AY-B9250BT Professional Fingerprint Reader User Manual
Copyright © 2019 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information. No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
AY-B9250BT User Guide Table of Contents Table of Contents .................................................................................................... 3 1. Before Getting Started ................................................................................. 5 1.1. 1.2. 2. 3. Safety Notes ........................................................................................................ 5 Product Details ..................................................................................
AY-B9250BT User Guide 4 3.6.1. ATTEND .................................................................................................... 39 3.6.2. Screen ...................................................................................................... 40 3.6.3. SAVE ........................................................................................................ 43 3.6.4. TIMEOUT.................................................................................................. 44 3.6.5.
AY-B9250BT User Guide 1. Before Getting Started 1.1. Safety Notes Warning Do not operate the terminal with wet hands, and pay attention not to let any liquid such as water enter inside the terminal. - > Otherwise, malfunction or electric shock may be caused. Do not disassemble, repair or remodel the terminal at your disposal. - > Otherwise, it may cause malfunction, electric shock, or a fire. Keep the terminal away from inflammables. - > Otherwise, it may cause a fire.
AY-B9250BT User Guide 1.2.1.
AY-B9250BT User Guide 1.2.2.
AY-B9250BT User Guide 1.2.3. Input / Output 1.2.3.1. Cable & Connector 1.2.3.2.
AY-B9250BT User Guide 22 23 24 25 26 GRAY BROWN WHITE PURPLE BLACK L1C L1NC L1NO L2 GND LOCK1_COM LOCK1_NC LOCK1_NO LOCK2 GND OUT OUT OUT OUT - 27 BLACK PGND Power GND - 28 BLACK PGND Panel GND - Lock1 COM terminal Lock1 NC terminal Lock1 NO terminal Lock2 terminal Ground connection (Lock connecter) Power supply ground connection (Lock power) Panel ground connection (Earth) 1.2.3.3.
AY-B9250BT User Guide 1.3.1. Initial Screen When powering on at first, the screen is displayed as follow. Operation Mode State icon TNA Mode Date and Time 1.3.2. Icons NONE : No use network : LAN line is disconnected. Server connection State : LAN line is connected (only link is connected) : Connected with server : Gate is closed.
AY-B9250BT User Guide F4 ENABLE DISABLE F2 Category choice (ENABLE or DISABLE) 1.3.4.
AY-B9250BT User Guide Waiting for Card Input Waiting for Fingerprint Input Waiting for Admin App registration Upgrading firmware 1.4. LED information during operation LED RED GREEN Operating state Normal Alarm Terminal Normal(alive) Enter menu OFF ON or Flash ON (Maintain during authentication time) OFF OFF ON ON (Maintain during authentication time) OFF Flash at intervals of 5 seconds Always ON Touch in initial screen.
AY-B9250BT User Guide 1.6. Buzzer guide announced during operation Buzzer Sound State Explanation Beep Key touch Card tag Fingerprint touch -Pressing key or reading card -When inputting fingerprint, input has been completed and hands can take off. 2 Beeps Failure If authentication fails or the user's input is wrong Long Beep Waiting for input It shows the state for waiting user’s input such as fingerprint or password. Short Beeps Success Authentication completion success or setting 1.
AY-B9250BT User Guide If your hands are dry, you can blow your breath on the system to operate it more smoothly. For children, too small or unclear fingerprints may be difficult or impossible to use. They need to register a new fingerprint every six months. For seniors, the fingerprint with too many lines may not be registered. It is recommended that you register more than two fingerprints if possible.
AY-B9250BT User Guide 2.2. Diagram 2.2.1. Single Type (Door Lock) Close BLE 2.4G Mobile App Lock control Open T2 Door Lock 2.2.2. Single Type (Lock Controller) Close RS485 BLE 2.4G Open Mobile App T2 Lock Controller 2.2.3.
