TELCO-PROVIDED NETWORK ACCESS JACK RJ 11C RJ 14C RJ 21X CONNECT TO ANY CO CIRCUIT ON THE BASIC KSU. C.O. TIP 3 C.O. RING C.O. TIP 4 C.O.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 5 NOVEMBER 1997 Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION KIT P2 FUNCTION CIRCUIT TERM COLOR PIN 1 W-BL 26 2 BL-W 1 3 W-O 27 4 O-W 2 C.O. TIP 5 W-GN 28 C.O.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 5 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 FUNCTION CIRCUIT SLT TIP TERM COLOR PIN 29 BK-SL 40 30 SL-BK 15 31 Y-BL 41 32 BL-Y 16 1 SLT RING SLT TIP 2 SLT RING TELCO-PROVIDED NETWORK ACCESS JACK RJ 11C RJ 14C RJ 21X CONNECT TO ANY CIRCUIT ON THE 2 SLI CARD.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 5 NOVEMBER 1997 Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION KIT P2 FUNCTION CIRCUIT TERM COLOR PIN 1 W-BL 26 2 BL-W 1 E 3 W-O 27 M 4 O-W 2 C.O. TIP 5 W-GN 28 C.O.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JANUARY 2002 PART 6. CONNECTING STATION EQUIPMENT 6.1 SAFETY PRECAUTIONS To limit the risk of personal injury, always follow these precautions before connecting telephone circuits: a. Never install telephone wiring during a lightning storm. b. Never install telephone jacks in a wet location unless the jack is specifically designed for wet locations. c.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JANUARY 2002 When a customer-provided electric door release is installed, cross-connect the corresponding door release contacts on the DPIM to the door lock mechanism (see Figures 6–7 and 6–8). Use MMC 501 to program the duration of the contact closure as required. See the user guides for door lock release operation. The door release contacts on the DPIM are to be used for low voltage relay control only. The contacts are rated at 24 VDC-1 amp.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JUNE 2001 Use screw holes 1 and 2 to attach the base wedge to a standard electrical outlet box. OR Use screw holes 1 and 3 to attach to a standard telephone wall-mount plate with locking pins. This method can cause the keyset to wobble as the keyset feet do not fit securely to the mounting surface. 6.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR TERM 31 R-BL 11 6 BL-R 12 32 R-O 13 7 O-R 14 33 R-GN 15 8 GN-R 16 34 R-BR 17 9 BR-R 18 35 R-S 19 10 S-R 20 36 BK-BL 21 CIRCUIT FUNCTION DLI TIP 1 DLI RING DLI TIP 2 3 DLI RING DLI TIP ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG R G BK Y W BL DLI RING 4 DLI TIP DLI RING 5 DLI TIP DLI RING DLI TIP 6 11
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION KIT P2 PIN COLOR TERM 39 BK-BR 27 14 BR-BK 28 40 BK-SL 29 CIRCUIT 9 SL-BK DLI TIP DLI RING DLI TIP 10 15 FUNCTION 30 DLI RING DLI TIP 41 Y-BL 31 16 BL-Y 32 DLI RING 42 Y-O 33 DLI TIP 17 O-Y 34 DLI RING 43 Y-GR 35 DLI TIP 18 GR-Y 36 44 Y-BR 37 19 BR-Y 38 45 Y-SL 39 20 SL-Y 40 46 V-BL 41 11 12 13 BL-V 42 47 V-O 43 22 O-V 44
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR TERM 31 R-BL 11 6 BL-R 12 32 R-O 13 CIRCUIT 1 FUNCTION DLI TIP DLI RING DLI TIP 2 DLI RING 7 O-R 14 33 R-GN 15 8 GN-R 16 DLI RING 34 R-BR 17 DLI TIP 9 BR-R 18 35 R-S 19 10 S-R 20 36 BK-BL 21 DLI TIP 3 11 BL-BK 22 37 BK-O 23 12 O-BK 24 38 BK-GR 25 4 GR-BK 26 R G BK Y W BL DLI RING 5 DLI T
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION KIT P2 PIN COLOR TERM 39 BK-BR 27 14 BR-BK 28 40 BK-SL 29 CIRCUIT 9 FUNCTION DLI TIP DLI RING DLI TIP 10 DLI RING 15 SL-BK 30 41 Y-BL 31 16 BL-Y 32 DLI RING 42 Y-O 33 DLI TIP 17 O-Y 34 43 Y-GR 35 18 GR-Y 36 44 Y-BR 37 19 BR-Y 38 DLI TIP 11 ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG R G BK Y W BL
