SCF-V01 V01 User Manual SCF-V01 User Manual VIA Telecom CBP7.1C 1C CDMA Solution REV 0.1 Samsung Electro-Mechanics 2012-06-18 Summary This datasheet presents the general performance and specifications of SCF-V01 CDMA2000 A 1x Rel.0 and 1X EV-DO Rev.A A Module. © 2012 Samsung Electro-Mechanics. Mechanics. All rights reserved The names of actual companies and products mentioned herein may be the trademarks of their respective owners.
SCF-V01 V01 User Manual Table of Contents 1 GENERAL DESCRIPTION ................................................................................................ .................................... 3 1.1 FUNCTIONAL DESCRIPTION ................................................................................................ ..................................... 3 1.2 FEATURES ................................................................................................ ................................ ...
SCF-V01 V01 User Manual 1 General Description 1.1 Functional Description SCF-V01 is the cellular module for either the CDMA2000 A 1x Rel.0 or 1X EV/DO Rev. Rev A at embedded and wireless M2M applications. It provides all the RF, Processing, Memory, Power Management and software, which is based on the Via Telecom CBP6.x or CBP7.x solution. It supports Cell and PCS bands. 1.2 Features Dual band cellular and PCS voice and data Variant module : CDMA2000 A 1x Rel.0 or 1X EV/DO Rev.
SCF-V01 V01 User Manual 1.4 Block Diagram The following SCF-V01 block diagram highlights the major func functional tional blocks and interfaces. Figure 1-1. SCF-V01 Hardware Block Diagram REV 0.
SCF-V01 V01 User Manual 2 Dimension and Pin Assignments 2.1 Mechanical Dimension Form factor : Standard PCI Express® Express Mini Card Electromechanical Speci Specification (Full-Mini Mini Card) Size : W x L x H (50.95 x 30.0 x 4.75mm) with 1.0mm PCB Weight : 9.8g Figure 2--1. SCF-V01 Mechanical Dimension n (Top View) REV 0.
SCF-V01 V01 User Manual 2.2 Antenna Connection U.FL connector for the Main ain ANT, Diversity ANT, and GPS ANT Figure 2--2. Antenna Connector Mechanical Dimension Attaching ttaching an antenna to the SCF-V01 : Use a Hirose U.FL connector (Part No. : U.FL U.FL-R-SMT, CL No. : 331--0471-0-10) to attach an antenna to a connection point on the SCF SCF-V01. Match coaxial connections between the SCF SCF-V01 and the antenna to 50 Ω.
SCF-V01 V01 User Manual 3 Pin Assignments and Descriptions 3.1 Pin Assignments Pin# 51 49 47 45 43 41 39 37 35 33 31 29 27 25 23 21 19 17 Mini Card Standard Reserved Reserved Reserved Reserved GND +3.3Vaux +3.3Vaux GND GND PETp0 PETn0 GND GND PERp0 PERn0 GND UIM_C4 UIM_C8 15 13 11 9 7 5 3 1 GND REFCLK+ REFCLKGND CLKREQ# COEX2 COEX1 WAKE# SCF-V01 Pin name Pin# Mini Card Standard SCF (JTAG_RST_N) 52 +3.3Vaux (JTAG_TDI) 50 GND (JTAG_TDO) 48 +1.5V (JTAG_TMS) 46 LED_WPAN# GND 44 LED_WLAN# +3.
SCF-V01 V01 User Manual 3.2 Pin Description Pin# Signal Name Type Connection to IC Pin Power Domain Description JTAG Interface 33 JTAG_CLK I CP_TCK (N.C) JTAG Clock 47 JTAG_TDO O CP_TDO (N.C) Data Out 45 JTAG_TMS I CP_TMS (N.C) Mode Selectt 49 JTAG_TDI I CP_TDI (N.C) Data In 51 JTAG_RST_N I CP_TRST_N (N.C) JTAG Reset 31 JTAG_RTCK O CP_RTCK (N.C) JTAG Return Clock UART Interface 23 TXD0 O CP_UART0_OUT (N.C) UART0 data out 25 RXD0 I CP_UART0_IN (N.
