Professional UHF Wireless System OWNER'S MANUAL
Important Safety Information 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
Introduction Congratulations on purchasing the Samson Synth 7 wireless system. The Synth 7 is the ideal solution for the active performer who needs a reliable, great sounding system for wireless applications. Synth 7 system features all-metal components with easy-to-read displays and advanced menu functions for seamless operation. The Synth 7 comes in five configurations. The vocal handheld system includes the UH7 handheld transmitter with a Q8 dynamic microphone capsule.
Quick Start In order for your wireless system to work correctly, both the receiver and transmitter must be set to the same channel. Set up the receiver: Physically place the UR7 receiver where it will be used. The general rule of thumb is to maintain “line of sight” between the receiver and transmitter so that the person using or wearing the transmitter can see the receiver. Connect and position the antennas vertically. Connect the included power adapter to an outlet. SR266 Receiver FREQ: 518-546.
Quick Start Multiple System Setup Press and hold the power button to turn on the UR7 receiver. Press the Menu/Select button to enter the Main Menu. Rotate the Menu/Select encoder to highlight GROUP & CHANNEL and press the MENU/SELECT button to enter the menu. Set each receiver to the same Group. Select GROUP and press the MENU/SELECT button. The Group letter will start to flash.
UR7 Receiver Callouts 1 2 3 4 5 1 1. Antennas Jacks - The BNC antenna jacks allow full rotation for optimum placement. In normal operation, both antennas should be placed in a vertical position. 2. POWER Switch - Press and hold this to power the receiver on or off. A quick press of the button will move back through the menus. 3. IR Transmitter - During “IR SET” an infrared code (similar to selecting a channel with a TV remote) is used to set the transmitter channel. 4.
UB7 Callouts 1. Input Connector - Connect the input device via the mini-XLR connector. 1 2 2. Power/Mute Switch - Press and hold to turn the unit on or off. Press and release to mute or unmute the transmitter. 3. Antenna - Permanently attached transmitter antenna. 4. Belt Clip - Use this clip to fasten transmitter to a belt or guitar strap. 3 5. UNLOCK/LOCK Switch - Locking the system controls prevents accidental muting or channel adjustment during performance. 6.
UH7 Callouts 1. LCD Display - Displays the current group,channel and battery level information. 2. Power/Mute Switch - Press and hold to turn the unit on or off. Press and release to mute or un-mute the transmitter. 3. UNLOCK/LOCK Switch - Locking the system controls prevents accidental muting or channel adjustment during performance. 4. Battery Holder - Open the battery holder by pressing the tab and lifting the cover.
UR7 Operating Menu The UR7 receiver features a user friendly operating menu, with extensive features and adjustable parameters. This enables the receiver and transmitter to be quickly and easily set up for performance. Controls POWER Button Press and hold switches the receiver on and off Short press cancels an entry and returns to the current menu Short press moves back through the menus.
Menu Parameters Group & Channel Group Manually adjusts the operating Group Channel Manually adjusts the channel with the selected Group Scans the current selected group channels and selects the cleanest Group Scan signal to use for optimal performance Sends the group and channel information to the UH7 and UB7 IR Set transmitters via the infrared set. Frequency Select Frequency Manually adjust the operating frequency of the UR7 receiver.
Group & Channel Menu Group & Channel Group Channel Group Scan IR Set Back Group & Channel A 01 Group Channel Group Scan IR Set Back Group & Channel B 01 Group Channel Group Scan IR Set Back Group & Channel B 01 Group Channel Group Scan IR Set Back B 02 From the main performance page, press the MENU/SELECT button to enter the Main Menu. With GROUP & CHANNEL highlighted, press the MENU/SELECT button to enter the GROUP & CHANNEL submenu.
Frequency Select Menu Frequency Select Frequency Select 518.000MHz 546.850MHz Scan Spectrum IR Set Back Scan Spectrum IR Set Back From the main performance page, press the MENU/SELECT Button to enter the Main Menu. With FREQUENCY SETUP highlighted, press the MENU/SELECT button to enter the FREQUENCY SETUP submenu. Setting the Operating Frequency Rotate the cursor to select the Frequency parameter. Press the MENU/SELECT button to adjust the setting.
Audio Setup Audio Setup Audio Level HPF Back Audio Setup 01 OFF Audio Level HPF Back 12 OFF From the main performance page, press the MENU/SELECT Button to enter the Main Menu. With AUDIO SETUP highlighted, press the MENU/SELECT button to enter the AUDIO SETUP sub-menu. Setting the Audio Level Rotate the cursor to select the AUDIO LEVEL parameter. Press the MENU/SELECT button to adjust the setting. Rotate the MENU/SELECT knob to adjust the output level setting.
Advanced Setup Advanced Setup Squelch Tone Key Contrast Lock Back Advanced Setup LOW ON 01 ON Squelch Tone Key Contrast Lock Back LOW OFF 01 ON Enabling the Tone Key Rotate the cursor to select the TONE KEY parameter. Press the MENU/SELECT button to adjust the setting. Rotate the MENU/SELECT knob to turn the TONE KEY on or off. Press the MENU/SELECT button to confirm and store the setting. Press the POWER button to cancel the selection and move back to the ADVANCED LEVEL sub-menu.
Rack Mounting The UR7 receiver can be installed into a standard 19” rack for transport or permanent installation using the included rack ears. Affix the included rack ears to each side of the UR7 receiver. Secure the rack ears in place using the screws provided. Position the UR7 receiver into an available rack space and slide in until the rack ears are touching the rails of the rack case and are aligned with the rack rail holes.
Channel Plans Group C 638-666MHz A B C` D E F G H I J 1 638.000 638.200 638.225 638.300 638.425 638.950 639.000 639.200 639.225 639.300 2 640.525 640.725 640.750 640.825 640.950 641.475 641.525 641.725 641.750 641.825 3 643.150 643.350 643.375 643.450 643.575 644.100 644.150 644.350 644.375 644.450 4 645.875 646.075 646.100 646.175 646.300 646.825 646.875 647.075 647.100 647.175 5 648.700 648.900 648.925 649.000 649.125 649.650 649.700 649.
Specifications System Working Range Audio Frequency Response T.H.D.