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR 40 BK-SL TERM CIRCUIT 29 FUNCTION SLT TIP 1 15 SL-BK 30 41 Y-BL 31 16 BL-Y 32 SLT RING SLT TIP 2 SLT RING ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG R G BK Y W BL 1 2 3 4 5 6 CONNECT TO ANY CIRCUIT ON THE 2 SLI CARD.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION KIT P2 PIN COLOR TERM CIRCUIT 39 BK-BR 27 14 BR-BK 28 40 BK-SL 29 15 SL-BK 30 SLI RING 41 Y-BL 31 SLI TIP 16 BL-Y 32 42 Y-O 33 17 O-Y 34 SLI RING 43 Y-GR 35 SLI TIP 18 GR-Y 36 44 Y-BR 37 19 BR-Y 38 45 Y-SL 39 9 SL-Y 40 46 V-BL 41 SLI TIP SLI RING 10 11 SLI TIP ONE PAIR TWISTED SHEATHED STATION CABLE 24
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR TERM 31 R-BL 11 CIRCUIT FUNCTION DLI TIP 1 DLI RING 6 BL-R 12 32 R-O 13 7 O-R 14 33 R-GN 15 8 GN-R 16 DLI RING 34 R-BR 17 DLI TIP 9 BR-R 18 DLI RING 35 R-S 19 DLI TIP 10 S-R 20 36 BK-BL 21 DLI TIP 2 3 4 5 DLI RING DLI TIP ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG R G BK Y W BL DLI RING DLI TIP 1
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 DECEMBER 1994 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION KIT P2 PIN COLOR TERM 39 BK-BR 27 CIRCUIT FUNCTION DLI TIP 9 14 BR-BK 28 40 BK-SL 29 15 SL-BK 30 DLI RING 41 Y-BL 31 DLI TIP 16 BL-Y 32 DLI RING 42 Y-O 33 DLI TIP 17 O-Y 34 43 Y-GR 35 18 GR-Y 36 44 Y-BR 37 19 BR-Y 38 DLI RING 45 Y-SL 39 DLI TIP 20 SL-Y 40 46 V-BL 41 21 BL-V 42 47 V-O 43 DLI RING 10 11 DLI TIP O-V 44 48
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JUNE 2001 HOME PAGE Table of Contents 1 5 4 2 3 HOLES FOR MOUNTING SCREWS NOTE: THE DIRECTORY CARD SLIDE TRAY IS NOT USED WHEN THE KEYSET IS WALL-MOUNTED.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JUNE 2001 HOME PAGE Table of Contents 1 2 3 USED FOR ATTACHING AOMS WITH CONNECTOR CLIP HOLES FOR MOUNTING SCREWS NOTE: THE DIRECTORY CARD SLIDE TRAY IS NOT USED WHEN THE KEYSET IS WALL-MOUNTED.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JANUARY 2002 HOME PAGE Table of Contents 1 2 3 WALL-MOUNTING AN iDCS KEYSET FIGURE6–11 6 -7 FIGURE
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 6 JUNE 2001 HOME PAGE GROOVE FOR ADDITIONAL CONNECTOR CLIP METAL CONNECTOR CLIP 24B / 12B ULTRA BASE WEDGE AOM ULTRA BASE WEDGE Table of Contents ATTACHING 24B/12B TO AOM FIGURE6–12 6 -7 FIGURE
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 PART 7. CONNECTING OPTIONAL EQUIPMENT 7.1 MUSIC ON HOLD/BACKGROUND MUSIC Connect each customer-provided music source to the music input on the KSU connecting block (see Figure 7–1). The music input has internal automatic gain compensation features.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 The basic steps for common bell operation are the following: a. b. c. d. Wire the loud ringing device to the common bell control contact pair. Program the contacts for continuous or steady operation. Program the hunt group to include the common bell. Assign the trunk to ring the hunt group containing the common bell. Common bell control can be used with station hunt groups, individual stations and Universal Answer.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 NOVEMBER 1997 7.7 REMOTE PROGRAMMING To remotely program a system, connect a customer-provided modem to a serial interface connector on a MISC card (see Figure 7–5). Use an RS232C cable as shown in Figure 7–8. When the modem needs to be more then 15 feet away from the KSU, use shielded computer cable. Attach a male DB9 connector to the MISC end and then attach one that matches the requirements of the modem to the other end.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR 44 Y-BR TERM CIRCUIT FUNCTION MOH 1 - 37 1 19 BR-Y 38 MOH 1 + 45 Y-SL 39 PAGE TIP 20 SL-Y 40 PAGE RING 46 V-BL 41 ZONE 1 A 21 BL-V 42 ZONE 1 B 47 V-O 43 ZONE 2 A 22 O-V 44 ZONE 2 B 48 V-G 45 ZONE 3 A 23 G-V 46 ZONE 3 B 49 V-BR 47 ZONE 4 A 24 BR-V 48 ZONE 4 B 50 V-SL 49 SL-V 50 25 CUSTOMER-PROVID