SCF-V01 V01 User Manual 34 GND - - Ground 26 GND - - Ground 18 GND - - Ground 4 GND - - Ground Type: I=Input, O=Output, I/O=Bi-directional directional Table 3-2. Pin Descriptions REV 0.
SCF-V01 V01 User Manual 4 Electrical Characteristics 4.1 DC Characteristics Symbol +3.3V Parameter Main input supply from battery to switcher Min Typ. Max Unit -0.5 - +4.8 V Min Typ. Max Unit 3.0 3.3 3 3.6 V Max. Unit Table 4-1. Absolute Maximum Ratings Symbol +3.3 Parameter Main input supply from battery to switcher Table 4-2. Recommended Operating Conditions 4.2 Environmental vironmental Characteristics Symbol Parameter Conditions Min.
SCF-V01 V01 User Manual 4.3 Power Consumption Format RF Band Current @ 3.3V Mode Condition @ Room Temp Idle Mode Typ 160mA Min Tx Power Typ 250mA Typ 670mA Max 750mA Idle Mode Typ 160mA Min Tx Power Typ 220mA Cell Power -25dBm Typ 610mA Tx Power 23.5dBm Max 650mA Idle Mode Typ 200mA Min Tx Power Typ 340mA Typ 900mA Max 940mA Idle Mode Typ 200mA Min Tx Power Typ 330mA Typ 800mA Max 850mA Cell Power -25dBm PCS Tx Max Power 1x_RTT Cellular Tx Power 23.5dBm 23.
SCF-V01 V01 User Manual 5 RF Specifications All measurements are made under nominal supply voltage and room temperature conditions. conditions 5.
SCF-V01 V01 User Manual ITEM Spec LCL Typ UCL Unit 23.0 23.5 5 24.0 dBm 23.0 23.5 5 24.0 dBm -50 dBm -50 dBm Tx Max Power Tx Min Power 0.944 1 0.944 1 -300 300 Hz -150 150 Hz -1 1 us 0.5 % 0.5 % Rho Frequency Error Time Error Rx Sensitivity (Primary / Secondary) Test Condition Cellular Band(824.7MHz,836.52MHz , 848.41MHz) Cal Target : 23.7dBm PCS Band(1851.25MHz , 1880MHz , 1908.75MHz) Cal Target : 23.7dBm Cellular Band(824.7MHz,836.52MHz , 848.41MHz) PCS Band(1851.
SCF-V01 V01 User Manual 6 Label Information 6.1 Module Label The Label contains Model Name, Product Code, FCC ID, MEID and Serial Number. Figure 6-1. Label Information [Information] ① Model : SCF-V01 ② Product Code : CEMF10V01D0101 ③ FCC ID : E2XSCF-V01 ④ MEID : Mobile Equipment Identifier Id ⑤ S/N : Serial Number ⑥ MAIN : Main Antenna connection ⑦ GPS : GPS Antenna connection ⑧ AUX : Diversity Antenna connection 6.1.
SCF-V01 V01 User Manual 7 Safety Information 7.1 Certification FCC ID : E2XSCF-V01 Warning: Exposure to Radio Frequency Radiation The radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact contact during normal operation is minimized.
SCF-V01 V01 User Manual Revision History Revision 0.0 0.1 REV 0.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
SCF-V01 ETS(Engineer Test Software) User Manual REV 0 Steve Heo, Software Application Engineer Software Part WS Development Team Samsung Electro-Mechanics 2012-06-28 Background & Summary This document describes how to use ETS. © 2012 Samsung Electro-Mechanics. All rights reserved The names of actual companies and products mentioned herein may be the trademarks of their respective owners. This document is subject to change without notice.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Table of Contents 1 INTRODUCTION ................................................................................................................. 3 1.1 1.2 2 SETUP AND QUICK START .................................................................................................. 4 2.1 2.2 2.3 2.4 2.5 2.6 2.7 3 VOICE CALL INITIATE .........................................................................................................
