User Manual CONTENT 1. Safety Informations 1.1. General Preventive Measures 1.2. Regulations for equipment that connects to power mains 1.3. Technical warnsigns and explanation 4 5 6 2. Introduction 2.1. About us 2.2. E.SHOW mini TW+ / E.SHOW mini FC 7 7 3. General Product Information 3.1. Scope of delivery 3.2. Control Functions 3.3. Features 8 8 8 4. Installation & Setup 4.1 Physical Installation and Rigging 4.2 Connections 4.2.1.1 AC Power 4.2.2. DMX Connection 4.
User Manual 7. Technical Data / Diagrams 7.1 7.2 7.3 7.4 7.5 7.6 7.7 Technical drawings and measurements IP Rating Technical Data - E.SHOW mini TW+ Technical Data - E.SHOW mini FC DMX-Charts / Color Macro Charts / CCT Chart RDM Templates Firmware Update 32 33 34 36 39 69 72 8. Troubleshooting 72 9.
User Manual 1. SAFETY INFORMATION 1.1. General Preventive Measures 1.1.1. Please read, understand and follow the instructions. 1.1.2. Store the instructions and information in a safe place. Best solution is the ring binder provided by ROXX®. 1.1.3. Follow all safety warnings. Under no circumstances remove safety warnings or other information from the equipment. 1.1.4. Don’t use the equipment for any other intended purpose or manner. 1.1.5. Use only stable and compatible stands and/or brackets.
User Manual 1.1.20. Observe all disposal laws applicable in your country. Especially for the packaging. 1.1.21. Plastic bags are not a toy! Keep away from children! 1.1.22. Please note that changes or modifications which are not approved by the party responsible for compliance will void the user’s authority to operate the device. 1.2 Regulations for equipment that connects to power mains 1.2.1.
User Manual 1.3. Technical warnsigns and explanation In order to prevent the risk of an electric shock, under no circumstances remove the cover/back or open the unit in any way! No user serviceable parts are inside. Service, maintenance and repairs should only be done by qualified service personnel or the manufacturer. Dangerous uninsulated voltage inside the device can cause an electrical shock when opened by unqualified personnel.
User Manual 2. INTRODUCTION 2.1. About us The name ROXX® came easily. Combined with the concentrated knowledge and many years of experience, our three founders, who have been leaving their mark in the event and lighting industry for many years already, came together in 2020 to start this outstanding venture.
User Manual 3. GENERAL PRODUCT INFORMATION 3.1. Scope of delivery 1x E.SHOW mini TW+ / E.SHOW mini FC 1x Power cord with plug (EU country specific, if not ordered differently) 1x Pendant luminaire closing caps We´re offering a wide range of professional accessories (optional). Please see under menu 6 or at our website www.roxxlight.com 3.2. Control Functions • E.SHOW mini TW+: 3CH CCT, 3CH RGB, 6CH RGB, 9CH RGB, 11CH RGB, 14CH RGB, 6CH DIRECT, 12CH DIRECT, 13CH DIRECT, 20CH DIRECT, <3CH HSI, 10CH HSI • E.
User Manual 4. INSTALLATION & SETUP 4.1 Physical Installation and Rigging ROXX E.SHOW mini TW+ / E.SHOW mini FC may be installed in any orientation. For this purpose the product provides several options: Standing: The fixtures yoke with its implemented rubber feet is designed to ensure a secure stand on nearly every plane surface with every possible angle/orientation of the lamp ś head. Please take care that supporting surfaces are loadable and stable.
User Manual Pendant Light*: The sophisticated and attractive design of the ROXX E.SHOW mini TW+ / E.SHOW mini FC makes the luminaire predestinated for the use as a pendant light, e.g. for exhibition booths, galas,… The position of the safety eyelet and the lamp body balancing makes that possible in a perfect way. Dismount the Yoke by turning out the both wing screws completely and detach them together with the Yoke and the scaled plastic parts.