AY-B9250BT User Guide 2.2.4. Network Type (Door Lock) Close BLE 2.4G Lock Control Mobile App T2 Ethernet Open Door Lock Internet Ethernet Server 2.2.5. Network Type (Lock Controller) Close RS485 BLE 2.
AY-B9250BT User Guide 2.3. Product Specification Category CPU MEMORY Camera LCD Fingerprint Sensor Authentication Method Authentication Speed Fingerprint capacity Log capacity Communication interface Lock Temperature / Humidity Certification Size Spec 32Bit RISC CPU(400MHz) 64M DDR RAM, 32M NOR,128M NAND VGA, F2.8, View angle 61 degree 1.77’’ Color LCD Optical / 500 DPI Fingerprint, RF Card, Mobile Card 1:N < within 1 sec.
AY-B9250BT User Guide 3. Environment Setting 3.1. Checkpoints before Environment Setting 3.1.1. Menu Press F4 long until the menu screen is displayed. It is available to enter the menu without authentication because the manager doesn’t register when shipping the product. 3.1.2. Administration authentication When the administrator is registered, the admin authentication screen is displayed at first as follows.
AY-B9250BT User Guide 3.1.3. How to access the menu without administrator authentication This is the method to enter the Menu in exceptional cases such as losing your administrator card that is registered in the terminal or inability to make a fingerprint authentication because of absence of administrator. ① Power terminal OFF. ② Disassemble device and make case open state. ③ While case opens, make DIP of rear side switch ON state as follows. ON 1 OFF 2 ON ④ Power terminal ON.
AY-B9250BT User Guide 3.1.5. Default Setting MENU MENU MENU MENU MENU MENU > > > > > NETWORK NETWORK NETWORK NETWORK NETWORK Category Default setting USE TN 1 STATIC IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 > NETWORK > USE > SERVER IP:192.168.0.
AY-B9250BT User Guide 3.1.6. Setting guide for Network Configuration 3.1.6.1. Single Type (Door Lock=STRIKE) Menu position MENU>NETWORK> MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE Possible setting NO USE STRIKE/OK N/O or N/C NONE NONE NONE NONE 3.1.6.2.
AY-B9250BT User Guide MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE DEVICE>DOORLOCK>DM0 DEVICE>DOORLOCK>LOCK2>TYPE DEVICE>DOORLOCK>DM1 DEVICE>DOORLOCK>DM2 DEVICE>RS485>TYPE DEVICE>RS485>DEV ID (Use : When only downloading DB) NONE NONE NONE NONE NONE MCP040 Use in 1~7 3.1.6.6.
AY-B9250BT User Guide MENU>NETWORK>USE>SERVER MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE DEVICE>DOORLOCK>DM0 DEVICE>DOORLOCK>LOCK2>TYPE DEVICE>DOORLOCK>DM1 DEVICE>DOORLOCK>DM2 DEVICE>RS485>TYPE DEVICE>RS485>DEV ID GW:192.168.0.1 IP:192.168.0.2 PORT:7332 NONE NONE NONE NONE NONE LC010 0 3.1.6.9.
AY-B9250BT User Guide 24 If login is successful, the screen is displayed as follows. 3.2.3. Set in terminal In order to connect the terminal to the server, set to the network mode and set the information. Move to MENU > NETWORK > USE > TERMINAL and check whether lower information is correct or not. If you have not changed the device network information, it is displayed as follows.
AY-B9250BT User Guide 25 In order to access the server Move to MENU > NETWORK > USE > SERVER and check the lower information correctly sets or not. If you do not change the server network information, it is displayed as follows. 3.2.4. LAN connection in terminal At first, you can see the unregistered state because the terminal is not registered. 3.2.5. Register the terminal in Rosslare Bio9000 Select the unregistered terminal and press Registration button to activate the screen below.
AY-B9250BT User Guide If the registration is successful, the screen is displayed as follow. For more details about Rosslare Bio9000 operation, please refer to the guide document.
