Product Features The door can be opened with a card. The door can be opened with the card contained in the product package. ® SHS-7020 model accept MIFARE 13.56MHz ISO14443A type card. SHS-7120 is compatible with most HID Proximity 125KHz cards ® ® ® (ProxCard Ⅱ, ISOProx Ⅱ, DuoProx Ⅱ, Smart ISOProxⅡ™, Smart ® ® DuoProx Ⅱ, iCLASS Prox 26bit up to 37bit). The door can be opened with the password. A password can be registered and used to open the door without the key.
Table of Contents Product Features 1 Safety Cautions 4 Before Using the Product 7 Product Components................................................................... 7 Outdoor Unit Parts ...................................................................... 9 Indoor Unit Parts .......................................................................10 Replacing the Battery ................................................................ 11 Using the Emergency Battery ..................................
Additional Functions 27 Setting up and Releasing the Passage Mode (Code 70/71) ..............27 Setting up Current Time .............................................................27 Setting up and Releasing the Random Security Function (Code 90~95)...........................................................................28 Setting up and Releasing the Sound (Code 00~03)........................29 Warning Sound/Alarm Sound ..................................................... 30 PC Connection............
Safety Cautions This section contains important information to ensure the user’s safety and prevent potential damage to property. Please read this section carefully and use the product accordingly. Warning, Caution and Note Explained: Warning Information given under this heading is information the user must be aware of to prevent physical harm. Caution Information given under this heading is information the user must be aware of to prevent service problems or system damage.
Cautions during Installation The user shall not install or repair the product without authorization. The manufacturer does not assume the responsibility for damage to the product resulting from attempts to the user to install or repair it without authorization. Do not install the product in the place where the gap between the door and the frame is 5mm or more. If the gap is too wide, the product may not function properly. Cautions during Operation.
Cautions during Installationnce Please do not hang on the product or pull it. It can damage the product or cause its malfunction. Cautions during Repair or Maintenance Be sure to correctly match the poles (+/-) when installing the batteries. Install the batteries with the correct poles (+/-). Replace all batteries immediately after they run out of power, and never mix new batteries with used ones. Improperly installed batteries can cause rupture or battery fluid leakage.
Before Using the Product Product Components Outdoor Unit Cylinder Key Cylinder 'AA' Batteries (LR6) Indoor Unit Rose Emergency Key Card Latch Bolt Cylinder Retainer Access Mgmt.
Allen - Wrench Indoor Unit Fastening Bolts Strike and Latch Bolts Indoor/Outdoor Unit Fastening Bolts The product components to be used may vary depending on the installation environment.
Outdoor Unit Parts Keypad On Keypad Keypad Off [Wake Up] Button Card Reader USB Cable Connector Outdoor Handle Emergency Key Hole External Power Contact No Name Function Description 1 Keypad The code is entered in the program mode, or the password is input. 2 [Wake Up] Button The keypad is lighted so that the password can be entered or input of card can be read. It is pressed to terminate the program mode. 3 Card Reader Card reader is the unit that reads the user card to open the door.
Indoor Unit Parts Battery Cover [Register] Button Indoor Handle No. 10 Name Description 1 Battery Cover It is the cover that protects batteries and the [Register] button. 2 [Register] Button The button is used to run in program mode or to release the warning sound. 3 Indoor Handle The door can be opened while the indoor handle is turned down.
Replacing the Battery 1. Battery Replacement Alarm Generation “For Elise” It is time to replace the battery if the low voltage warning sound is activated before the door is opened with a password or a card. Battery Use The actual life of the batteries can differ from the manufacturer, date of manufacturing and operating environment. Assuming 5 AA alkaline 1.5V batteries used 10 times a day, it should last at least a year. 2.
Using the Emergency Battery 1. When Lock Fails to Operate Due to Discharged AA Batteries If the batteries are not replaced after their replacement time comes, they will be completely discharged and the doorlock will not operate. or Card Recognition Password Entry The door is not opened. 2. Using the 9V Battery Buy an emergency 9V battery at the nearest store. As the alkaline batteries offer longer life, they are recommended than the manganese batteries or rechargeable ones. 3.
