Installation Instructions

Product Summary
The Indoor Keypad Model XMB611 is designed for use in
configuring/programming and operating a Videofied
TM
security
system. The keypad includes the following features:
>
Lithium batteries for long life.
>
2-line, 16-character alphanumeric LCD display
>
Built-in badge reader for arming/disarming
>
Built-in piezo for status and alarm sounds
>
Dual tamper function provides detection of both
wall and cover tamper.
>
Transmits check-in/status signal every 8 minutes.
Installation Guidelines
For easier installation, programming and RF testing
should be completed before mounting the control panel and
devices.
Install the keypad and other system devices in the following
order:
>
Programming/RF Testing - Program keypad and all other
devices into the control panel and test RF communication
from each intended device location to the control panel.
>
Mounting - Mount keypad and devices at the tested location.
Programming/RF Testing*
1
Open the casing by turning the button toward the opened
padlock symbol and press down lightly on the button to
separate the cover.
2
Insert 3 (minimum) or 4 (for longer life) SAFT 3.6v Lithium
AA LS14500 batteries.
3A
New Installation: Put the control panel into
keypad registration mode by pressing the
programming button of the control panel one time.
OR
3B
Adding to existing system: Using a programmed
alphanumeric keypad, proceed through menus until the
display shows ADD A NEW DEVICE. Press Yes. The
display shows PRESS PROGRAM BUTTON OF DEVICE.
OR
3C
Adding to existing system without a keypad: Refer to
the installation manual of the control panel.
4
Press and release the programming buttons (CLR and
ESC/NO) on the XMB keypad. The keypad LED will flash.
Wait for keypad display to show KEYPAD# RECORDED.
5
Press Yes. The display shows LANGUAGE: ENGLISH. Press
Yes. (This prompt will only appear when performing a
new installation).
6
Display shows RADIO RANGE TEST? Press YES, the
keypad starts displaying the number of successful pings
to and from the control panel out of 9 (0/9 to 9/9).
Devices must be installed in a location with a stable 9/9 RF
test result to ensure reliable communication.
7
Press YES to end radio range test, then press Esc/No.
Note: If this is a new installation (3A), the keypad display
prompts other system configuration data. If adding a keypad to
an existing (operational) system, proceed to step 8.
8
When finished, exit from configuration mode.
Note: The control panel automatically assigns alphanumeric
keypads automatically to Area 1 (Entry/Exit delay)
*For complete details, refer to the control panel installation manual.
www.videofied.com
INSTALLATION DATA SHEET
Keypad XMB611
Made by RSI VIDEO TECHNOLOGIES 1010-XMBIN February 2012

Summary of content (5 pages)