AR✴✴JRFN✴✴ AR✴✴FSSSBWK Series Series AR✴✴JRFS✴✴ AR✴✴FSSSCUR Series Series AR✴✴JQFN✴✴ Series AR✴✴JQFS✴✴ Series Air Conditioner user & installation manual This manual is made with 100% recycled paper. This manual is made with 100% recycled paper. imagine the possibilities Thank Thank you you for for purchasing purchasing this this Samsung Samsung product. product. To receive more complete service, please register your product at www.samsung.com/register MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.
Features of your new air conditioner 2-step cooling 2-step cooling function will quickly cool the room to reach the set temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing.
Contents Preparation Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Checking before use . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.
FOR INSTALLATION 01 Preparation Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. This may result in electric shock or fire. Never install the outdoor unit in a location such as on a high external wall where it could fall.
Safety precautions FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. Failing to do so may result in electric shock or fire. FOR USING WARNING If the appliance is flooded, please contact your nearest service center. Failing to do so may result in electric shock or fire.
FOR USING 01 Preparation Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating. Take special care that children do not injure themselves by inserting their fingers into the product. Do not touch the air flow blade with your hands or fingers during the heating operation. This may result in electric shock or burns. Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner.
Safety precautions FOR USING CAUTION Do not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances) Check that the installation frame of the outdoor unit is not broken at least once a year. Failing to do so may result in injury, death or property damage. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.
FOR CLEANING 01 Preparation This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. WARNING Do not clean the appliance by spraying water directly onto it.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.
Technical Specifications MODEL AR12JRFNBWK/MG AR18JRFNBWK/MG AR24JRFNBWK/MG AR18JRFNBGM/MG AR24JRFNBGM/MG AR18JRFSBWK/MG CLIMATES CLASS COOLING T3 T1 T3 T1 T3 12000 Btu/h 10200 Btu/h 18000 Btu/h 15500 Btu/h 22000 Btu/h 18000 Btu/h HEATING (H1) - - RATED VOLTAGE & FREQUENCY RATED CURRENT - 230 V~ 60 Hz COOLING 4.5 A 5.5 A HEATING (H1) 6.8 A 8.2 A - 8.5 A 9.5 A - - COOLING 1010 W 1230 W 1540 W 1850 W 1910 W HEATING (H1) - - - - - - EER / COP COOLING 11.90 8.
Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model. Main parts Room temperature sensor Air filter Air flow blade (up and down) Air intake Air flow blade (left and right) Display Operation indicator Timer/Auto clean indicator Power button/ Remote controller receiver Single user indicator English-12 MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display.
Checking the remote controller Remote controller display Transmit indicator Operation mode indicator Low battery indicator Set temperature/ Time (for Timer option) indicator Fan speed indicator good'sleep indicator Vertical air swing indicator Options indicator Settings indicator Heat mode can be selected ARJQ Series. As to ARJR Series, don’t operate the air conditioner when the remote controller is set to Heat mode. • Make sure that the water does not get to the remote controller.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto Cool In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season. • If current outside temperature is much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.
Basic function Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat (ARJQ). Press the button to set the desired fan speed. Auto Cool Dry Fan Heat (ARJQ) Press the (Auto) (Auto), (Low), (Med), (High), (Low), (Med), (High), (Turbo) (Auto), (Low), (Med), (High), (Turbo) (Auto) (Turbo) button to adjust the temperature.
Adjusting the air flow direction Air flow can be directed to your desired position. Vertical air flow Press the button to make air flow blades vertically. ffTo keep the air flow direction in a constant direction, press the button again. The air flow blade(s) will stop the movement. ffIf you adjust the vertical air flow blade manually, it may not close completely when you turn off the air conditioner. 02 basic function This function will allow you to adjust the air flow direction vertically.
Setting the On/Off timer Setting the On timer When the air conditioner is off; 1. Press the Timer button. button until (On) indicator starts to blink. 2. Press the 3. Press the SET button to set the On timer. -- (On) indicator will keep blinking and you can set the time. 4. Press the button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~24 hours. -- Time can be set from minimum 30 minutes to maximum 24 hours. 5.
Setting the On/Off timer Setting the Off timer When the air conditioner is on; Cancel ffPress the button to make the set time to display as and press the SET button. ffPress the Power ( ) button. 03 TIMER 1. Press the Timer button. button until (Off) indicator starts to blink. 2. Press the 3. Press the SET button to set the Off timer. -- (Off) indicator will keep blinking and you can set the time. button to set the time. 4. Press the -- You can set the time in half hour unit from 30 minutes (0.
mode For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage. When the air conditioner is operating in Cool/Heat (ARJQ) mode; 1. Press the Timer button. button until ( ) indicator starts to blink. 2. Press the 3. Press the SET button to set the mode. -- ( ) indicator will keep blinking and you can set the time. 4. Press the button to set the time. -- You can set the time in half hour unit from 30 minutes (0.