AY-B9250BT User Guide 3.3. Menu Configuration The whole menu is composed of seven, and main characteristics are as follows. Menu USER Submenu1 ADD USER Submenu2 Submenu3 USER ADMIN INPUT ID *Authentication Type Card FP MCARD *Authentication Condition OR AND ※ MCARD is OR condition only. AUTO ADD MODIFY NETWORK DELETE DELETE ALL NO USE USE ※ MCARD is not admitted to set up, state check only.
AY-B9250BT User Guide TERMINAL ID STATIC DHCP SERVER OPTION ATTEND STATIC DHCP TYPE AUTO TNA SCREEN LANGUAGE ENGLISH(0) KOREAN(1) INDONESIAN(2) MULTILINGUAL(3) ARABIC(4) SPANISH(5) PORTUGUESE(6) FRENCH(7) RUSSIAN(8) FARSI(9) JAPANESE(10) CHINESE(11) SHOW ID USER LOGO SAVE USER ID LEN LOG SAVE IMAGE SAVE TIMEOUT Date RESULT NET ERROR PING FORM SETTING INT DEVICE FP SENSOR 1:1 LEVEL (1~9) 1:N LEVEL (5~9) LFD LEVEL TERMINAL ID IP Subnet mask Gateway SERVER Port No NONE M1 F1~F2 M2 F1~F4 M3 F
AY-B9250BT User Guide BEEP VOICE BLE TAMPER EXT DEVICE DOOR LOCK AUTH TIME 0~3 0~5 BLE READY NO ALARM ALARM LOCK1 LOCK2 OPEN ALARM TIME DM0 DM1 DM2 RS485 TYPE WIEGAND DEV ID: 0~255 WIRE-INPUT *TYPE Not Use Strike/OK Indication Motor1 Schedule alarm *OPEN TIME 3[1~20sec] * TYPE NONE Fail Indication Motor2 Schedule alarm * OPEN TIME 3[1~20sec] 5[0~20sec] 0: No Alarm 1~20: Alarm NONE Lock Normal Open Lock Normal Close NONE Lock Normal Open Lock Normal Close Not use Normal Open Normal Close Fire N
AY-B9250BT User Guide WIRE-OUTPUT *TYPE NONE WIE26BIT WIE34BIT CUSTOM *SiteCode STATE DB INFO NETWORK OPTION INT DEVICE USER CNT: USER MAX: ADMIN: FP CNT: FP MAX: CARD CNT: CARD MAX: M.CD CNT: LOG CNT: LOG MAX: TID: xxxx NET: YES, MODE:TN NET TYPE: STATIC ENCRYPT: DES CIP/SN/GW--------xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx MAC: xx: xx: xx: xx: xx: xx SIP/PORT--------xxx.xxx.xxx.
AY-B9250BT User Guide EXT DEVICE BLE Name/MAC---XXXXXXX (BLE Name) XXXXXXXXXXXXXXXXX TAMPER:ALARM LOCK1---------------------TYPE: STRIKE/OK OUT: N/O OPEN: 3000ms LOCK2 ------------------TYPE: NONE OUT: N/O OPEN: 3000ms DOOR WARN: 0sec FORCE OPEN:NO I/O PORT VERSION RECOVERY INITIALIZE SELF TEST RS485: LC010 RS485 ID: xxx WIEGAND---------------IN/OUT :34B/34B SITECODE: xxx SEND:USERID LOCK1: HIGH LOCK2: HIGH DM0: HIGH DM1: HIGH DM2: HIGH W0IN: HIGH W1IN: HIGH INSIDE: HIGH TAMPER SW:HIGH HW FW Card
AY-B9250BT User Guide 3.4. USER Menu USER menu has the feature as follows. Category ADD AUTO ADD MODIFY DELETE DELETE ALL Explanation Use to add user and admin with various certification conditions. Use to add Card or Fingerprint user automatically. Use to add certification conditions, card or fingerprint of registered user. Use to delete a registered particular user. Use to delete all registered users. 3.4.1. ADD 3.4.1.1.