User Manual 4.2.1.1 AC Power The ROXX E.SHOW mini TW+ / E.SHOW mini FC operates on any 100–260 V, 50/60 Hz AC mains power supply with a maximum power consumption of 220W. Connect the fixture to AC power using the supplied cable or a similar one with Neutrik powerCON TRUE1 NAC3FX-W or a compatible type, to ensure the correct ingress protection (IP). For temporary installations, the mains cable must be fitted with a grounded connector intended for exterior use.
User Manual The Fixture is able to send DMX-data received by CRMX or Bluetooth to its physical DMX-Output XLR Connector and hereafter, plugged in by cable, to any DMX-capable unit. For this please enable "Pass to DMX Out" inside Wireless DMX Settings. E.SHOW mini TW+ / E.SHOW mini FC can act as a fully operative CRMX Receiver and be paired to an active wireless transmitter (CRMX) simultanously as being connected to a cabled DMX.
User Manual 4.2.2.2. Wireless Connection 11 CH RGB 11 CH RGB 11 CH 1RGB 11 CH RGB 11 CH RGB 11 CH RGB 1 •DMX Next ( 12 ) 1 • CRMX(RX) DMX Next ( 12 ) 1 • CRMX(TX) DMX Next ( 12 ) 1 • CRMX(RX) DMX Next ( 12 ) 1 • CRMX(TX) DMX Next ( 12 ) 1 Next ( 12 ) • CRMX(RX) DMX CRMX Disabled Operation Mode n.a.
User Manual 4.2.2.2. Wireless Connection ! 11 CH RGB 11 CH RGB 11 CH RGB 11 CH RGB 11 CH RGB 1 • CRMX(RX) DMX Next ( 12 ) 1 • BLE DMX Next ( 12 ) 1 CRMX(TX) • BLE DMX Next ( 12 ) 1 CRMX(TX) BLE DMX Next ( 12 ) 1 Next ( 12 ) CRMX(TX) BLE • DMX CRMX Enabled Operation Mode RX Linked Yes, but no DMX Receive Reset Yes DMX Disconnect BLE (Bluetooth) Disabled CRMX Disabled Operation Mode n.a.
User Manual 5. OPERATION 5.1 Start up* Once the fixture is switched On, the boot process starts and the following information will appear on the display: “Ready to ROXX”, the product name and the current software version. After this process, the fixture is ready for operation, and starts in the previously enabled mode. *Note: During boot process the fan spins up quickly to blow out some possible dust from last use. 5.
User Manual Display Off ESC + Pressing ESC + arrow down simultaneously the display backlight function will set to off and the display will turn off immediately. Once a control is pressed the display backlight will turn on. BLE enabled / disabled ESC + Pressing ESC + Arrow Up simultaneously the Bluetooth will enabled or disabled. Confirm by pressing ENTER, step back by pressing ESC. Manual display flip function* + Use the manual display flip function by pressing arrow up + arrow down simultaneously.
User Manual 5.4 Configuration Home Screen After boot process the fixture is ready for operation and starts in the previously enabled mode. At home screen the following information will appear, depending on the current operating mode: A B C D E F DMX Adress Operating Mode (DMX Mode, Quick Light or Standalone Mode) Next available DMX address depending on the fixtures DMX footprint External Data protocol (CRMX, DMX, BLE).
User Manual 5.4.2 Stand Alone* Press ENTER to access to main menu (level 1). While using the UP / DOWN arrows, please select the menu item “Stand Alone” and confirm by pressing ENTER. In the following sub-menu (level 2), you can now choose between 6 different Stand Alone operating modes (Auto, Editor, Color Macro, Quick Color, Tunable White, User Color) ,Stop Stand Alone, Timer and Color Settings functions while using the UP/Down arrows and confirm by pressing ENTER or jump back by pressing ESC.
