Installation Manual

AY-x5B Series
MIFARE Classic® EV1 CSN Readers
Installation Manual
1
1. Introduction
The AY-x5B is a series of RFID proximity card readers to be installed for
use with access control systems.
The AY-x5B series reads the card serial number (CSN) from MIFARE
Classic® EV1 credentials (4 UID and 7 UID) and transmits its data to
the access control system using Wiegand 26-Bit output.
Other Wiegand formats and the Clock & Data format are available as
factory configurable options.
Figure 1: AY-x5B Series
AY-M5B AY-H5B AY-L5B AY-K5B
2. Technical Specifications
2.1 Electrical Characteristics
Specifications AY-M5B AY-H5B AY-L5B AY-K5B
Power Supply Type
Linear (recommended)
Operating Voltage
Range
5–16 VDC
Absolute Maximum
(non-operating)
18 VDC
Current @ 12V
Standby: 45 mA
Maximum: 100 mA
Max. Read Range*
6.5 cm
(2.6 in.)
7.0 cm
(2.8 in.)
6.0 cm
(2.4 in.)
LED Control Input
Dry Contact, N.O.
Maximum Cable
Distance to
Controller
18-AWG: 150 m (500 ft)
20-AWG: 90 m (300 ft)
Frequency
13.56 MHz
Bit Rate
106 KHz
* Measured using a Rosslare MIFARE Classic EV1 card or equivalent. Range also
depends on installation environment, reader voltage, and proximity to metal.
2.2 Environmental Characteristics
Specifications AY-M5B AY-H5B AY-L5B AY-K5B
Operating Temp.
Range
-31°C to 63°C (-25°F to 145°F)
Operating
Humidity Range
0 to 95% (non-condensing)
2.3 Physical Characteristics
Model Dimensions
(H x W x D)
Weight
AY-M5B
89 x 89 x 15 mm
(3.5 x 3.5 x 0.6 in.)
120.3 g
(4.2 oz.)
AY-H5B
110 x 75 x 15 mm
(4.3 x 3.0 x 0.6 in.)
119.9 g
(4.2 oz)
AY-L5B
145 x 43 x 20 mm
(5.7 x 1.7 x 0.8 in.)
115.2 g
(4.1 oz)
AY-K5B
80 x 40 x 12.8 mm
(3.2 x 1.6 x 0.5 in.)
75.5 g
(2.7 oz)
3. Installation
Installation of an RFID reader adjacent to metallic surfaces
might alter the reader’s specifications. To diminish this
interference, use a plastic spacer when mounting the reader.
3.1 Installation Kit
The installation kit consists of the following items to be used during
the installation procedure:
Two pan head mounting screws and screw anchors
3.2 Mounting
Before mounting, you should determine the best location for the
reader.
To mount the reader:
1. Drill two holes for mounting the reader on the wall.
2. Insert a screw anchor into each hole.
3. Drill a 10-mm (7/16”) hole for the cable. If mounting on metal,
place a grommet or electrical tape around the edge of the hole.
4. Remove the screw from the bottom of the unit.
5. Remove the reader's snap-off front cover.
6. Insert the unit’s cable wire into the cable hole and wire the unit as
described in Section 3.3. A linear type power supply is
recommended.
7. Align the two holes of the reader with those drilled in the wall and
firmly attach the reader to the wall with two screws (Figure 2).
Figure 2: Inserting Mounting Screws (similar for all models)
8. Relocate the front cover onto the reader.
9. Secure the front cover with the screw at the bottom of the unit.