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 1 Introduction This document provides high-level functional descriptions of the CBP 5.X CDMA Baseband Processor digital hardware subsystems. 1.1 Acronyms ADC Analog-to-Digital Converter AMPS Advanced Mobile Phone System APB ARM Peripheral Bus CBP5.X CDMA Baseband Processor version 4.1/5.0/5.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Table 1 - External Interface Pin Attributes Type Internal pull-up 2 Internal pull-down pu pd ldrv1 CMOS, low drive strength (1ma) ldrv2 CMOS, low drive strength (2ma) mdrv CMOS, medium drive strength (4ma) CMOS, high drive strength (8ma) hdrv _N z od vanlg 1 Description 1 Indicates an active low signal Tri-state Open-drain Input or output with analog voltage levels Digital VDD to core cells (1.
Samsung Electro-Mechanics Co., Ltd. Proprietary Memory: At least 128 MB of RAM Processor: Pentium II or better REV 0 2.2 Installing and Removing 2.2.1Installing ETS VIA Telecom delivers the installation program, “ETS.exe”, as part of the software release package. VIA Telecom strongly recommends installing ETS in the default directory as the installing shell indicated. The VIA Telecom software releases are typically numbered “rX.Y.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 3. For other items which will meet in installing process, use default setting is fine. Since from now on, all of CBP5.X reference software will use same ETS.exe, you NEED NOT pay additional attention to associate version number between the software release and ETS. 2.2.2Removing ETS Use the standard Windows method to remove (uninstall) software. 1. Go to the Control Panel and select Add or Remove Programs. 2.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 2.3 Running ETS for the First Time Continuing with the example in Section 2.21, start ETS by selecting: Windows Desktop →ETS(Config 0.14.2_vtui2_5x_Selle_P1): Now follow the steps in Section 2.5.1. 2.4 How to Exit 1. From the ETS menu, select File → Exit. See Section 2.5.2 for details on how to save the ETS configuration when exiting. 2.5 Opening and Saving Configuration Files 2.5.1Opening Configuration Files 1.
Samsung Electro-Mechanics Co., Ltd. Proprietary Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 3. After opening default.cfg you should see a screen, which looks similar to the picture below. This screen has all the standard ETS sub-windows which are typically used at VIA Telecom. 2.5.2 Saving Configuration Files 1. If you have used any special ETS commands during your present session which you’d like to use in a future session then you can explicitly save the present configuration by using the ETS Main Menu command: File → Save As 2.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 2.6 ETS Defines File → Defines ETS allows the user to configure the tool for various standard definitions: Note: 1. This defines must be configured correct as the target HW you using. Else it will case some UN-expect error. If you don’t sure which option you should select, call VIA application engineer for help. 2. After you changed the definition, should close and restart ETS to make the effort available. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 2.7 ETS Options File → Options There are some parameters you can modify, the value depend on the CP request. Special for Flash Download Timeout (Sec), we recommend you adjust it longer than the total CP erase time (the lager CP size is, the longer erase time is). 200s is the typically value VIA internal used. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 3 Idle Mode 3.1 RSSI for CDMA CDMA: DSPM → Spy → RFC → DSPM Rfc RxTx Usually this window is opened from loading the “default.cfg” configuration file. Window Entries Print Sys Time Received Power (dBm) Receive PDM Value Rx Gain State Transmit Power (dBm) Transmit PDM Value Tx Gain State RxDAgc Value Definition If checked, the window will be printed onto the main log as a trace: 15:17:28.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 3.3 Registration Message Spy CP → SPY → PS → Call Proc → Engine → ENG_ACCESS_PROC_TR → CP ENG_ACCESS_PROC_TR 1 40 The spy is enabled automatically once the “default.cfg” is loaded. This spy displays all messages from mobile to the base station during idle mode, through access channel. 3.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Print Sys Time Measured AUX ADC Tx Pwr (dBm) Tx Pwr Freq Adj (dBm) Tx Pwr Temp Adj (dBm) Unadj Tx Pwr (dBm) REV 0 Definition If checked, the window will be printed onto the main log as a trace: 10:40:50.1> ETS, Id=CP Spy, SpyId=CP Tx Pwr Detect Measurements, Sys Time=0x823ee47e, Measured AUX ADC=0x04de, Tx Pwr (dBm)=-24.781250, Tx Pwr Freq Adj (dBm)=5.000000, Tx Pwr Temp Adj (dBm)=0.000000, Unadj Tx Pwr (dBm)=19.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 3.6 Pilot Strength Spy CP → Spy → L1D → CP Search Results Active Usually this window is opened from loading the “default.cfg” configuration file. This spy display information of Active PNs involved, candidate PNs that are possible for handoffs, and neighbor PNs that are available for possible handoffs. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Print Sys Time Num Act Num Cand Num Nghbr Stale Pilot PN Phase Strength REV 0 Definition If checked, the window will be printed onto the main log as a trace: 15:36:10.1> ETS, Id=CP Spy, SpyId=CP Search Results Active, Sys Time=0xa249ad32, Num Act=0x01, Num Cand=0x00, Num Nghbr=0x17 , Stale.0=0, Pilot PN.0=54, Phase.0=3457, Strength.0=-4.4224 , Stale.1=1, Pilot PN.1=0, Phase.1=0, Strength.1=-1.#INF , Stale.2=1, Pilot PN.2=0, Phase.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 As an alternative to using the Virtual MMI, calls can be initiated using: CP → PS → UI Command → CP Call Initiate Window Selections Send Tack Otasp Otasp Mode E911 Call Request Mode Service Option Privacy Mode Encoded Digit Mode Number Type Number Plan Number of Digits Digits Definition Send to perform call initiate command. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 4.3 Voice Call Hang Up Similar to section 4.1, there are two ways of achieving this: through Virtual MMI or CP command. Using Virtual MMI, click “End” to terminate a call. Or use CP → PS → UI Command → CP Call Hangup and click “Send” 4.4 Voice Call Configuration 4.4.1Voice Privacy Enable/Disable CP → UI → CP Set Privacy Mode CP → PS → Voice Privacy → CP Voice Privacy Enable (or Disable) 4.4.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 4.4.3 OOS Parameters CP → PS → CP OOS Area Parms Sending this command with the default values shown disables the phone from going out of service (sleep) when the base station is not available for an extended period of time. Window Selections P1-P4 P1 Delay-P4 Delay P1 Cycles-P3 Cycles Definition # of attempts in phase 1-4 sec delay between phase 1-4 attempts number of repeats of N attempts + a delay 4.4.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 4.5 Radio Control 4.5.1 Tx Pwr Detect Measurements Spy Please refer to section 3.4 for detailed description. 4.5.2 RSSI for AMPS and CDMA Please refer to section 3.1 for detailed description. 4.5.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5 Test/Debug Capability 5.1 Basics 5.1.1 Communication Port Configuration USB Port Debug -> Comm -> USB Then the ETS will show the connect port as USB Serial Port Debug → Comm → Serial, to select a COM port for communicate with DUT. CP -> Options, set the Initial Baud Rate as 115200. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.1.2 Loopback Test Debug → Loopback This function used to test the USB/COM communications with CP, DSPM, or DSPV. Calls CP Loopback, DSPM Loopback, and DSPV Loopback. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Number of Messages Number of Timeouts Number of Mismatches Send One Cycle Windowed Fixed Pattern Stop On Error CP DSPM DSPV Message timeout in seconds Disable Printing REV 0 Definition Number of messages sent. Number of failures. Number of differences between what was sent and what was received. Start Loopback test, one click will only sends out one command.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.1.4 Enable Generic Ack Debug → Enable Generic Ack This command controls the display of the acknowledgement to any command sent from ETS to the mobile. If enabled, a response message for each command is returned. A check mark displays next to the command if enabled. 5.2 Test Modes 5.2.1 CP Sleep Control CP → MON → CP Sleep Control This command enables/disables the sleep operation of the CBP5.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 To disable slotted: Set Qualifier to “Off” and click “Send” (Value entry is ignored). To enable slotted: Set Qualifier to “On” and click “Send” (Value entry is ignored). 5.2.3 Pwr Savings Mode Config CP → HWD → Pwr Savings → CP Power Savings Mode Config sets the power savings mode Window Selections Send Tack Ctrl Mode Pwr Saving Mode Voice/Data Mode Options Definition --- Send to perform power savings mode configuration.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Send Tack Ctrl Mode Hw Blks Status Options --Automatic Disable Manual All Blocks On Off REV 0 Definition Send to perform power savings configuration. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Stack values are used – Hw Blks and Status are ignored. Selections made under “Hw Blks” and “Status” are used. This is the recommended setting for manual control.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Below shows the command and respond while the mobile is in traffic: 5.2.7 Diagnostic Parameters (L1D, LMD) 5.2.8 Phone State And Event Control CP → PS →CP Phone State and Event Count Below shows an example when the mobile is on paging: 5.2.9 Get Retrievable Statistics CP → PS →Retrievable Stat → CP Get Retrievable Statistics Window Selections Send Options Definition Send to perform the command, with a response as follow: 16:24:10.