User Manual Level 1 Level 2 Menu Stand Alone Mode DMX Mode Stand Alone Slave Settings System Info Stop Stand Alone Auto Editor Color Macro Quick Color Tunable White User Color Timer Color Settings Level 3 Level 4 Auto Stop Program 7-Color Fade 7-Color Jump 15-Color Fade 15-Color Jump…..
User Manual Level 1 Level 2 Menu Level 3 Level 4 Stand Alone Mode DMX Mode Stand Alone Slave Settings System Info Stop Stand Alone Auto Editor Color Macro Quick Color Tunable White User Color Timer Color Settings Level 5 - E.SHOW mini TW+ Program 1 Program 2 Program 3 Dim <0-100> Stop Program Program Scene 1 Scene 2 Scene 3 …max. 24 Scenes Level 5 - E.SHOW mini FC Scene Red Green Blue Amber Lime Cyan Shutter Fade Time (min.) Fade Time (sec.) Wait Time (min.) Wait Time (min.
User Manual To select a color macro please press ENTER to access to main menu (level 1). While using the UP / DOWN arrows select the menu item “Stand Alone” and confirm by pressing ENTER. After please select the item “Color Macro” by using the up/down arrows and press ENTER again. Using UP and DOWN controls, select "Center" or "Halo" and confirm by pressing ENTER again. At level 4 select your desired color preset and confirm with ENTER, adjust the brightness for the color preset between 000-100.
User Manual Quick Color* The standalone mode “Quick Color” allows a direct adjustment of the single LED colors Dimmer and Shutter. Level 1 Level 2 Menu DMX Mode Stand Alone Slave Settings Level 3 | E.SHOW mini TW+ Stand Alone Mode Stop Stand Alone Auto Editor Color Macro Quick Color Tunable White User Color Timer Color Settings Level 3 | E.
User Manual Using UP and DOWN controls to select your desired menu item, confirm by ENTER and adjust the desired value by up and down controls and confirm all entries with ENTER. *Note: Tint values 000 001 - 127 -001 to - 127 = no function/neutral = + green = - green *Note: Using UP/DOWN arrows at homescreen the selected CCT value can be changed in +/- 100K steps. Shutter: Please see detailed explanation for strobe effects inside DMX chart at the end of this manual.
User Manual Timer* Via the internal timer function, all Stand Alone modes except "Auto" and "Editor" can be conveniently faded in and out after the function is enabled in the previously activated standalone mode, without the need for an external controller. Also it remains active even the fixture is switched off and restarted. Simultaneously, the timer function is available via cable as well as via wireless DMX for master & slave operation.
User Manual Level 1 Level 2 Menu DMX Mode Stand Alone Slave Settings System Info Level 3 Stand Alone Mode Stop Stand Alone Auto Editor Color Macro Quick Color Tunable White User Color Timer Color Settings Color Settings Color Calibration RAW 5.4.3 Slave Mode* Slave Mode allows same model fixtures to be controlled by the “Master” fixture via DMX or wireless DMX (CRMX). The “Master” device should run in Stand Alone mode, all “Slave” devices should set to “Slave”.
User Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Description CRMX On=CRMX enabled / Off= CRMX disabled Operating Mode Receive= CRMX module as Receiver Transmit= CRMX module as Transmitter Transmit Link Yes= pair with CRMX devices. CRMX must be activated on all devices and the pairing must be picked up by a transmitter (Receive Reset).
User Manual Dimmer Response Color Calibration LED The LED responds abruptly to it´s DMX values Halogen The LED responds similar to a halogen fixture with soft changes at brightness. Full Calibration Color & CCT Calibration CCT Calibration CCT only (RAW Colors) RGBALC (B.SHOW mini TW+) / RGBL (B.SHOW mini FC) with maximum value of brightnes) RAW Settings RAW Balance Red <0-255> E.SHOW mini TW+ (affects RAW Mode in DMX and Stand Alone Modes "Editor", "Quick Color" and "User Color".