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 600 PIN COLOR TERM CIRCUIT 44 Y-BR 37 MOH 1 - 19 BR-Y 38 MOH 1 + 45 Y-SL 39 20 SL-Y 40 46 V-BL 41 21 BL-V 42 ZONE 1 B 47 V-O 43 ZONE 2 A 22 O-V 44 ZONE 2 B 48 V-G 45 ZONE 3 A 23 G-V 46 ZONE 3 B 49 V-BR 47 ZONE 4 A 24 BR-V 48 ZONE 4 B 50 V-SL 49 MOH 2 - 25 SL-V 50 MOH 2 + 1 FUNCTION PAGE TIP CUSTOMER-P
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 CUSTOMER-PROVIDED PAGING AMPLIFIER 600 PIN COLOR 44 Y-BR 37 MOH 1- 19 BR-Y 38 MOH 1+ 45 Y-SL 39 TERM CIRCUIT FUNCTION IN OUT PAGE TIP 1 20 SL-Y 40 PAGE RING 46 V-BL 41 ZONE 1A 21 BL-V 42 47 V-O 43 22 O-V 44 48 V-G 45 2 ZONE 5 ZONE 1B ZONE 2A 3 ZONE 6 ZONE 2B ZONE 3A ZONE 7 4 23 G-V 46 ZONE 3B 49 V-BR 47 ZONE 4
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR 42 Y-0 TERM CIRCUIT 17 O-Y 34 43 Y-G 35 18 FUNCTION N. O. 33 1 COMMON N. C.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents PORT 2 TNR1 P7 U6 C10 BAR CODE U5 Y2 C12 U4 U7 T1 C14 C15 C17 U1 Y1 TNR4 U8 TNR3 TNR2 U3 U2 P1 P2 PORT 1 DCS COMPACT (MISC) MISC CARD FIGURE 7– 5
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 JUNE 2001 HOME PAGE Table of Contents MISC CARD PRINTER TXD 2 2 RXD 3 3 GND 7 7 DTR 5 20 PIN CONNECTIONS FOR MISC CARD TO PRINTER FIGURE 7– 6 MISC CARD PC COM 1 TXD 2 2 RXD 3 3 GND 7 5 DTR 5 4 9 PIN PIN CONNECTIONS FOR MISC CARD TO PERSONAL COMPUTER MISC CARD COM 2 3 OR 2 7 20 25 PIN FIGURE 7– 7 MODEM TXD 2 2 TXD RXD 3 3 RXD GND 7 7 GND PIN CONNECTIONS FOR MISC CARD TO MODEM FIGURE 7– 8
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents SCR1 SCR5 EXPANSION SLOT 3 EXPANSION SLOT 2 EXPANSION SLOT 1 P2 SCR2 SCR3 SCR4 PFT JACK 4 COP SLOT PSU RAM PACK SLOT 2 SLI SLOT MISC SLOT LOCATION OF PFT JACK FIGURE 7– 9
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 NOVEMBER 1997 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY SLI OR 8SLI CARD PIN COLOR TERM 26 W-BL 1 1 BL-W 2 27 W-O 3 2 O-W W-GN 4 28 3 GN-W 6 29 W-BR 7 4 BR-W 8 30 W-S 9 CIRCUIT 1 FUNCTION SLT TIP SLT RING 2 SLT TIP SLT RING 5 3 S-W 10 31 R-BL 11 6 BL-R 12 32 R-O 13 7 O-R 14 33 R-GR 15 8 GR-R 16 34 R-BR 17 9 BR-R 18 35 R-S 19 10 S-R 20 36 BK-BL 21 11 B
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 DECEMBER 1994 HOME PAGE Table of Contents 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 PIN COLOR 40 BK-SL TERM CIRCUIT 29 FUNCTION SLT TIP 1 15 SL-BK 30 41 Y-BL 31 16 BL-Y 32 SLT RING SLT TIP 2 SLT RING ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG R G BK Y W BL 1 2 3 4 5 6 CONNECT TO ANY CIRCUIT ON 2 SLI CARD.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 NOVEMBER 1997 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY DLI CARD PIN COLOR TERM 26 W-BL 1 1 BL-W 2 27 W-O 3 2 4 28 O-W W-GN 3 GN-W 6 29 W-BR 7 4 BR-W 8 30 W-S 9 CIRCUIT 1 FUNCTION DLI TIP DLI RING 2 DLI TIP DLI RING 5 3 S-W 10 31 R-BL 11 DLI TIP R G BK Y W BL DLI RING DLI TIP 4 5 ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG DLI RING 6 BL-R 12 32 R-O 13 7 O-R 14 33 R-GR 15 8 GR-R
