Installation Instructions

Product Summary
The Keypad CMA601 is designed for use in configuration/
programming and operating with a RSI Video Technologies
security system. The keypad includes the following features:
>
Lithium batteries for long life.
>
2-line, 16-character alphanumeric LCD display
with backlighting.
>
Armed status red LED.
>
Built-in piezo for status and alarm sounds.
>
Dual tamper function provides detection for both wall
and cover tamper.
>
Transmits check-in/status signal every 8 minutes.
Installation Guidelines
For easier installation, programming and RF testing
should be done to check for good communication between
the control panel and all system devices before mounting
system devices. Install the keypad and other devices in the
order of the following steps:
>
Programming/RF Testing - program keypad and
all other devices into the control panel and test
RF communication from each intended device
location to the control panel.
>
Mounting - mount keypad at the tested location.
Programming/RF Testing
The following provides summarized steps for device
programming and testing. For complete details, refer to the
control panel installation manual.
1
Remove bottom screw,
separate base from keypad
and install batteries.
2
Re-attach base to
secure tamper switch.
3
Put control panel
into programming/
configuration mode.
4
On keypad, press and
hold Clr and Esc/No
buttons together for
one second, then release
them. Wait for keypad
display to show KEYPAD
1 RECORDED.
5
Press Yes. The display
shows RADIO RANGE
TEST? Press Yes again.
The detector LED starts
flashing and keypad display
shows RF TEST #/9
6
Press Yes to end radio range test, then press Esc/No.
Note: If this is the first keypad programmed in a new installation,
the keypad display prompts you to enter other system configuration data.
If you are adding the keypad to an existing (operational) system, proceed
to step 9.
8
Repeat steps 1 - 8 for all alphanumeric keypads.
9
When finished, exit configuration mode.
Note: The control panel assigns alphanumeric keypads automatically
to Zone 1 (Entry/Exit Delay).
10
Refer to the users manual of your alarm panel to know how
use this device.