User Manual Product Name: Heart rate module 3300 series Model:HRM3300,3300 series Brand: SALUTRON Manufacture: Salutron Inc.
CONFIDENTIAL Revision History: Revision Release date Description By 0.1 11/29/16 Preliminary Draft BC 0.2 12/22/16 Changed output pin assignments BC 0.3 01/30/17 MC/BC 0.4 02/10/17 Revised Uart communication protocol, added response bit Corrected UART package table 0.5 02/14/17 Revised general description(page4) BG 0.6 02/24/17 PCBA picture updated, and revised flow chart BC 0.7 02/28/17 Added FCC/IC statement BC 0.
CONFIDENTIAL Contents General Description .............................................................................................................................. 4 Features: ............................................................................................................................................. 4 Physical Dimensions: Inches (mm) ......................................................................................................... 5 Connection Diagram: (Typical) .............
CONFIDENTIAL Model 3300 Series Wireless Heart Rate Monitor Specifications General Description x The Model 3300 Wireless Heart Rate Monitor is designed to manage and support the reception of heart rate data from either 2.4G digital BLE or ANT+ chest straps and wearable devices, and standard 5kHz chest straps. x Once enabled by the Console, the Model 3300 actively scans for local strap/device signals, and supports a user selection/pairing protocol processed by the Console.
CONFIDENTIAL Physical Dimensions: Inches (mm) Figure 1: Physical dimensions Connection Diagram: (Typical) TYPE J1 – Main Copyright 2016, Salutron, Incorporated PIN No. DESCRIPTION 1 GND 2 VCC 3 TXD 4 RXD Revision 1.
CONFIDENTIAL Electrical Characteristics: Symbol Parameter Conditions Min. Typ. Max. Units VS Supply voltage - 3 5 6 V IS Supply current Vcc = 5V 5.5 Operating Temperature - 10.5 60 mA To 5.2 -10 Ts Storage Temperature - - -40 - °C 85 °C 5KHZ Wireless Specification: Parameter Conditions Min. Typ. 5KHZ Wireless reception range Noise free environment 31 80 5KHZ Wireless reception frequency T= 25ºC, Vcc =5.0V 4.8 5.3 5.9 KHz Heart rate detection T= 25ºC, Vcc =5.
CONFIDENTIAL Output power Open Air range -20 - 4 dBm - - 10 Meter Vdd=5.0V @ 25°C Power Consumption - 5.5 - mA Device Searching Mode - 10 10.5 mA Heart rate Data transfer - 5.5 5.6 mA - - 33 Feet - - 10 Meter Copyright 2016, Salutron, Incorporated Revision 1.1 Standby mode Operation Modes 2.
CONFIDENTIAL 1. UART COMMUNICATION PROTOCOL: The following section describes the communication protocol between the HRM3300 and Equipment console. The protocol is intended to provide a reliably link between the HRM3300 and Equipment console. The UART protocol supports the two way link communication between the two devices. 1.2.Block Diagram 2. OPERATION 2.1. Description The Equipment console and HRM3300 uses standard UART protocol to transmit and receive custom packets.
CONFIDENTIAL 2.2. UART Specification Baudrate: 9600 (default), 4800, 2400, 115200 Parity: No parity Flow Control: Disable 2.3. Equipment Assumption Upon power up of the equipment device, the HRM3300 is also power up. Since the equipment is controlling the HRM3300, the HRM3300 will be on the idle state or waiting state for the command from the equipment console. 2.4.
CONFIDENTIAL 2.5. HRM3300 Programming flow Copyright 2016, Salutron, Incorporated Revision 1.
CONFIDENTIAL Copyright 2016, Salutron, Incorporated Revision 1.
CONFIDENTIAL Copyright 2016, Salutron, Incorporated Revision 1.