2-Step cooling function 2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature. 1. Press the Options button. button until (2-Step) indicator starts to blink. 2. Press the 3. Press the SET button to set the 2-Step Cooling function.
Using the Fast function You can set the Fast function to provide fast and powerful cooling. When the air conditioner is operating in Cool mode; 1. Press the Options button. button until (Fast) indicator starts to blink. 2. Press the 3. Press the SET button to set the Fast function. -- (Fast) will blink first, then remain on the display as (Fast) and Fast function will begin. Cancel ffPress the Options button again to make the (Fast) indicator blink and press the SET button.
Using the Single User function This function will reduce the energy usage while the air conditioner is operating in Cool mode. When the air conditioner is operating in Cool mode; 04 OPTIONS Press the Single user button on the remote controller. ff" " appears on the remote controller display for few seconds and disappears. ffSingle user indicator and air swing indicator appear automatically on the remote controller display. The air flow blades move up and down.
Using the Auto Clean function Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with clean air. When the air conditioner is operating; 1. Press the Settings button. 2. Press the button until (Clean) indicator starts to blink. 3. Press the SET button to set the Auto clean function. -- (Clean) indicator will be displayed on the remote controller display and Timer ( ) indicator will turn on the indoor unit display.
Cleaning the air conditioner CAUTION • Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner. 06 OTHERS Cleaning the indoor unit Wipe the surface of the unit with a slightly damp micro fiber cloth when needed. • C ontact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled. • Since the panel of the indoor unit is easily scratched, you should use a micro fiber cloth to clean the panel.
Cleaning the air conditioner Removing the Air filter Air filter There is a hole on the bottom right side of the filter. Put your finger in that hole to get a grip on the filter and slightly push it up to release the hooks from the bottom side. Then, pull it down to remove the filter from the main body. Cleaning the air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Remove the air filter from the main body.
Cleaning the air conditioner Reassembling the Air filter Air filter 06 OTHERS 1. Put the filter on the main body and insert the hooks which are in the top of the Air filter into the main body. ➀ 2. There’s one hook in both side of the filter, press the surface of the Air filter softly and get the hooks into the main body. ➁ 3. Press the bottom of the filter lightly to securely fix the main body. ➂ ➃ ➄ English-27 MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours.
Troubleshooting The air conditioner • Check power status and then operate the air conditioner again. does not work at all. • P lug in or switch on the circuit breaker and then operate the air conditioner again. • Ensure Isolator is switch on. • Check if you have set the Off Timer. Operate the air conditioner again by pressing the Power button. The temperature adjustment is not working. • C heck if you have selected Fan/Fast mode.
Troubleshooting PROBLEM SOLUTION Fan speed adjustment is not working. mode. In • C heck if you have selected Auto/Dry/Fast/ these mode, fan speed is set to Auto and you cannot adjust the fan speed. Remote controller is • Check if your batteries are depleted. not working. • Make sure nothing is blocking your remote controller sensor. • Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves.
Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment. • Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components. • Verify that installation and testing operations are performed by qualified personnel.
Installing the unit IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.
Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3 m or more away from the TV or radio (to prev
Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake Air outlet Air intake Air outlet , Air flow direction.
Choosing the installation location (Unit : mm) 500 or more 300 or more 500 or more 600 or more 1500 or more 600 or more When the upper part of the outdoor unit and the air outlet is opposite the wall 300 or more When front and rear side of the outdoor unit is towards the wall 1500 or more 600 or more 3000 or more 3000 or more 07 Installation 300 or more When the walls are blocking front and the rear side of the outdoor units 200 or more • I f installation is done in inappropriate
• T he flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • The wire assembly cable is optional. If it is not supplied, use the standard cable. • The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below. Optional accessories The following connection accessories are optional.
Fixing the installation plate Screw(M4x10) Screw 07 Installation 1. Disassemble the cover panel as described in page 38~39. 2. Remove the Hanger plate from the indoor unit. (1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit. (2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it. (3) Pull the installation plate to release it completely from the indoor unit. 3.
Disassembling/Assembling the Cover panel for indoor unit installation Please scan this QR code for detail video of indoor unit installation. In order to install the indoor unit, you must disassemble the cover panel first. Please proceed following instructions to disassemble and assemble the cover panel. Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel. Please follow the following instructions.