User Manual Main Menu Settings Menu level 2 Factory / User Reset Menu level 3 User Reset List Menu level 4 Menu Level 5 Description DMX Mode B.SHOW mini TW+ 3CH CCT / 3CH RGB / 6CH RGB, 9CH RGB / 11CH RGB / 14CH RGB / 6CH DIRECT / 12CH DIRECT / 13CH DIRECT / 20CH DIRECT / 3CH HSI / 10CH HSI DMX Mode B.SHOW mini FC 3CH CCT / 3CH RGB / 6CH RGB/ 9CH RGB / 11CH RGB / 14CH RGB / 4CH DIRECT / 8CH DIRECT, 11CH DIRECT / 16CH DIRECT / 3CH HS / 10CH HSI CRMX CRMX Operating Mode.
User Manual 5.4.5 System Info Level 1 Menu DMX Mode Stand Alone Slave Settings System Info Main Menu Menu level 2 System Info Menu level 3 Menu level 4 Firmware Version vx.xx Display installed firmware version Serial Number E.SHOW mini TW+: 0112xxxxxxxxx E.SHOW mini FC: 0113xxxxxxxxx RDM UID E.SHOW mini TW+: 0X6a6a0112xxxx E.
User Manual 6. ACCESSORIES 6.1 Lenses Available lenses for ROXX E.SHOW mini TW+ / E.SHOW mini FC with order numbers: Very Narrow Art.: 11409701 Narrow Art.: 11408901 Medium Art.: 11409001 Wide Art.: 11409101 Elliptical Narrow Art.: 11409201 Elliptical Wide Art.: 11409301 Lens matrix E.SHOW mini TW+: Lens Beam / Field Angle Distance 3m/9.8ft 5m/16.4ft 7m/23ft 10m/32.
User Manual 6.2 More accessories Safety Free Accessory Holder Art.: 11909401 Full Anti-Glare Shield Art.: 11909801 8-Way Barndoor Art.: 11909501 Honey Comb Art.: 11909501 Omega Bracket ST Art.
User Manual 7. TECHNICAL DATA / DIAGRAMS 7.1 Technical drawings and measurements - ROXX E.SHOW mini TW+ / E.SHOW mini FC 230.0 mm 237.0 mm 273.0 mm 170.0 mm 208.0 mm 187.0 mm 301.0 mm 168.0 mm 188.
User Manual 7.2 IP Rating ROXX products conform to officially classified IP standard levels. E.SHOW mini TW+ / E.SHOW mini FC is rated to IP65 when using the covers for the housing parts. IP stands for Ingress Protection and IP65, according to classified standard, means shielded against dust and high-pressure jets of water from any side. Ingress Protection 65 Protected against a solid object exceeding 50mm, for example, a hand. 1 1 Protected against vertically falling water drops.
User Manual 7.3 Technical Data - E.SHOW mini TW+ Photometrics LED expected lifetime 50.000 hours Lightsource 1x200W RGBALC Type of optical system reflector + interchangable lens plates LED PWM Frequency selectable 800Hz, 1.200Hz, 2.000Hz, 3.
User Manual 7.3 Technical Data - E.SHOW mini TW+ Temperature range, Start-Up -20° to 50°C Temperature range, Storage -20°C to 80°C Thermal Protection Automatic overtemperature protection Electrical Data AC Power, max 90 – 285V 50/60Hz AC Power, nominal 100 – 240V 50/60Hz Electrical protection Overload protection with automatic recover Max Inrush Current 1,206A Max power consumption 130W Standby Power 5,5W Max power thru @ 100 V 11A Max power thru @ 230 V 11A Power Factor 0.
User Manual 7.3 Technical Data - E.SHOW mini TW+ Installation Mounting point on fixture 1 x two quarter-turn locking points for optional Omega Bracket, centric hole 13mm (1/2"), 2x extra holes for TV Spigot Orientation Any Rigging possibilities Hanging or ceiling / pendant mount (Pendant blind caps included) Safety features rear mount for safety wire Minimum distance from flammable materials 0,3 meters (11,8 inch) 7.3 Technical Data - E.SHOW mini FC Photometrics LED expected lifetime 50.