Samsung Electro-Mechanics Co., Ltd. Proprietary , MUX1 REV FCH 7=0x00000000 , MUX1 REV FCH 8=0x0000047e , MUX1 REV FCH 9=0x00000000 , MUX1 REV FCH 10=0x00000000 , MUX1 REV FCH 11=0x00000000 , MUX1 REV FCH 12=0x00000000 , MUX1 REV FCH 13=0x00000000 , MUX1 REV FCH 14=0x00000000 If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Tack Statistics Counter Group REV 0 MUX1_REV_FCH MUX1_FOR_FCH PAG ACC 5.2.10 Timer Enable 5.2.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.2.13 Service Option - SO (TBD) 5.3 RF Interface and Control 5.3.1 CDMA Configuration CP PLL Channel Config RF → CP PSW PLL Channel Config Window Selections Send Tack Ctrl Mode Band Channel Options Definition --- Send to perform the PLL channel configuration. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Stack values are used – selections in Band and Channel are ignored.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Send Tack Calib Mode --NVRAM Default REV 0 Definition Send to perform the Cal Initialize command. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. This loads DBM cache of the DB templates onto the SRAM cache for execution. This loads a default cal file onto flash. Command “CP CAL Init NVRAM” (under RF) is needed in conjunction after the Cal Initialize command.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Send Tack PDM Number REV 0 Options Definition --- Send to perform specified PDM Read. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 This message will select the relevant RF registers based on the Radio Design selected by the “RF Target Option” in Section 2.6 CP RF Tx Reg Read (TBD) RF → RF Registers → CP RF Tx Reg Read This message will select the relevant RF registers based on the Radio Design selected by the “RF Target Option” in Section 2.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Send Tack Mode REV 0 Off On Definition Send to perform CDMA Receiver Control command. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Turn CDMA Receiver OFF. Turn CDMA Receiver ON.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Rx AGC Parameters (L1D) Clear FER 5.3.3 CDMA Transmitter CP CDMA Transmitter Control RF → CDMA → CP CDMA Transmitter Ctrl Window Selections Options Send Tack Mode On Off Definition Send to perform Transmitter control command. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Turn CDMA transmitter ON. Turn CDMA transmitter OFF.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Send Tack Ctrl Mode Automatic Method Manual HW Value dB Gain HW Val Hyst State Power(dBm) Low/Mid/High REV 0 Definition Send to perform Tx AGC control command. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Stack values are used – selections in preceding entries are ignored. Values entered in the preceding entries are used.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Tx Tone Test RF → CP TX Tone Test Window Selections Options Definition Send -- Tack -- Send to transmit a single tone from the transmitter instead of a CDMA spectrum. If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Turn TX tone ON or OFF. Amplitude of tone desired, typical value: 0x0200, in Hex.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Set Busy Idle Status Tx Fixed Freq Tx Calibration 5.3.4AFC DSPM AFC Get Params DSPM AFC Config AFC Cal Parameters (L1D) 5.3.5RF Pin Control CP TXON Control RF → CP TXON Control Window Selections Options Send Tack TxOn [0:4] --Off On Auto Definition Send to enable TXON Control If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Turn TxOn OFF. Turn TxOn ON.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Send Tack RfOn [0:7] Off On Auto REV 0 Definition Send to enable RFON Control If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Turn RfOn OFF. Turn RfOn ON. Allow CBP software to control the RfOn CP TXON Read RF → CP TXON Read Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 CP RXON Read RF → CP RXON Read 5.3.6GPIO Control GPIO Read / GPIO Write CP → MON → GPIO → CP Read GPIO Window Selections Options Send -- Tack -- GPIO Num [0:47] Definition Send to read the relevant GPIO. Caution: This command will set the GPIO to INPUT mode and perform the read. The original state is not preserved so this command should only be performed on GPIOs which are known to be Inputs.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections REV 0 Options Send Tack GPIO Num Action [0:47] SET CLEAR Definition Send to read the relevant GPIO If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Send Tack Control Load Enable NumBits-1 to Shift REV 0 Definition Send to set the Serializer Configuration If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Programs the register SER0_CTRL (listed as SER#_CTRL in Reference [3]). The PTR field can only be set to “000”.
