Service manual

Rev. 2.00
- 97 -
SRP-275
5-4 SRP-275 Whole unit Sub-assembly
5-4-1 Cover base assy
Part name Assembly procedure
Cover base
Frame paper control
PMO-roller paper/end -3ea.
Switch-paper near end ass’y
(Sub-assembly 5-4-2)
Screw-tapping (M2×5) -2ea.
PCB-connector sub ass’y
Screw-taptite (M3×6) -4ea.
FPC-16pin
1. Attach Frame paper control to Cover base.
2. Insert three PMO-roller paper/end to Cover base.
3. Tighten Switch-paper near end ass’y to Cover base with
two Screw-tapping (M2×5).
4. Tighten PCB-connector sub ass’y to Cover base with two
Screw-taptite (M3×6).
5. Insert FPC-16pin in PCB-connector sub ass’y.
6. Insert the connector of Switch-paper near end ass’y in
connector of PCB-connector sub ass’y.
1
7
7
2
2
2
2
4
5
5
6
7
7
7