User Manual 7.3 Technical Data - E.
User Manual 7.3 Technical Data - B.
User Manual 7.4 DMX Charts - B.SHOW mini TW+ 3CH CCT 6CH DIRECT 3CH RGB 12CH DIRECT 6CH RGB 13CH DIRECT 9CH RGB 20CH DIRECT 11CH RGB (default mode) 3CH HSI 14CH RGB 10CH HSI 3 CH CCT MODE (Color Calibration) Function Value Setting 1 Dimmer 000-255 0 - 100% 000 - 004 5600K 005-226 2000K-6500K linear in 20-21K steps 182-182 5600K 226-226 6500K 227-255 6621K-10.
User Manual 9 CH RGB MODE - (Color Calibration) Ch.
User Manual 11 CH RGB Mode (Color Calibration) default mode 1 2 Dimmer Center Shutter 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast 085 - 089 Shutter open 090 - 104 Strobe 3: closing pulse (fast 105 - 109 Shutter open 110 - 124 Strobe 4: random strobe (fast 125 - 129 Shutter open 130 - 144 Strobe 5: random opening pulse (fast 145 - 149 Shutter open 150 - 164 Strobe 6:rand
User Manual 10 11 Color Macro Crossfade (Transition Time between Color Macros) Device Settings (please see remark *1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) 106-214 11s - 119s (1s steps) 215-244 2m - 4m50s (10s steps) 245-255 5m - 15m (1m steps) 000-029 No function 030-034 Linear Dimmer Curve (hold 3s) 035-039 Exponential Dimmer Curve (hold 3s) 040-044 Logarithmic Dimmer Curve (hold 3s) 045-049 S-Curve Dimmer Curve (hold 3s) 050-054 Dimmer Response LED (Hold 1,5s) 0
User Manual 14 CH RGB Mode (Color Calibration) Ch.
User DMX CHART Manual 13 14 Color Macro Crossfade (Transition Time between Color Macros) Device Settings (please see remark *1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) 106-214 11s - 119s (1s steps) 215-244 2m - 4m50s (10s steps) 245-255 5m - 15m (1m steps) 000-029 No function 030-034 Linear Dimmer Curve (hold 3s) 035-039 Exponential Dimmer Curve (hold 3s) 040-044 Logarithmic Dimmer Curve (hold 3s) 045-049 S-Curve Dimmer Curve (hold 3s) 050-054 Dimmer Response LED (Hol
User Manual 12 CH - DIRECT MODE (RAW Balance) Ch. Function Value Setting 1 Red 000-255 0 - 100% 2 Red Fine 000-255 0 - 100% 3 Green 000-255 0 - 100% 4 Green Fine 000-255 0 - 100% 5 Blue 000-255 0 - 100% 6 Blue Fine 000-255 0 - 100% 7 Amber 000-255 0 - 100% 8 Amber Fine 000-255 0 - 100% 9 Lime 000-255 0 - 100% 10 Lime Fine 000-255 0 - 100% 11 Cyan 000-255 0 - 100% 12 Cyan Fine 000-255 0 - 100% 13 CH - DIRECT MODE (RAW Balance) Ch.
User Manual Red 000-255 0 - 100% 4 Green 000-255 0 - 100% 5 Blue 000-255 0 - 100% 6 Amber 000-255 0 - 100% 7 Lime 000-255 0 - 100% 8 Cyan 000-255 0 - 100% 000 - 004 RAW 005-226 2000K-6500K linear in 20-21K steps 182-182 5600K 226-226 6500K 227-255 6621K-10.