Samsung Electro-Mechanics Co., Ltd. Proprietary 5.4.1 Connect (CP → PS → SMS → CP SMS Connect) 5.4.2 Disconnect (CP → PS → SMS → CP SMS Disconnect) 5.4.3 Broadcast Connect (CP → PS → SMS → CP SMS Bcast Connect) 5.4.4 Broadcast Disconnect (CP 5.4.5 User Ack (CP → PS → SMS → CP SMS Bcast Disconnect) → PS → SMS → CP SMS User Ack) 5.4.6 Service Option Pref (CP 5.4.7 Cancel (CP REV 0 → PS → SMS → CP SMS Srv Opt Pref) → PS → SMS → CP SMS Cancel) 5.4.8 Broadcast Parameters (CP 5.4.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 3. Open File->Flash Download, you can see the flash memory download dialog, see the following bitmap. Select the drop down box CP Boot for Flash Section; click the Browse to set your new boot.rom path, set “wait for boot load command” check box on, then the “Download” button will be disabled. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 4. Power OFF the phone, connect the phone with PC and Power ON the phone, “Wait for boot load command” check box becomes unchecked, and “Download” button is enabled. You will see “CP Boot Loader” in the ETS Log Window. 5. Click “Download” button to begin download boot.rom, you can see the CP Flash Download dialog. ETS erases the flash, and then begin to write boot.rom in flash, and you can see the download progress. Samsung Electro-Mechanics Co.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 6. Open File->Flash Download, you can see the flash memory download dialog, see the following bitmap. Select the drop down box CP for Flash Section; click the Browse to set your new cp.rom path, set “wait for boot load command” check box on, then the “Download” button will be disabled. 7. Power OFF the phone, then Power ON the phone again, “Wait for boot load command” check box becomes unchecked, and “Download” button is enabled.
Samsung Electro-Mechanics Co., Ltd. Proprietary You will see “CP Boot Loader” REV 0 in the ETS Log Window. 8. Click “Download” button to begin download cp.rom, you can see the CP Flash Download dialog. ETS erases the flash, and then begin to write cp.rom in flash, and you can see the download progress. 9. After download finished, power off the phone (If there is a battery in your phone, please remove and re-insert), then power on the phone.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Flash Section: Options CP Boot CP DSPM DSPV ALL FLASH FSM_DATA/FSM _USER Path Print Cmds Print Response Download Exit REV 0 Definition Downloads CP Boot code to flash memory when Download is clicked. Downloads CP code to flash memory when Download is clicked. Downloads DSPM code or DSPM patches to flash memory when Download is clicked. Downloads DSPV code or DSPV patches to flash memory when Download is clicked.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Flash ID CP → Flash → CP Flash ID Used to display the type and manufacture of the Flash device in usi. The customer must update hwdflash.c if any other than the AMD AM29DL163CB flash is used. Window Selections Send Definition Data that is displayed in the Main Log window when Send is clicked in the above example. 10:17:40.1< ETS, Id=CP Flash Id 10:17:40.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Flash Erase CP → Flash → CP Flash Erase Window Selections Options Send Tack Section Type CP Boot CP DSPM DSPV All Definition Data that is displayed in the Main Log window when Send is clicked in the above example. When checked, window will remain on screen after every Send. When not checked, window will close after a Send Selects the CP Boot section of Flash. Selects the CP section of Flash. Selects the DSPM section of Flash.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.5.2RF Calibration Data Hwd AFC Data CP→DB→DB Templates→Common→CP DB HWD AFC Data Hwd Battery Data CP→DB→DB Templates→Common→CP DB HWD Battery Data.