Security System Made by RSI VIDEO TECHNOLOGIES Videofied ® - Model XL GPRS Document No. 2100-XL Jan. 2010 Installation Manual Subscriber linked to the monitor station by GPRS for video and audio confirmation XL GPRS means XL600GPRS for USA/Canada, XL700GPRS for Australia and XL200GPRS for Europe and rest of the world.
Contents Preamble...................................................................................... 1 1. Preparation before programming............................................ 2 2. The golden rules .................................................................... 3 3. Installation and programming ................................................. 3 3.1 Initialize the panel........................................................................3 3.2 Record the keypad................................
Preamble The XL GPRS panel is specially designed for monitoring. It incorporates the main functions available in the VISIO panel range, including in particular: - Video verification - Radio range measurement - A 24/24 area - Automatically scheduled rearming (15 mins to 2 days) - The immediate processing of contacts opened during the arming.
1. Preparation before programming On a piece of paper : • Define the partial arming profiles (combinations of A geographical zone corresponds to a surface where all the sensors are armed/disarmed together. A partial arming profile is a combination of geographical zones which are either armed or not. By using the examples below, you are going to meet most of the requirements. • Ask the end user to prepare his/her codes (18 areas, see paragraph 5 and the partial programs on page 7).
2. The golden rules 14 The keypad becomes inactive after 40 seconds of inactivity, in order to make the display to reappear, press on the [YES] key. 15 Use alkaline batteries for the panel and for the interior and exterior sirens. 16 The ITRA110/600 and DCVA200/600/700 (devices with pet immune) should never be placed in stairs, or near stairs. (Risk of untimely triggerings). 3. Installation and programming Open the packaging box and take out the cardboard divider which serves as a gauge.
3. Installation and programming Display of the keypad Actions and commentaries KEYPAD 1 RECORDED < - LANGUAGE - > ENGLISH Verify the range : A regular flashing or a value of 2/5 or better indicates a sufficient RF radio. RADIO RANGE TEST ? RADIO RANGE x/9 to select the language. Wait for 10s in order to obtain the first stable value RADIO RANGE 9/9 In order to stop the test.
3. Installation and programming Display of the keypad ACCOUNT NUMBER : Keypad Programming Actions and commentaries Enter the Transmittor code + PERIODIC TEST PERIODIC TEST : 24 HOURS to change the period + TEST HOUR : 00 to increase hours + CODE/STATE MODIFICATION ? ENTER YOUR I.D. : , and do the same for minutes. or (to modify the event transmission status,and the on/off controls, refer to Chapter 6.Details on the alarm codes menu, page 10).
3. Installation and programming By default your GPRS panel has parameters of the ORANGE operator. It is necessary to modify the 3 parameters that characterise the connection to another operator (SFR or BOUYGUES, WYLESS, T-MOBILE, ATT...). Remark : GPRS Parameters is Case Sensitive ! (use the M/m key of the keypad to change Capital /Small letters). Be careful : Use arrows to change from one parameter to the other. Press on the [YES] key only when you want to modify a parameter! ORANGE SFR BOUYGUES .....
4. End of installation You have recorded and fix all the devices, record the remote controls, then with the question : Display of the keypad Actions and commentaries ENTERING A NEW DEVICE ? OPERATION COMPLETED ? (Close the cover of the panel) SYSTEM CHECK IN PROGRESS All that remains is to program the user codes, Partial arming modes and eventually the Intercom time (at 180 seconds).
5. How to ... 5.2 Delete the keypad Display of the keypad Actions and commentaries ACCESS LEVEL 3 ACCESS LEVEL LEVEL : 3 => 4 BADGE OR CODE ACCESS LEVEL 4 Use the right arrow to increment the level to 4. Enter the installer code + Use the right arrow to go to the CONFIGURATION menu. CONFIGURATION BADGE OR CODE GENERAL PARAMETERS Enter the installer code + Press the left arrow twice to go to the ZONES AND DEVICES menu.
5. How to ... 5.3 Register again a CMA keypad on an XL panel without opening the cover Activate the touch-sensitive keypad by placing your hand over it. Enter in special mode by pressing for 3 seconds on the and the numerical keypad starts to flash. Type the code 000000 then to switch the XL panel in keypad registration mode. On the keypad: - Insert the 3 Lithium LS14500 batteries. - Simultaneously press [CLR] and [ESC NO] on the keypad untiil the indiicator light on the panel flashes and then release.
6. Details of the menu : ALARM CODE Signalling events by default (except if you are using pre programming) In all cases, be sure to check that the configuration of your XL system is suitable for your needs. By default are not transmited: By default these events are transmited: INITIALIZATION DEVICE (intrusions) ALERT (button) TAMPER PERIODIC TEST PANEL BATTERIES (low panel batteries) AC POWER (panel power off) PHONELINE FAULT (telephone) DEVICE BATT.
7. Table of GPRS error code correspondances !!! The PIN code of the SIM cards must either be disactivated or be 0000 !!! During the GPRS level test, if there is an error an associated code appears in place of the the GPRS level. Start the test again after first error. GPRS LEVEL : ERROR XXX In case of GPRS error, we recommend you continue installation by recording of detectors and devices and then come back to the GPRS level test.
8.