User Manual 13 Device Settings (please see remark *1) 145-149 Fan Off (hold 3s) 150-154 Fan High Power (hold 3s) 155-159 No function 160-164 Redshift On (Hold 1,5s) 165-169 Redshift Off (Hold 1,5s) 170-179 No function 180-184 Factory Reset (hold 3s) - except User Reset defaults 185-189 User Reset (hold 3s) - except User Colors 190-255 No function Redshift affects only between 2700-3500K 20 CH - DIRECT MODE (RAW Balance) Ch.
User Manual Amber Fine 000-255 0 - 100% 12 Lime 000-255 0 - 100% 13 Lime Fine 000-255 0 - 100% 14 Cyan 000-255 0 - 100% 15 Cyan Fine 000-255 0 - 100% 000 - 004 RAW 005-226 2000K-6500K linear in 20-21K steps 182-182 5600K 226-226 6500K 227-255 6621K-10.
User DMX CHART Manual 20 Device Settings (please see remark *1) 145-149 Fan Off (hold 3s) 150-154 Fan High Power (hold 3s) 155-159 No function 160-164 Redshift On (Hold 1,5s) 165-169 Redshift Off (Hold 1,5s) 170-179 No function 180-184 Factory Reset (hold 3s) - except User Reset defaults 185-189 User Reset (hold 3s) - except User Colors 190-255 No function Redshift affects only between 2700-3500K 3 CH - HSI MODE (Color Calibration) Ch.
User Manual Hue 000-255 0° (RED) Thru 360° 5 Saturation 000-255 0 - 100% (CTC-->HUE) 000 - 004 5600K 005-226 2000K-6500K linear in 20-21K steps 6 CTC (affects HUE and Saturation) --> CTC no effect if Saturation to 100% 182-182 5600K 226-226 6500K 227-255 6621K-10.000K linear in 120-121K steps 0 No function 001-127 Magenta -> Neutral 128-128 Neutral 129-255 Neutral -> Green 7 Tint (affects CTC, HUE and Saturation).
User Manual 10 Device Settings (please see remark *1) remark *1 175-179 Full Calibration (Colors & CCT / Hold 3s) 180-184 CCT Calibration (CCT only / RAW Colors / Hold 3s) 185-189 Factory Reset (hold 3s) - except User Reset defaults 190-194 User Reset (hold 3s) - except User Colors 195-255 No function After adjustments please set the value back to 000 to avoid any disturbance by endless function call.
User Manual 7.4 DMX Charts - B.SHOW mini TW+ 3CH CCT 4CH DIRECT 3CH RGB 8CH DIRECT 6CH RGB 11CH DIRECT 9CH RGB 16CH DIRECT 11CH RGB (default mode) 3CH HSI 14CH RGB 10CH HSI 3 CH CCT MODE (Color Calibration) Function Value Setting 1 Dimmer 000-255 0 - 100% 000 - 004 5600K 005-226 2000K-6500K linear in 20-21K steps 182-182 5600K 226-226 6500K 227-255 6621K-10.
User Manual 9 CH RGB MODE - Color Calibration Ch.
User Manual 11 CH RGB Mode (Color Calibration) default mode 1 2 Dimmer Shutter 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast 085 - 089 Shutter open 090 - 104 Strobe 3: closing pulse (fast 105 - 109 Shutter open 110 - 124 Strobe 4: random strobe (fast 125 - 129 Shutter open 130 - 144 Strobe 5: random opening pulse (fast 145 - 149 Shutter open 150 - 164 Strobe 6:random clos
User Manual 10 11 Color Macro Crossfade (Transition Time between Color Macros) Device Settings (please see remark *1) 000 - 005 No function 006-105 0,1s - 10s (0,1s steps) 106-214 11s - 119s (1s steps) 215-244 2m - 4m50s (10s steps) 245-255 5m - 15m (1m steps) 000-029 No function 030-034 Linear Dimmer Curve (hold 3s) 035-039 Exponential Dimmer Curve (hold 3s) 040-044 Logarithmic Dimmer Curve (hold 3s) 045-049 S-Curve Dimmer Curve (hold 3s) 050-054 Dimmer Response LED (Hold 1,5s) 0
User Manual 14 CH RGB Mode (Color Calibration) Ch.
