Quick Start Guide

Quick Start Guide: Low Voltage Contact Relay (SC824ZB)
IN THE BOX
SAFETY INSTRUCTIONS:
Read these instructions carefully before installing and
using the Low Voltage Contact Relay and keep this guide
in a safe place for future reference.
Verify compatibility with your associated
connected home system before installation.
Follow all instructions provided by your connected
home manufacturer regarding the addition of
devices to your connected home system. An
authorized, qualified installer may be required.
Follow all applicable codes and regulations in the
municipality where this product is installed.
Salus accepts no responsibility for damage caused by not
following these instructions.
Low Voltage Contact Relay
Quick Start Guide
NOTE:
Additional equipment may be required to address
radio communication issues due to building
construction or materials, or other radio interference.
CONTROLS AND INDICATORS
PAIRING INSTRUCTIONS
Prepare to add devices per your system’s instructions.
Power up the Low Voltage Contact Relay (LVCR).
When the LVCR is detected, follow your system’s instructions to finish adding the switch to the system. You may
need to press the Multi Button to identify the switch.
USING THE LOW VOLTAGE CONTACT RELAY (LVCR)
TURN OFF/ON
To toggle the LVCR (turn ON when OFF, or turn OFF when ON), press the Multi Button briefly.
FORCE REJOIN TO CURRENT NETWORK
To find a better path to the connected home system if the network is intermittent and/or other ZigBee devices
are added/deleted, press the Multi Button 5 times quickly (less than ½ sec between presses).
IDENTIFY MODE
To initiate Identify Mode, press the Multi Button until the LED turns Amber (~3 seconds), then release. The LED
will then alternate between RED and GREEN. Wait 3 seconds and the device will enter Identify Mode and flash
the LED accordingly.
RESET TO FACTORY DEFAULTS
To reset to factory default settings, press the Multi Button until the LED turns Amber (~3 seconds), then release.
The LED will then alternate between RED and GREEN. Press the Multi Button again until the LED turns Amber (~3
seconds), then release. The device will factory reset and return to normal operations.
Multi Button
Terminal
Strip
LED
Function
AMBER (RED + GREEN)
Power up
3 RED flashes
Network Search
Steady GREEN
Relay is Closed
No LED
Relay is Open
Long GREEN
Short RED
Relay is Closed,
no network
No LED
Short RED
Relay is Open
no network
Short GREEN
Short RED
Special Function
Mode
Long GREEN
Short AMBER
Relay Closed,
Identify
No LED
Short AMBER
Relay Open,
Identify
Terminal
Function
R (x2)
Power Input
C (x2)
Power Return
COM
Common relay contact
NO
Normally Open relay contact
Action
Function
Short press
Toggle output
Press 5x
Join/Rejoin network
Hold 3s
Enter Special Functions (SF)
SF: no press
Identify
SF: Hold 3s
Factory Reset
SPECIFICATIONS
Input Voltage
18-30 VAC
Input Current
30 mA,
50 mA max
Contact Voltage
30 VAC max
Contact Current
3 A max,
resistive