AY-B9250BT User Guide ADMIN Available to add and delete user. Available to access menu and modify it. When selecting the administrator, the screen is displayed as follows. 3.4.1.2. AUTH TYPE There are FP (Fingerprint), Card, and MCARD (Mobile card) in the menu. But MCARD can only provide the check state, and do not provide checking or unchecking. For checking or unchecking with MCARD, it is only available via Server and Admin App. There are AND and OR in authentication conditions.
AY-B9250BT User Guide 3.4.1.4. INPUT CARD When you check Card as AUTH TYPE, you need to follow steps as below. If you input CARD on Waiting state, registration completes and INPUT OK screen is displayed. EM CARD ex) Card No.(5byte): 08h 01h 16h 1Dh D6h Card Format Card No. Display Method Standard 02207638 (16001DD6) (3+5)digits Decimal [022(16h)+07638(1DD6h)] SC CARD ex) Card No.(4byte): 52h 9Dh 06h E3h Card Format Card No. Display Method Standard 529D06E3 8digits Hex 3.4.2.
AY-B9250BT User Guide 35 3.4.2.2. AUTO ADD This is the menu when registering the users continuously only by card. After inputting the card, INPUT OK is displayed on the screen. If you want to add the other user, select 2. YES, and register the user. User IDs increases automatically. 3.4.3. MODIFY It is used when modifying the authentication type of the registered user. In authentication type, authentication type (fingerprint, card) and authentication condition (AND, OR) can be changed.
AY-B9250BT User Guide 3.5. NETWORK Menu Network menu has the following features. Category NO USE USE Explanation Network not used AUTH MODE TERMINAL ID TERMINAL SERVER Operation Mode Standalone Explanation This is the operation mode independently without server and communication. The administrator can control all the functions of the terminal. Authentication log is saved in the terminal but is not sent to server.
AY-B9250BT User Guide 37 processing is done in the terminal or the server when user-authentication. It is a valid setting only when using the network. All authentication log is sent to server through the network. AUTH MODE Server/Terminal Explanation Server Terminal After trying to do server authentication at first, terminal authentication is processed. Terminal/Server Terminal Server After trying to do terminal authentication at first, server authentication is processed.
AY-B9250BT User Guide Network setting in the terminal can be set in Static IP and DHCP. STATIC: Set the value as a user wants. DHCP: Allocated flexibly. (It can be operated normally when using the router supporting DHCP.) If STATIC is used, it is used when setting IP, Subnet mark and Gateway address of the terminal. The following is the default setting value. Category Terminal IP SUBNET MASK GATEWAY Default Setting Value 192.168.0.3 255.255.255.0 192.168.0.1 It can set the address value as follows.
AY-B9250BT User Guide Category ATTEND SCREEN SAVE TIMEOUT LOCKING Explanation TYPE AUTO TNA LANGUAGE SHOW ID USER LOGO USER ID LEN DATE LOGO SAVE IMAGE SAVE RESULT NET ERROR PING NO USE / USE 3.6.1. ATTEND TNA related menu is configured. Category TYPE Explanation When Function Key is used in time and attendance option, it is used. AUTO TNA Use to determine whether to remain Function Key or not shown in the default screen. 3.6.1.1. TYPE It is used when setting ATTEND mode.
AY-B9250BT User Guide Mode NONE F1~F2 F1~F4 F1~F49 Function Key F00 F01 F02 F03 F04 F11~F49 Explanation F00 is only displayed in default screen. F1~F2 Function Key is recognized and F01, F02 are displayed in default screen. F1~F4 Function Key is recognized and, F01, F02, F03, F04 are displayed in default screen. F1~F4 Function Key is recognized and F01, F02, F03, F04, F11~F49 are displayed.