Using the Emergency Key The emergency key is used when the unit stops operating due to the discharged batteries or other circuit problems. Insert the emergency key into the emergency key hole on the outdoor handle and rotates it left and right to unlock the door. - Make sure to keep or carry one or more emergency key. - When you’ve lost the emergency key, contact the service center to exchange the key cylinder wholly. (The exchange of the key cylinder is a paid service.
Basic Functions This section describes the ways to initialize the information registered in the doorlock, to register the password and card data, and to open or close the door. Opening the Door from Outside with a Password or a Card 1. Pressing the [Wake Up] Button The keypad is lighted when the [Wake Up] button is pressed. 2. Entering the Password or Contacting the Card Successful: "Too~~t” Failed: "Toot~" or Press the [¿] button after entering the password or place the card.
3. Entering the Password (When the random security function is activated) Successful: "Too~~t” Failed: "Toot~" Touch all randomly displayed numbers and enter the password before pressing the [¿] button. - Please refer to the section for ‘Random Security Function Setup and Release’ (page 30). Opening the Door from Inside Turning the Doorlock Handle Too~~t Turn down the doorlock handle on the indoor unit.
Program Function This section describes how to initialize the user data registered in the doorlock and how to start the program mode. It also describes how to designate users into a group to register the group’s password and card data as a way of easy management. User Group Management SHS-7020/7120 allows the registration of password and card data for each user group. Up to 250 user codes can be grouped. Either a password or card data can be registered for each user.
Functional Setup or Release Summary Code Function Setup or Release (Follow the steps in the exact sequence.) Ref. Page - Press the [Initialization] button on the indoor unit. Initialization Input the current master password or '1470852369'. (Complete removal Press the [¿] button. of all passwords and card data) ※ The password is reset to ‘1234’ after initialization. - Program Mode Execution Press the [Register] button on the indoor unit.
Program Mode The user data can be registered, changed or deleted by entering the code in the doorlock after making it the Program Mode. 1. Pressing the [Register] Button (from inside) Toot Open the battery cover of the indoor unit and press the [Register] button. 2. Entering the Master Password (from outside) Successful: "Too~~t” Failed: "Toot~~" Enter the current master password or administrator password. Then press the [¿] button or place the administrator card.
Changing the Master Password (Code 10) A master password can be 4~12 digits. Attention must be paid to security since there is no control in doorlock configuration as well as user data registration and removal must be after authenticating the master password. Please register a new master password after initializing the doorlock. 1. Entering the Code in the Program Mode Toot, Toot When 1, 2 and 3 flash after the program mode is operated, enter the code 10 and press the [¿] button. 2.
Registering the User Password (Code 20) The user password can be 4~12 digits. Up to 250 codes can be registered, including the card registration. 1. Entering the Code in the Program Mode Toot, toot When the LED numbers 1, 2 and 3 flash after the program mode is run, press the code 20 and then the [¿] button. 2. Entering the User Code Toot, toot When the LED numbers 4, 5 and 6 flash, press the user code (1~250) and then the [¿] button.
4. Registering an Additional Password (optional) Toot, toot When the LED numbers 4, 5 and 6 flash after the password is saved, repeat the steps 2 and 3 within 10 seconds to register the additional passwords. (The program mode is automatically terminated when there is no key entry within 10 seconds.) - To terminate the program mode without registering the additional password, press the [Register] button on the indoor unit or the [Wake Up] button on the outdoor unit. 5.
Registering the Temporary Password (Code 30) A temporary password can be registered for one time use. The registered temporary user code and password are deleted after a single use. - A temporary password cannot be in the administrator group. Therefore, the temporary password should be registered in the user code 11 ~ 250. - A temporary password can be used only once. 1.
4. Entering an Additional Temporary Password (optional) When the LED numbers 4, 5 and 6 flash after the password is saved, repeat the steps 2 and 3 within 10 seconds to register the additional passwords. (The program mode is automatically terminated when there is no key entry within 10 seconds.) Registering the User Card (Code 40) Either the card enclosed in the product package or ISO 14443 A Type can be registered. User care up to 250, including the passwords, can be registered. 1.
3. Placing the Card Too~~t, toot, toot When the LED numbers 7, 8 and 9 flash, place the card to the card reader on the outdoor unit. The card is registered after the sound of ‘Too~~t, toot, toot’. - The unit turns into the user code entry standby mode. 4. Registering an Additional Card (optional) Toot, toot When the LED numbers 4, 5 and 6 flash, repeat the steps 2 and 3 within 10 seconds to register the additional cards.