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 NOVEMBER 1997 HOME PAGE Table of Contents CTM PC COM 1 TXD 2 2 RXD 3 3 GND 5 5 7 9 PIN 25 PIN PIN CONNECTIONS FOR CTM TO PERSONAL COMPUTER 72" 3 7 5 5 RS232 Female DB9 Connector DCS CTM CABLE 2 2 3 3 OR TO CTM 2 2 3 FIGURE 7– 13 TO PERSONAL COMPUTER COM2 RS232 Female DB25 Connector COM 2 RS232 Male DB9 Connector 8" TO PERSONAL COMPUTER COM1 FIGURE 7– 14
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 7 JUNE 2001 HOME PAGE Table of Contents Start Perform Physical Installation and Software Setup (Location and Driver in Control Panel - Telephony ICON) and load DCS TAPI Service Provider. A NO 1. Check CTM connections 2. Change out CTM CTM PWR and DTR LEDs illuminated? YES Run Windows Phone Dialer Application A B NO Is attempt to make outgoing call successful? 1. Check software setup especially COM port selection 2.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 PART 8. INSTALLING KEYSET DAUGHTERBOARDS 8.1 KDB DLI Before performing this procedure, the line cord must be unplugged from the keyset. The base wedge should then be removed, the keyset should be placed face down on a soft surface and the four base retaining screws removed (see Figure 8–1). The base should now be separated from the keyset and the keyset top half set aside.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 HOME PAGE Table of Contents HANDSET TEL RETAINING SCREWS RETAINING SCREWS KEYSET BASE FIGURE 8– 1
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 HOME PAGE Table of Contents MOUNTING SCREWS RIBBON CABLE CONNECTOR INSTALLING KDB DLI DAUGHTERBOARD FIGURE 8– 2
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 HOME PAGE Table of Contents KEYSET DAUGHTERBOARD OUTPUT JACK HANDSET TEL OUTPUT JACK FIGURE 8– 3
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 HOME PAGE Table of Contents HOOK P1 P2 P7 SP MIC PLUG RIBBON CABLE FROM DAUGHTERBOARD INTO RIBBON CABLE CONNECTOR P7 CONNECTING KEYSET DAUGHTERBOARD TO KEYSET PCB FIGURE 8– 4
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 HOME PAGE Table of Contents RIBBON CABLE CONNECTOR MOUNTING SCREWS INSTALLING KDB SLI DAUGHTERBOARD FIGURE 8– 5
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 HOME PAGE Table of Contents LINE CORD SCROLL VOL OUTPUT JACK 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WXY SPK HOLD TRSF TEL 0OPER HANDSET ANS/ RLS SECOND KEYSET FIRST KEYSET CONNECTING A KEYSET TO A KDB-DLI FIGURE 8– 6 LINE CORD OUTPUT JACK TEL HANDSET SINGLE LINE TELEPHONE FIRST KEYSET CONNECTING A SINGLE LINE TELEPHONE TO A KDB-SLI FIGURE 8– 7
MDF CROSS-CONNECT SECOND PAIR TO DIFFERENT STATION CABLE MULTI-PAIR STATION CABLE G G G R R R Y Y Y BK BK BK BL W BL W BL W 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 VOL SPK ANS/ RLS TRSF HOLD 6 MNO 0OPER 9 WXY 3 DEF 5 JKL 8 TUV 2 ABC 4 GHI 7 PRS 1 SCROLL CONNECT TO KEYSET OR SLT DEPENDING ON KDB TYPE TEL HANDSET CONNECTING A STATION DEVICE TO A KDB VIA THE MAIN DISTRIBUTION FRAME 1 PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 8 DECEMBER 1994 FIGURE 8– 8 HOME PAGE Table of Con
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 9 DECEMBER 1994 PART 9. CHANGING SOFTWARE 9.1 ACCESSING THE EPROMS In order to easily replace the system software, it may be necessary to partially disassemble the KSU. This procedure should be performed in the following sequence while referring to Figure 9–1. 1. Check the battery switch on the RAM pack and make sure it is on.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 9 DECEMBER 1994 HOME PAGE Table of Contents HOLDING SCREW LOCATIONS LOCATION OF HOLDING SCREWS PSU FIGURE 9–1