Disassembling/Assembling the Cover panel for indoor unit installation ffRemoving the hooks on the side ffRemoving the hooks on the central part ① 07 Installation ② ① Caution (fragile) -- Gently press the both side of the cover panel inwards (①) and release the hooks on both sides(②). Caution (fragile) -- Use both hands -- Release each hook by pushing it up at an angle.
Connecting the assembly cable Cable specification Model Power cable Interconnection cable Type GL 12 3G x 1.0 mm², H05VV-F 4G x 1.0 mm², H07RN-F 20 A 18 3G x 2.5 mm², H05VV-F 4G x 1.5 mm², H07RN-F 25 A 24 3G x 2.5 mm², H05VV-F 4G x 2.5 mm², H07RN-F 25 A • C onnect the power cable to the auxiliary circuit breaker.
Connecting the assembly cable When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections. 1. Extend the assembly cable if necessary. • D o not connect two or more different cables to extend the length. It may cause fire.
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flows out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 07 Installation 1. Unscrew the caps at the end of each pipe. All inert gas exhausts from the indoor unit.
Cutting or extending the pipe 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Correct Inclined Damaged Surface Cracked Uneven Thickness 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Torque Flare nut Outer Diameter N•m kgf•cm ø6.35 mm 14~18 140~180 ø9.52 mm 34~42 350~430 ø12.70 mm 49~61 500~620 Indoor outlet pipe Connecting pipe ø15.
Installing and connecting the drain hose of the indoor unit Ditch Keep a clearance of at least Do not place the end of the 5 cm between the end of the drain hose in a hollow. drain hose and the ground. 1) Correct connection Drain hose 07 Installation 5cm less After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well drained.
Installing and connecting the drain hose of the indoor unit 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. 8. Using natural drainage method, check the drainage is normal. Drain hose Extension drain hose • T he hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 51 for further details.
Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following. • T o avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit. Drain plug Drain hole 07 Installation 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. Bottom surface of outdoor unit 2.
Evacuating the connected pipes 1. Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut. Outdoor unit Indoor unit Gas pipe side 2. Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque. • Excessive torque can be cause of gas leakage. Liquid pipe side Torque N•m kgf•cm 14~18 140~180 34~42 350~430 49~61 500~620 68~82 690~830 Outer Diameter 3.
Evacuating the connected pipes Important information regulation regarding the refrigerant used 1. Please fill in with indelible ink, Refrigerant type R-410A GWP value 1975 07 Installation This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. GWP=Global Warming Potential Contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Performing the gas leak tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). A D C B Test part for outdoor unit Test part for indoor unit Tightening torque for body cap (Refer to the table) Before inspecting the leakage, use a torque wrench to close the cap for the service valve.
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. Insulation 07 Installation 1. To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. Pipes 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3.
Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions. Execute Smart Install mode after installation. 1. Check the installation status of the air conditioner. 1) Check the power supply, service valve (if it's open), power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension. 2) Status of the indicator after supplying the power : Standby status 2.
2) Smart Install mode in progress • 88 Display : Progress will be displayed in 0~99. • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink. (This will be repeated.) TYPE 88 Display LED Display ❋❋ Display may be different depending on the model. 07 Installation LED1 LED2 LED3 Indoor unit indicator 3. Smart Install mode will end. 1) Smart Install mode will take approximately 7~13 minutes. (Actual time may be different depending on the model.
Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1.
Packing and unpacking guide Indoor unit Packing the unit as below procedure Put the indoor unit onto the packing case. Assemble cushion-both side of indoor unit. (Left and Right) Seal the packing case. 1. 2. 3. Unpacking the unit as below procedure Open the packing case. Take out the both side of cushion(Left and Right). Move the set from the packing case. 07 Installation 1. 2. 3. Outdoor unit 1. 2. 3. 4. Packing the unit as below procedure Put the outdoor unit onto the cushion-bottom.
How to connect your extended power cables I tems to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Spec Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already.
English-57 MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.
QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT IRAN 021-8255 www.samsung.com/iran/support SAUDI ARABIA 920021230 www.samsung.com/sa/support www.samsung.com/sa_en/support U.A.E 800-SAMSUNG (800 - 726 7864) www.samsung.com/ae/support www.samsung.com/ae_ar/support QATAR 800-CALL (800-2255) www.samsung.com/ae/support www.samsung.com/ae_ar/support BAHRAIN 8000-GSAM (8000-4726) www.samsung.com/ae/support www.samsung.com/ae_ar/support OMAN 800-SAMSUNG (800 - 726 7864) www.samsung.