User Code Activation/Deactivation/ Deletion (Code 50~55) It is the function to activate/deactivate/delete the registered user codes individually or in groups. It temporarily allows or disallows the entrance of a particular user or group. 1. Entering the Code in the Program Mode Success: "Too~~t" Failure: "Toot~" When the LED numbers 1, 2 and 3 flash after the program mode is operated, press one of the following codes and then press the [¿] button.
Entrance Control Setup (Code 60~63) The entrance control can be set up or released to the registered user codes individually or in a group. 1. Entering the Code in the program mode Success: "Too~~t" Failure: "Toot~" When the LED numbers 1, 2 and 3 flash after the program mode is run, press one of the following codes and then press the [¿] button.
Additional Functions Setting up and Releasing the Passage Mode (Code 70/71) The Passage function allows free entrance and exit of the people by maintaining the door unlocked. It is a convenient when the free access is needed. Entering the code in the program mode Valid Entry: "Too~~t" Invalid Entry: "Toot~~" When the LED numbers 1, 2 and 3 flash after the program mode is operated, press one of the following codes and then press the [¿] button.
Setting up and Releasing the Random Security Function (Code 90~95) It lights up a series of random numbers on keypad so that the lighted numbers must be all touched before the password is entered. The feature can enhance the doorlock security. Valid Entry: "Too~~t" Invalid Entry: "Toot~" When the LED numbers 1, 2 and 3 flash after the program mode is operated, enter the code 90~95 and then press the [¿] button.
Setting up and Releasing the Sound (Code 00~03) This function allows setting up the sound activated when the keypad is pressed or the door is locked or unlocked. Setting up the sound function Default setting is to activate all sound levels (3 sound level setting). When the LED numbers 1, 2 and 3 flash after the program mode is operated, enter the code 00~03 and then press the [¿] button.
Warning Sound/Alarm Sound Warning Sound Activated (prevention of mischief behavior) It is a function of activating the warning sound and deactivating the unit in case the doorlock is improperly operated from outside. Password and Card Authentication Error Toot~ toot~ (Activated 20 times) or Case of using invalid master password, user password or card for 5 times in a row (A warning sound is activated, and the doorlock becomes deactivated for 3 minutes.
Releasing the Alarm It is the function of activating the emergency alarm when the outdoor unit of the installed doorlock is forcefully separated. Intrusion Detection Operation Toot~, toot~, toot~ If the outdoor unit is forcefully separated, the alarm sound “toot~, toot~, toot~” is continuously activated. Releasing the Intrusion Detection Alarm Sound The alarm sound is released when the micro switch inside the outdoor unit is pressed.
PC Connection Connect the USB cable (A-B Type) to the USB adapter on the outdoor unit and turn the unit into the PC registration mode. In this mode, all user data registered in the doorlock can be downloaded or uploaded. Outdoor unit PC Initialization All registered administrator and user data are deleted, and the unit is reset default setting. - After the doorlock is initialized, register a new master password. 1. Separate the inside doorlock unit and press the [Initialize] button located inside. 2.
Troubleshooting Check the following first if the product does not operate properly. Contact the nearest service center if the problem remains unsolved. Power Problem No power is supplied. Resolution - Check if the batteries are OK or if they are inserted with the poles in the right places. - Check if the batteries are properly inserted or whether they are completely discharged.
Passage Mode Problem The doorlock is not automatically locked. Resolution Reference - Check if the Passage mode is set up. The mode is set if the door is locked when the handle on the outdoor unit is turned without any keypad entry. - The doorlock is improperly installed if it is not automatically locked while the Passage mode is released. Please contact s Digital Doorlock reseller and have it reinstalled.
User Code Registration Table User Code Password (4~12 digits) User Name 35
Product Specification Item Voltage Specifications When using a battery This product accepts 1.5V AA Size battery only(5EA, 7.5V) When using an external power supply This product accepts our genuine accessory, SHT-PS1250X. For more product information, please contact Seoul Commtech. Emergency Power Source 9V Battery (6LF22) (Separately purchased) Operation Method Electronic Control Method (Password entry or card reading) Weight 2.
Product Warranty