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 PCS TxAGC Limit Temperature Adjustment CP→DB→DB Templates→ BAND B →CP DB HWD BAND B Tx Limit Temp Adj. PCS TxAGC Closed Loop RF Power Measurement CP→DB→DB Templates→ BAND B →CP DB HWD BAND B Tx Pwr Detect PCS TxAGC Closed Loop Frequency Channel Adjustment CP→DB→DB Templates→ BAND B →CP DB HWD BAND B Tx AGC Pwr Det Freq Chan Adj.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 CELL Tx AGC Limit Freq Chan Adj CP→DB→DB Templates→ BAND A →CP DB HWD BAND A Tx Limit Freq Chan Adj CDMA TxAGC Max Power Limit Temperature Adjustment CP→DB→DB Templates→ BAND A →CP DB HWD BAND A Tx Limit Temp Adj. CELL TxAGC Closed Loop RF Power Measurement CP→DB→DB Templates→ BAND A →CP DB HWD BAND A Tx Pwr Detect CELL TxAGC Closed Loop Frequency Channel Adjustment CP→DB→DB Templates→ BAND A →CP DB HWD BAND A Tx AGC Pwr Det Freq Chan Adj.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Clear MRU CP → PS →Database→ CP Clear MRU Window Selections Send Tack Definition The MRU (Most Recently Used Channels) is a list of (Band, Channel #) which is stored in Flash. At Power Up the CBP4 software first scans the channels in the MRU, and then goes to the PRL. Clearing the MRU ensures that the PRL will be scanned first. This command is particularly useful when a new PRL is downloaded to the phone.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Send Tack Active NAM REV 0 --NAM1 NAM2 Definition Send to set the active NAM If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Set the A-Key CP → PS → Database → CP Enter A Key Window Selections Options Send A-Key Checksum ESN Definition Send to write the A-Key 20 decimal digit A-Key 6 digit checksum 32-bit (8 hexadecimal) ESN Some Notes Regarding this command: 1. The A-Key is only updated in the Active NAM. Therefore the Select Active NAM command should be executed prior to this Akey command to explicitly select the NAM where the Akey should be updated. 2.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Data services PRL Voice Memo 1 Voice Memo 2 Voice Rec 1 Voice Rec 2 5.5.4DB Clear, Flush, Cache 5.5.5DB Write 5.5.6DB Read 5.6 Software Operation Status 5.6.1Software Version CP, DSPM, DSPV, ETS CBP Version CP → MON → CBP Version Window Selections Send Tack Definition Send to Log Details of CBP version in the ETS Main Log Window If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 CP Version CP → MON → CP Version Window Selections Send Tack Definition Send to Log Details of CP Flash code in the ETS Main Log Window If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 DSPM Version DSPM → DSPM Version Window Selections Send Tack Definition Send to Log Details of DSPM Flash code in the ETS Main Log Window If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.6.2Memory Peek CP Peek CP → MON → CP Peek Window Selections Options Send Tack --- Address -- Definition Send to Peek the CP Memory Location(s) or Register(s) If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Address of CP Memory or Register Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Words(16) Addr Adv Options REV 0 Definition -Memory (advanced by 2 bytes) Register (advanced by 4 bytes) Number of words, up to 16 to Peek. Valid values: 1-16 Use this option to Peek Memory Use this option to Peek Registers DSPM Peek DSPM → DSPM Peek Window Selections Options Send Tack Definition Send to Peek the DSPM Memory Location(s) or Register(s) If checked, the window will remain after clicking “Send”.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.6.3Memory Poke CP Poke CP → MON → CP Poke Window Selections Send Tack Address Words(16) Addr Adv Options ----Memory (advanced by 2 bytes) Register (advanced by 4 bytes) Definition Send to Poke the CP Memory Location(s) or Register(s) If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Address of CP Memory or Register Number of words, up to 16 to Poke.