Controller Command List

1
Rotel A12 / A14 /A14MKII
RS232 / IP ASCII Controller Command List
The A12 , A14 and A14MKII support an ASCII based RS232 protocol. The RS232
hardware does not support flow control so care needs to be take when sending and
receiving data to avoid packet loss. A14 will also support IP control using the same
command formats.
All commands sent to the attached Rotel device must have a terminating “!” character.
Example Command: power_on!
Note: Do not include
any spaces in the command, and do not include
a carriage return
or line feed after the
command, only the “!” terminating character.
Status information from the attached Rotel product will have a terminating “$” character.
It is up to the sending/receiving control application to properly parse and process the
packets.
Connection Settings
Baud Rate Parity Valid Data Bits Stop Bit Value
Handshaking Data Type
115200 N 8 1 None String
IP Control Settings
The A14 and A14MKII will only accept and respond to IP control commands if the
product is connected to a local network and has a valid IP address.
Commands will be accepted via TCP port 9590, and the unit will send responses back via
the same port. The command and response format is identical to the serial commands.
Communication Protocol
Command and response messages are included on the following pages.
Automatic status update information can be enabled/disabled using the
“rs232_update_on” and “rs232_update_off” commands.
With RS232 update set to ON, any status changes to the unit will be transmitted via
RS232. With RS232 update set to OFF, the unit will not send any feedback unless polled
by the controller.