User Manual 13 14 Color Macro Crossfade (Transition Time between Color Macros) Device Settings (please see remark *1) 000 - 005 No function 006-105 0,1s - 10s (0,1s steps) 106-214 11s - 119s (1s steps) 215-244 2m - 4m50s (10s steps) 245-255 5m - 15m (1m steps) 000-029 No function 030-034 Linear Dimmer Curve (hold 3s) 035-039 Exponential Dimmer Curve (hold 3s) 040-044 Logarithmic Dimmer Curve (hold 3s) 045-049 S-Curve Dimmer Curve (hold 3s) 050-054 Dimmer Response LED (Hold 1,5s) 0
User Manual 8 CH - DIRECT MODE (RAW Balance) Ch. Function Value Setting 1 Red 000-255 0 - 100% 2 Red Fine 000-255 0 - 100% 3 Green 000-255 0 - 100% 4 Green Fine 000-255 0 - 100% 5 Blue 000-255 0 - 100% 6 Blue Fine 000-255 0 - 100% 7 Lime 000-255 0 - 100% 8 Lime Fine 000-255 0 - 100% 11 CH - DIRECT MODE (RAW Balance) Ch.
User Manual 8 CTC (affects RGBL) Tint (affects CTC and RGBL) 9 Color Macro (override RGBL/CTC) 10 Color Macro Crossfade (Transition Time between Color Macros) 11 Device Settings (please see remark *1) RAW 005-226 2000K-6500K linear in 20-21K steps 182-182 5600K 226-226 6500K 227-255 6621K-10.
User Manual 11 Device Settings (please see remark *1) 130-134 Fan Auto (hold 3s) 135-139 Fan Silent (hold 3s) 140-144 Fan Studio (hold 3s) 145-149 Fan Off (hold 3s) 150-154 Fan High Power (hold 3s) 155-159 No function 160-164 Redshift On (Hold 1,5s) 165-169 Redshift Off (Hold 1,5s) 170-179 No function 180-184 Factory Reset (hold 3s) - except User Reset defaults 185-189 User Reset (hold 3s) - except User Colors 190-255 No function 185-189 User Reset (hold 3s) - except User Colors.
User Manual Green 000-255 0 - 100% 7 Green Fine 000-255 0 - 100% 8 Blue 000-255 0 - 100% 9 Blue Fine 000-255 0 - 100% 10 Lime 000-255 0 - 100% 11 Lime Fine 000-255 0 - 100% 000 - 004 RAW 005-226 2000K-6500K linear in 20-21K steps 182-182 5600K 226-226 6500K 227-255 6621K-10.
User Manual 16 Device Settings (please see remark *1) 105-109 LED Frequency 2000Hz (hold 3s) 110-114 LED Frequency 3600Hz (hold 3s) 115-119 LED Frequency 12kHz (hold 3s) 120-124 LED Frequency 25kHz (hold 3s) 125-129 No function 130-134 Fan Auto (hold 3s) 135-139 Fan Silent (hold 3s) 140-144 Fan Studio (hold 3s) 145-149 Fan Off (hold 3s) 150-154 Fan High Power (hold 3s) 155-159 No function 160-164 Redshift On (Hold 1,5s) 165-169 Redshift Off (Hold 1,5s) 170-179 No function 180-
User DMX CHART Manual 3 Shutter 130 - 144 Strobe 5: random opening pulse (fast 145 - 149 Shutter open 150 - 164 Strobe 6:random closing pulse (fast 165 - 169 Shutter open 170 - 184 Strobe 7: burst pulse (fast 185 - 189 Shutter open 190 - 204 Strobe 8: random burst pulse (fast 205 - 209 Shutter open 210 - 224 Strobe 9:sine wave (fast 225 - 229 Shutter open 230 - 244 Strobe 10: burst (fast 245 - 255 Shutter open slow) slow) slow) slow) slow) slow) Hue 000-255 0° (RED) Thru 3
User Manual 10 Device Settings (please see remark *1) remark *1 120-124 LED Frequency 25kHz (hold 3s) 125-129 No function 130-134 Fan Auto (hold 3s) 135-139 Fan Silent (hold 3s) 140-144 Fan Studio (hold 3s) 145-149 Fan Off (hold 3s) 150-154 Fan High Power (hold 3s) 155-159 No function 160-164 Redshift On (Hold 1,5s) 165-169 Redshift Off (Hold 1,5s) 170-174 No function 175-179 Full Calibration (Colors & CCT / Hold 3s) 180-184 CCT Calibration (CCT only / RAW Colors / Hold 3s) 185
User Manual 7.
