User's Manual Part 1

G1 G2
24
VAC
Group 1 thermostats Group 2 thermostats Stand alone thermostats
AKL08RF Zigbee Zone Wiring Center
Installation and Wiring Guide
For PDF Installation guide go to www.salusna.com
Maintaining a policy of continued product development SALUS Controls plc reserves the right to change
specification, design and materials of products listed on this installation guide without prior notice.
Issue Date: Dec 2016
www.salusna.com Technical Helpline 1-650-360-1725
Remove the white plate in order to reach the
power cord terminals for 120VAC supply.
Loosen the wire connectors and insert
wires for the power, boiler and pump.
Install wires in their respective locations.
Tighten the wire connectors to secure the
wires. See section 8 for more info.
Optional boiler
Connection
Heat/ Cool changeover
(Open = heat, closed = cool)
Dew point sensor
External Power Supply
L N PG
N
L
DRY CONTACTS
ONLY
UNDERFLOOR HEATING
MANIFOLD
120VAC TO UFH PUMP
Cables will be supplied
by the installer
These instructions apply to the SALUS
model stated above.
Warning
This product must be fitted by a competent person,
and installation must comply with the guidance,
standards and regulations applicable to the country
or state where the product is installed. Failure
to comply with the requirements of the relevant
guidance, standards and regulations could lead to
injury, death or prosecution.
Warning
Always isolate the AC main supply before installing
or working on any components that require 120 V
AC 60Hz supply.
The ground terminals on the AKL08RF are for ground
connections only. These terminals provide no earth
protection.
INFORMATION
The wire connectors used for
securing the wires are sold
separately.
i
Remove the High Voltage
cover access to the Boiler
and Pump terminals.
i
INFORMATION
If you are mounting the Zone Wiring
Center on a stud wall, extra support
may be required.
L Live connection
H Hot
N Neutral
PG Ground
Fuse 4 Amp
G1 Group 1 Thermostats
G2 Group 2 Thermostats
CO Change Over (Heat/Cool)
AS20RF AS20RF AS20RF AS20RF AS20RFAS20RF AS20RF AS20RF
Stephen Wu
2016-11-11
SALUS Project:
AKL08 - RF Wiring Center
(SW0012 / Rev 10)
Transparent matt gray(same color and
surface nishing with old KL08 cover)
silk print white
matt surface nishing, same black
color with old KL08 body
gloss white(same color and
nishing with old KL08)
logo& warning mark: high
gloss surface nishing
Color Spec
8
6 5 9 4
7
13
11
i
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device complies with Industry Canadas licence-exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of
the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence.
Lexploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm
from all persons.
Les antennes utilisées pour cet émetteur doivent être installées pour fournir une distance de séparation au
moins de 20 cm de toutes les personnes.
L
N PG
L N PG
PG
Electrical connections
4 Amp

Summary of content (1 pages)