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 9 DECEMBER 1994 HOME PAGE Table of Contents 4 COP SLOT PSU RAM PACK SLOT U3 ODD-1 U44 ODD-2 U4 EVEN-1 U45 EVEN-2 LOCATION OF EPROMS FIGURE 9–2 9–3
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 10 JUNE 1995 PART 10. INSTALLING CALLER ID 10.1 GENERAL INFORMATION In order to install Caller ID on a DCS COMPACT, you must have the following pieces of DCS COMPACT equipment available: z z z A RAM 2 card to hold the Caller ID database A MISC 2 card to decode the incoming Caller ID data A set of four EPROMs containing the Caller ID version of system software A personal computer with the latest version of CPCMMC for the DCS COMPACT is recommended.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 10 JUNE 1995 z MMC 725 SMDR OPTIONS The ability to print Caller ID data and abandoned calls has been added to this MMC. z MMC 119 CID DISPLAY This MMC is used by the end user to determine which piece of Caller ID data is displayed when a call rings at the user’s station. z MMC 501 SYSTEM TIMERS This MMC has two new timers related to Caller ID. The only timer that may need adjustment is the CID DISPLAY TIME.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 10 JUNE 1995 to make the system recognize that the card has been changed. A second download of the customer database should be made at this point. This second download is the database that will be uploaded back into the system when the RAM 2 is installed. The third step is upgrading the system software to the Caller ID version as described in Part 9 of the Installation Section.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 11 JUNE 1995 PART 11. ADDING CARDS TO AN EXISTING SYSTEM 11.1 ADDING A MISC CARD 1. 2. 3. 4. 5. 6. Check the battery switch on the RAM pack and make sure it is ON. Turn off power to the system and unplug the power cord. Insert the MISC card into the slot labeled MISC. Restore power to the system. Open system programming and use MMC 806 to initialize the card. Use MMC 724 to assign directory numbers to the ports on the card.
PROSTAR DCS COMPACT TECHNICAL MANUAL 3. 4. 5. 6. INSTALLATION PART 11 JUNE 1995 Insert the 2 X 4 card into an empty slot on the expansion kit. Restore power to the system. Open system programming and use MMC 806 to initialize the card. Use MMC 724 to assign directory numbers to the ports on the card. The port numbers and recommended directory numbers are listed in the table below.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 12 NOVEMBER 1997 PART 12. UPGRADING A SYSTEM TO RELEASE 2 12.1 INSTALLING ON A SYSTEM WITH A MISC CARD The first step in upgrading an existing system that already has a MISC card installed in it is using Release 1 CPCMMC to produce a backup copy of the customer database. Please see Part 5–1 of the CPCMMC Section of this manual for procedures on accomplishing this.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 13 NOVEMBER 2000 PART 13. INSTALLING A SVMi-4 CARD 13.1 SYSTEM SIZE WITH A SVMi-4 INSTALLED The DCS Compact system can support 32 station devices in a fully expanded system. For the purpose of assigning system resources the SVMi-4 card consumes the equivalent system capacity of 4 keysets. This means that when a SVMi-4 card is installed in the Compact the system can now support a maximum of 28 station devices.
PROSTAR DCS COMPACT TECHNICAL MANUAL INSTALLATION PART 13 NOVEMBER 2000 HOME PAGE Table of Contents U32 Upgrade Key Socket U34 Z2 U33 U36 J5 U41 U14 U15 J1 U1 BAR CODE SIO Port U29 U28 U19 U23 U9 U8 S1 U30 J4 Reset Button U27 U25 U10 U26 U21 U24 Compact Flash Socket SVMi-4 CARD FIGURE 13– 1