INSTALLATION AND OPERATION MANUAL Please read these instructions completely before installing or operating the E-one fireplace. NetZero E-one Electric Fireplace Models: AA-11-05384 – NZ E-one 100 Description of the remote control: Page 13 IMPORTANT Please read these instructions carefully before installation. Failure to follow them could result in serious injury. This appliance must be installed by a qualified installer.
Table of contents 1 Introduction 3 1.1 Receiving inspection 3 1.2 Certification 3 2 General safety regulations 3 2.1 Additional general safety regulations for Atmos Heating 4 2.2 California proposition 65 warning 4 3 Warranty 5 4 Assembly of the fireplace 5 4.1 Removal of covers 5 4.2 Rear screen assembly 5 4.3 Top screen assembly 6 4.4 Installing the fireplace 6 4.5 Placing design bottom plates 7 4.6 Placing lower sidewalls 7 4.7 Log set installation 8 4.8 Placing glass reflector 10 4.
1 Introduction Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NetZero Fire stands for innovation and quality. This is why NetZero Fire works continuously on the further development of its products. We reserve the right to make changes to the form, technology, and design of the products we sell. No claims can be made on the basis of information and figures from this manual.
• 2.1 • • • • • • • three to seven years old must not clean the fireplace or perform user maintenance. If the power lead becomes damaged, it must be replaced by the supplier or another qualified service provider to avoid danger. Additional general safety regulations for Atmos Heating The fireplace does not have an automatic temperature regulator. If the fireplace is installed in a small room, each person present in the room must be able to leave the room independently.
3 Warranty We stand behind the quality of our products and therefore the warranty period on our electric fireplace is five years or up to 10,000 burning hours. For the Atmos Heating function of the fireplace we offer a two-year warranty. 4 Assembly of the fireplace Do not use tie wraps to re-fasten cables during installation. 4.1 Removal of covers 4.
4.3 Top screen assembly 4.4 Installing the fireplace Place the fireplace in its final position before continuing to fill from the front. Once you have levelled the fireplace, it is strongly recommended that you attach it to the wall using the wall brackets for added stability and safety.
4.5 Placing design bottom plates 4.6 Please note: If a flat bottom plate was chosen, this step can be skipped. The flat base plate is pre-installed during production. Placing lower sidewalls The design bottom plates are made of vulnerable material. Therefore, proceed with extreme caution when installing the bottom plates. Make sure that the back of the lower side walls are parallel to the rear wall.
4.
C F H 9 K L
4.8 4.10 Placing glass reflector Placing front window The glass reflector is susceptible to stains and fingerprints. For this reason, always use the supplied gloves for installation. To clean the glass reflector, follow the cleaning instructions provided in chapter 7. 4.9 Placing upper side walls When placing the front window, make sure the front window is parallel to the frame of the fireplace.
4.11 Connecting fireplace to power 5 This fireplace must be hardwired to a 120V, 60Hz, 15Amp electric supply. Install on a dedicated 15Amp (or higher) breaker. This appliance must be grounded. Wiring procedures and connections shall be in accordance with the national and local codes having jurisdiction. Installing the fireplace 5.1 Light / illumination 5.2 Viewing height 5.3 Service area The E-one functions on the basis of hologram technology.
5.6 Fireplace finishing in combination with Atmos Heating Maintain a minimum clearance of 1/16 in. (2 mm) between the surround and the fireplace for heat transfer and expansion. Too little space will result in temperatures above 176 °F (80 °C) and unwanted material stresses.
6 E-one operation, design your own experience Power Button This button has three functions: On, Anti-Reflect, Off. Switching the fireplace On Briefly press the power button. It takes about 30 seconds for the fireplace to fully start up. With the E-one you can create your own fire experience through the various functions and/or options. 6.1 Anti-Reflect Function When the fireplace is on briefly press the power button to turn the fireplace off with the anti-reflect mode activated.
6.2 Main on/off switch Power to the fireplace can be switched off using the on/off switch (0/I) on the front. The button is located at the top right, behind the metal flap (see figure). Lift the metal flap a little towards you. If the unit is completely disconnected from power, the unit will be reset to the factory settings.
7 Maintenance CAUTION: Before cleaning, make sure the power has been turned off at the circuit breaker panel and that the heating element of the heater is cool. 7.1 Cleaning the fireplace 7.2 Cleaning glass reflector Use a microfiber cloth or other soft cloth to clean the black powder-coated parts of the stove. The use of sandpaper, steel wool or brushes and scouring pads is strictly not recommended. This will leave scratches on the coating.
8 Technical data 8.1 Specifications Model: NetZero E-one 100 Input: 120V – 60Hz – 15Amp Power: 1350 Watt Heater output: 4,350 Btu/hr Energy consumption per operating mode standby mode (W) standby mode, incl. anti-reflect function (W) full operating mode, excl. Atmos Heating (W) full operating mode, incl. Atmos Heating (W) 1.4 17 75 1350 This fireplace must be hardwired to a 120V 15Amp electric supply.
8.3 Wire diagram 8.
NETZEROFIRE.COM NetZero is a distributor of these products, which are designed and manufactured by Kalfire B.V. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF AND SUPPLIED MANUALS. IMPLIED WARRANTIES OF MERCHANTABILITY, IMPLIED WARRANTIES OF FITNESS, IMPLIED WARRANTIES OF WORKMANSHIP AND OTHER IMPLIED WARRANTIES ARE EXCLUDED BY NETZERO.