User Manual 7.
7.000 6.500 6.000 5.500 5.000 2.500 2.000 Color temperature 7.500 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 User Manual 7.5 CTC channel DMX / Color temperature 10.000 9.500 9.000 8.500 8.000 4.500 4.000 3.500 3.
User Manual 7.
User Manual 7.6 RDM Templates* The ROXX Show series features support for various RDM functions. RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional communication between the fixtures and the controller over a standard DMX line. This protocol will allow configuration, status monitoring and management. You will need a RDM controller to get control over the supported parameters. See the tables below for supported RDM features. Label: ROXX E.SHOW mini TW+ / E.
User Manual 0x803A User Calibration- Cyan Set 0x8040 LED Frequency (PWM) Set 1= 800Hz / 2= 1200Hz / 3= 2000Hz / 4= 3600Hz / 5= 12kHz / 6= 25kHz 0x8010 Fan Mode Set 1= Auto / 2= Silent / 3= Studio / 4= Fan Off / 5= Max. Power 0x8032 Redshift Set 0= Off / 1= On 0x801E Factory Reset Yes/No 0= No / 1= Yes 0x801F User Reset Yes/No 0= No / 1= Yes 0x00C0 Firmware Version read n.a. 0x8700 Serial Number Read n.a. Sensor 1 LED Temperature read n.a.
User Manual 0x8040 LED Frequency (PWM) Set 1= 800Hz / 2= 1200Hz / 3= 2000Hz / 4= 3600Hz / 5= 12kHz / 6= 25kHz 0x8010 Fan Mode Set 1= Auto / 2= Silent / 3= Studio / 4= Fan Off / 5= Max. Power 0x8032 Redshift Set 0= Off / 1= On 0x801E Factory Reset Yes/No 0= No / 1= Yes 0x801F User Reset Yes/No 0= No / 1= Yes 0x00C0 Firmware Version read n.a. 0x8700 Serial Number Read n.a. Sensor 1 LED Temperature read n.a. 0x0400 Device Power on Time read n.a.
User Manual 7.7 Firmware Update To update E.SHOW mini TW+ / E.SHOW mini FC mini to newest firmware, please use ROXX update box and make sure the fixtures are connected to DC power. Please download update instructions here: https://roxxlight.com/support/ 8. TROUBLESHOOTING Did you try turning the device off and on again? Problem Reason Solution No power. Check cable connections and conform that power is switched on. Fuse defect. Contact your qualified service technician / manufacturer.
User Manual 9. MANUFACTURER´S DECLARATION Manufacturer´s Warranty & Limitations of Liability Please find our warranty conditions and limitations of liability inside our manufacturer´s declaration at www.roxxlight.com/support Requesting Warranty-Service To request warranty service for your product, please contact: ROXX GmbH, Hansestr. 91, 51149 Köln Email: info@roxxlight.com or the ROXX authorized reseller in your country, from where you purchased your product.
User Manual FCC Radiation Exposure Statement: The device has been evaluated to meet general RF exposure requirement. The device can been used in the portable exposure condition with restriction FCC Radiation Exposure Statement: The equipment complies with FCC Radiation exposure limits set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.