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Send Tack REV 0 Definition Send to Poke the DSPM Memory Location(s) or Register(s) If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Address of DSPM Memory or Register Number of words, up to 16 to Poke.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.6.4Disabling All Spies And Traces 5.6.5Msgs Buffer Stats Spy CP → Spy → MON → CP Msg Buff Stats 显 示消息缓 冲区 的信息。 Window Display Print Sys Time Num Msg Buffs In Use Max Num Msg Buffs Used Num Msg Buffs[1:4] In Use Max Num Msg Buffs[1:4] Max Msg Buff[1:4] Size Description 如果选中,窗口中的信息将显示在 main log window 中 当前从缓冲区 1-4 中分配的消息总数量 曾经从缓冲区 1-4 中分配的消息的最大数量 缓冲区 1-4 中,当前分配的消息数量 缓冲区 1-4 中,曾经分配的消息的最大数量 缓冲区 1-4 中,可分配的消息的最大字节数 5.6.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 显 示任务 消息队 列的状态 。 Window Display Print Sys Time Task Id Num Msgs Explanation 如果选中,窗口中的信息将显示在 main log window 中 任务 ID 任务消息队列中的消息数量 5.6.7Msgs Buf Ptr Stats Spy CP → Spy → MON → CP Msg Buff Ptr Stats Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 显 示消息指针 的有关 信息。 Window Display Print Sys Time Alloc By Task Sent To Task Msg Id Explanation 如果选中,窗口中的信息将显示在 main log window 中 创建消息的任务 接收消息的任务 消息 ID 5.6.8Action Time Stats CP->Spy->MON->CP Action Time Stats Window Display Explanation Print Sys Time Num Action Times In Use Max Num Action Times Used Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5.6.9Clear TDSO Stats 5.6.10 Clear FER 5.7 CBP Hardware 5.7.1HW Version 5.7.2Reset Processor CP, DSPM, DSPV 5.7.3Initializing Hardware Control 5.7.4Hwd Init CP → HWD → HWD Init Window Selections Send Tack Definition Send to Initialize Hardware Drivers If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. 5.7.
Samsung Electro-Mechanics Co., Ltd. Proprietary Window Selections Options Tack -- AUX ADC Channel AUX ADC Ch[0-15] Tx PCG Sync Off On REV 0 Definition If checked, the window will remain after clicking “Send”. If not checked, window will close after clicking “Send”. Read the Relevant AUX ADC Channel. There are 16 channels [0-15] Take the AUX ADC reading immediately Wait till an Active PCG to make a measurement.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 2. Open ETS. 3. Run script thru Utilities -> Script Utility. In the Script, Select Script->Record command to let Script application in Recording status. Then Script.exe will record all commands that printed in ETS main window. 4. In ETS application, select CP->DB->CP DB NAM LOCK command to unlock the NAM. Then select CP->DB->DB Templates->common->CP DB NAM 1 command to open the dialog of CP DB NAM1.
Samsung Electro-Mechanics Co., Ltd. Proprietary Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 5. Click the “Read” commands in all dialog, For example In CP DB NAM1 dialog press the key “Read” to read NAM1 data from the phone, and in “CP DB HWD BAND A Rx AGC “ dialog , press the key “Read” to read Rx AGC data from the phone. Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 6. Then in ETS, click “Write” in all dialogs that you have opened. In CP DB NAM1 dialog press the key “Write” to write NAM1 data into the phone, then this command will be printed in ETS main window and be sent to Script.exe. It will be recorded in the Script.exe main window. In “CP DB HWD BAND A Rx AGC “ dialog press the key “Write”, the Rx AGC data will be recorded into script main window. (See Picture <4>) Samsung Electro-Mechanics Co., Ltd.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 7. Switch to script, select Script->Record, to stop recording the script, and save the script in a file. The file will be saved as *****.srp. Then you have recorded the NAM1 data in a script file. Note: Usually if you want to run the write NAM data into the phone, you should set the NAM unlock. So you need add the command “ETS, Id=CP DB NAM Lock, DB NAM Status=Unlock, Confirm Change=No“ in the first line of script file.
Samsung Electro-Mechanics Co., Ltd. Proprietary REV 0 Revision History Revision 1 2 2 Date 2012-06-05 Descriptions Created Samsung Electro-Mechanics Co., Ltd.