CONFIDENTIAL 2.6. HRM3300 OTA. The new code update can be flashed into the device using over the air programming. The BLE DFU feature of OEM3300 can be triggered using the activation command from the console. Once triggered the OEM3300 function as BLE peripheral and will broadcast “OEM_3300”. Using Nordic NRF Connect application installed in the phone and the OAD zip file released, the OEM3300 firmware can be updated.
CONFIDENTIAL 3. UART COMMUNICATION PROTOCOL PACKETS 3.1. Packets The uart protocol packets contain data that will be used as an interface between the HRM3300 and the equipment console. A maximum of twenty four bytes and a minimum of eight bytes are used during Uart communication. Fletcher checksum reference: https://en.wikipedia.org/wiki/Fletcher%27s_checksum For 5kHz analog strap, the name to be transmitted will be “5kHz HRM”.
CONFIDENTIAL [Name … byte] [Name xth byte] Packet: ex. 5Khz advertising name = “5kHz HRM” [0x0A] [0x0F] [0xYY] [0xZZ] [0x0C] [0x00] [0x01] [0x35] [0x6B] [0x48] [0x7A] [0x20] [0x48] [0x52] [0x4D] 3.3. Example of Sending Packet to HRM3300 Usage: Sending selected packet name to HRM3300 Format: [Start Command] [Packet Size] [Fletcher check sum low byte] [Fletcher check sum high byte] [Response bit] [Class] [Sub Class] [Name 1st byte] [Name … byte] [Name xth byte] Packet: ex.
CONFIDENTIAL 3.4.
CONFIDENTIAL ACKNOWLEDGEMENT ACLK RSSI Value 0x0A 8 0xYY 0xYY 0x00 0x0C 0x07 0x01 5Khz name 0x0A 8 0xYY 0xYY 0x00 0x0D 0x01 0x01 BLE RSSI Data 0x0A 8 0xYY 0xYY 0x00 0x0D 0x10 0xYY ANT+ RSSI Data 0x0A 8 0xYY 0xYY 0x00 0x0D 0x20 0xYY EQUIPMENT CONSOLE TO HRM3300 CONNECTING Sending 5Khz Name
CONFIDENTIAL 3.5.
CONFIDENTIAL Page 18 Get data page 18 0x0A 8 0xYY 0xYY 0x00 0x23 0x01 0x01 0x0A 8 0xYY 0xYY 0x00 0x24 0x01 0x01 0x0A 8 0xYY 0xYY 0x00 0x25 0x01 0x01 0x0A 8 0xYY 0xYY 0x00 0x26 0x01 0x01 0x0A 8 0xYY 0xYY 0x00 0x27 0x01 0x01 Page 21 Get data page 21 Page 80 Get data page 80 Page81 Get data page 81 DEVICE ID Get Device ID Copyright 2016, Salutron, Incorporated Revision 1.
CONFIDENTIAL Appendix A : HRM3300 Placement Guideline The electrical noise generates from the machine could affect the reception range of 5KHZ wireless receiver. It is better to avoid any noise frequency near 5KHZ or harmonics get near the module. Although not all electrical noise can be avoided, the following sources could contribute to the interference. It is recommended to position the HR wireless module as far from these sources as possible.
CONFIDENTIAL The ideal placement location of the HR wireless module would be at the center, toward the front that is closer to the user, and away from the noise sources. In case the wireless module has to place off to the left or right side from the center of the console, then try to keep the offset distance within 12 inches (30cm) or less, otherwiseThe reception distance of the HRM will be shorten if it is placed too far off from the center. Copyright 2016, Salutron, Incorporated Revision 1.
CONFIDENTIAL FCC/IC statement FCC statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
CONFIDENTIAL FCC/IC statement When the module is installed inside another device, the user manual of the host must contain below warning statements; 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2.
CONFIDENTIAL Order Information Salutron’s commitment to customer satisfaction is the driving force behind our product offerings. Contact us to discuss any specific connector options, preloaded features, and specific application information that you may need. Life Support Policy Salutron’s products are not authorized for use as critical components in life support devices. Contact Information Salutron Inc.