AY-B9250BT User Guide 41 default screen. 3.6.2.1. Language It is used to change the voice language and menu text displayed on the screen. Voice guidance is available in English, Korean, Indonesian, Thai, Arabic, Spanish, Portuguese, French, Russian, Farsi, Japanese, and Chinese. Language support for all menu text is in English, Korean, Indonesian, Spanish, Portuguese, French, Japanese and Chinese. Language support for some text is in Farsi, Arabic, Thai and Russian. 3.6.2.2.
AY-B9250BT User Guide Category NO USE Explanation Use basically the provided default image USE Use the customer’s logo image To use the customer’s logo image, you should update the customer’s image through the server first and then the customer’s image is displayed in the default screen. When editing the customer’s image, it should be edited in the red box as the left picture. The full image size is 128 (W) x160 (H) pixel, and the red box image size is 102 (W) x74 (H) pixel.
AY-B9250BT User Guide 3.6.2.5. DATE It is used to select the order of Year, Month and Day displayed in the default screen. YY: Year MM: Month DD: Day Through SETTING, you can set current Year, Month, Day and Time. 3.6.3. SAVE It is the menu including the function related to SAVE. 3.6.3.1. LOG SAVE It is used to set whether to save the authentication log in memory or not. The default setting is YES.
AY-B9250BT User Guide 44 3.6.3.2. IMAGE SAVE It is used to set whether to save the captured photo from camera when authentication successes or fails. The default setting is Fail. 3.6.4. TIMEOUT It is the menu that has the setting related with timeout. 3.6.4.1. RESULT It is used to set the authentication result display how long it keeps for a seconds. The setting range can be set from 0 to 5 seconds. If it set to 0, then don’t display the authentication result. 3.6.4.2.
AY-B9250BT User Guide 45 3.6.4.3. PING It sets the cycle that terminal sets PING command to the server. The setting range is available for 30~255 seconds. 3.6.5. LOCKING Locking mode is the function that it rejects the authentication of all users until the administrator enters the menu and releases the locking mode. The default setting is NO USE. The default screen is displayed as follows when setting to use locking mode.
AY-B9250BT User Guide 3.7. INT DEVICE Menu INT DEVICE menu has the features as follows. Category FP SENSOR BEEP VOICE BLE TAMPER Explanation 1:1 LEVEL 1: N LEVEL LFD LEVEL AUTH TIME Set Beep Sound. Set Voice Sound BLE registration mode Set the alarm when opening terminal case. 3.7.1. FP SENSOR For the fingerprint recognition, it sets for the user registration and authentication about the module installed inside. 3.7.1.1.
AY-B9250BT User Guide 47 3.7.1.2. 1: N LEVEL It is the authentication level used when it tries 1: N fingerprint authentication. 3.7.1.3. LFD LEVEL It sets LFD LEVEL to prevent the duress fingerprint. If setting LFD LEVEL higher and higher, the ability to prevent the input of duress fingerprint produced by rubber, paper, film, and silicon etc. reinforces but too dry fingerprint cannot be input well. Also the authentication speed can be slow. 3.7.1.4.
AY-B9250BT User Guide 48 3.7.2. BEEP It informs key touch, authentication success, and failure as beep and sets the beep level. The beep level is available from 0 to 3. 3.7.3. VOICE It supports the notice such as authentication success/failure and authentication retrial. It sets the authentication level. The voice level is available from 0 to 5. 3.7.4. BLE When registering the terminal in Administrator’s App, this menu is required. By using this menu, it can make the terminal BLE READY.
AY-B9250BT User Guide If selecting 1. NO ALARM, even if disassembling the terminal, the alarm doesn’t sound but icon is displayed. If selecting 2. ALARM, icon displays and the beep sounds in at regular intervals. 3.8. EXT DEVICE Menu EXT DEVICE has the features as follows. Category Explanation DOORLOCK It sets the control device to lock through the internal relay. RS485 It sets the devices using RS485. WIEGAND It sets the device using WIEGAND. 3.8.1.
