INSTALLATION07
Choosing the installation location
Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Where possible keep out of sunlight and rain

Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong enough to hold the product weight
Where there is no risk of ammable gas leakage
When installing the unit at a high place be sure to x the unit legs
3 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
Install the unit horizontally
Place where drained water does not become any problem.
Place with no plants (especially climbing plants) and where small animal can not access.
Outdoor unit should not be place higher than 2.4 m or directly under eaves for accessibility for service and OH&S reasons.
• Avoidthefollowingplacestopreventmalfunctionoftheunit
- Where there is machine oil - Salty environment such as seaside areas
- Where sulde gas exists - Other special atmosphere areas
Model
Pipe Length Pipe Height
Minimum Maximum Maximum
✴✴12✴✴
✴✴18✴✴
3 15 7
✴✴24✴✴ 3 20 8
125 mm or
more
100 mm or more
125 mm
or more
'L'metersmaximumtotalpipe
length
Wrap the refrigerant pipes and the drain hose
with the absorbent pad and vinyl tape. Refer to
page 51 for further details.
You can select the direction of
draining (left or right).
'H'metersmaximumtotal
pipe height
The appearance of the unit may be dierent from the diagram depending on the model.
Makeatleastoneround:Itwillhelpreducenoiseandvibration.
'L'masmaximumpipelength
and 3 m as minimum pipe length.
(It will reduce noise and vibration)