AY-B9250BT User Guide 3.8.1.2. LOCK1 OPEN TIME It sets the time to give the signal when LOCK 1 sets 2. STRIKE/OK. Strike type means the time from opening to locking the door after authenticating. The default value is 3 seconds and the input range is 1 to 20 seconds. 3.8.1.3. LOCK2 type NONE FAIL IND MOTOR2 When not using When connecting the light to mark authentication failure in Lock 2 When connecting motor lock 3.8.1.4. LOCK2 OPEN TIME If Lock 2 sets FAIL IND, it sets the time to give the signal.
AY-B9250BT User Guide 51 3.8.1.6. DM0 DM0(Door Monitor 0) is the input port and it is used to detect the signal state of door open. 3.8.1.7. DM1 DM1(Door Monitor 1) is the input port and it is used to detect the signal state of lock. 3.8.1.8. DM2 DM2(Door Monitor 2) is the input port and it is used to detect a various of sensor and alarm. For example, if connecting with fire sensor, it should set 4. FIRE N/O or 5. FIRE N/C and it may cause fire alarm and icon in case of fire.
AY-B9250BT User Guide 3.8.2. RS485 It is the setting for the device with RS485 communication to interface with external. 3.8.2.1. TYPE TYPE NONE LC010 LC015 SR100 MCP040 Explanation It doesn’t use RS485. Lock Controller It controls LOCK through the other external module. Lock Controller It controls LOCK through the other external module. FP Dummy Reader When it installs the other FP dummy reader device in external and then operates, it is used. Terminal operates as the dummy reader.
AY-B9250BT User Guide 53 WIEGAND supports each one of Input port and Output port. 3.8.3.1. WIRE-INPUT It is used to set the input type when working with the device connected into WIEGAND input port. Category NONE WIE26BIT WIE34BIT CUSTOM Explanation WIEGAND input port is not used. EM, HID26 Card Module MIFARE Card Modules Use Access Manager program and set Wiegand format. 3.8.3.2. WIRE-OUTPUT Category NONE WIE26BIT WIE34BIT CUSTOM Explanation WIEGAND output port is not used.
AY-B9250BT User Guide 3.8.3.4. SITE CODE It is used to set the value of Site Code that is sent to WIEGAND output port. 3.8.3.5. SEND INFO It is used to select the transmitting data by the output port. SEND INFO USER ID Card Type 26 Bit 34 Bit None E.Parity(1)+ Site Code(8bit) + ID(16bit) + O.Parity(1) E.Parity(1)+ Site Code(8bit) + ID(24bit) + O.Parity(1) 26 Bit 34 Bit E.Parity(1)+ ID(32bit) + O.Parity(1) E.Parity(1) + 24bit Card Number+ O.Parity(1) E.Parity(1) + 32bit Card Number + O.
AY-B9250BT User Guide NETWORK OPTION INT DEVICE EXT DEVICE I/O PORT VERSION The setting information related to network TNA, Screen setting, Saving, Time out, Lock mode Display the setting state related to the internal device. Display the setting state related to the external device. Display the current signal of Input / Output port that interfaces with outside. Display the version of the equipped device in the terminal. 3.9.1.
AY-B9250BT User Guide 3.9.5. EXT DEVICE It displays the setting information related to the external device. 3.9.6. I/O PORT It reflects the current I/O Port state and displays it on the screen. Output Port: LOCK1, LOCK2 Input Port: DM0~DM2, W0IN, W1IN, INSIDE Open, Tamper When the input port shorts GND, the signal modifies from HIGH to LOW. 3.9.7. VERSION It displays the equipped module in the terminal and other version information.
AY-B9250BT User Guide 57 3.10. RECOVERY Menu RECOVERY has the features as follows. Category INITIALIZE Explanation CONFIG LOG DB FACTORY INT DEVICE EXT DEVICE LOG EXPORT USER EXPORT USER IMPORT FW UPDATE REBOOT SELF TEST BACKUP REBOOT 3.10.1. INITIALIZE It is used to initialize CONFIG, LOG DB, and FACTORY in the terminal. 3.10.1.1. CONFIG It is used to initialize the modified setting value in the menu as the default value when shipping from factory.
AY-B9250BT User Guide 3.10.1.3. FACTORY INIT If trying FACTORY INIT, setting data, authentication log data, and user registration information are initialized as setting state when shipping from factory. ★ It should be careful because the current data can be lost when you setting wrong. 3.10.2. SELF TEST It is used when the terminal tests the operation state about internal & external device by itself. 3.10.2.1.
AY-B9250BT User Guide 59 When authentication successes, it repeats and play voice guidance. Card Test As you see below, the screen displays “INPUT CARD” state at first. When recognizing the card, “Success” screen displays and it returns “INPUT CARD” state again. If you want to stop testing, press F2. FP Sensor Test FP Sensor Test is used to test the operation state of FP sensor from terminal. Input your fingerprint twice, if they are same, it shows “Success” screen.
AY-B9250BT User Guide 3.10.2.2. EXT DEVICE It can test the features related to the external device by itself. Category DOORLOCK SENSOR IN Lock1, Lock2 DM0 DM1 DM2 INSIDE OPEN TAMPER Explanation DOORLOCK Test It is used to check the state of LOCK1, LOCK2 OPEN /CLOSE from the terminal. The procedure is as follows. SENSOR IN It is used to check the signal state about the input port. When the port shorts GND, if signal changes LOW, it is normal.
AY-B9250BT User Guide 3.10.3. BACKUP When the saved data from the terminal sends to USB by using UDL device or brings the data from USB memory and then applies it, it is used. It is available only when the UDL module is. UDL is the option module, so it is not basically provided. If you want to get more information about UDL module, please contact customer service. USB memory recommends using SanDisk.(NOTICE: UDL Device is not supported for all USB memory.
AY-B9250BT User Guide 3.10.3.2. USER EXPORT The saved User DB from the terminal saves in USB memory through UDL. It saves as USER.NDB file. or 3.10.3.3. USER INPUT It reads the user DB from USB memory through UDL and adds it in terminal user DB. If inputting user DB in the terminal, all existing user DB are deleted. If you need the existing user DB saved in the terminal, back up first and try to input the user. It opens USER.NDB file in USB memory and brings into the terminal through UDL.
AY-B9250BT User Guide 63 Appendix 1. Glossary Administrator (Admin) - The administrator can access the terminal menu mode. He/she has the authority to add/modify/delete terminal users and to change the operating environment by changing settings. - If there is no registered administrator in the terminal, anybody can access to the terminal menu and change settings. It is recommended that more than one administrator be registered in the terminal.
AY-B9250BT User Guide 64 Appendix 2. Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: - This device may not cause harmful interference. - This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
AY-B9250BT User Guide 65 Appendix 3. Radio Equipment Directive (RED) Rosslare hereby declares that the AY-H6355BT is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU.
AY-B9250BT User Guide 66 Appendix 4. RoHS Directive Under our sole responsibility that the following labeled AY-U9xxBT is tested to conform to the Restriction of Hazardous Substances (RoHS) directive – 2011/65/EU – in electrical and electronic equipment.
AY-B9250BT Asia Pacific, Middle East, Africa Latin America Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 support.apac@rosslaresecurity.com Rosslare Latin America Buenos Aires, Argentina support.la@rosslaresecurity.com China Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86 755 8610 6842 Fax: +86 755 8610 6101 support.cn@rosslaresecurity.com United States and Canada Rosslare Security Products, Inc.