2012 March AYC-E/Q60 Family Vandal Resistant Convertible Reader/Controllers Instruction Manual
Copyright © 2012 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL, RSP Inc. and/or their related companies and/or subsidiaries’ (hereafter:”ROSSLARE”). Only ROSSLARE and its customers have the right to use the information. No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
Table of Contents Table of Contents 1. Introduction .............................................................. 9 1.1 Reader/Controller Types......................................................... 9 1.2 Box Content ....................................................................... 10 1.3 2. 2.1 2.1.1 2.1.2 3. Ancillary Equipment ............................................................ 10 Technical Specifications .......................................... 11 Key Features ............
Table of Contents 5.2.10 Setting the Reader Format ......................................................... 35 5.2.11 Return to Factory Default Settings ............................................. 35 5.2.12 Replacing a Lost Programming Code ......................................... 36 6. Controller Functionality.......................................... 37 6.1 Normal, Secure, and Master Users........................................ 37 6.2 Modes of Operation ....................................
Table of Contents 6.10.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time .............................................................................. 48 6.10.9 Defining the Auxiliary Input and Output .................................... 50 6.10.10 Detailed Reference Guide .......................................................... 52 6.10.11 Setting the Lockout Feature ....................................................... 56 6.10.12 Setting the Backlight Behavior ..
List of Figures List of Figures Figure 1: Drilling & Mounting Template ........................................................ 14 Figure 2: Back Plate ...................................................................................... 16 Figure 2: Controller Application Wiring Diagram .......................................... 18 Figure 3: Auxiliary Output Connection with Internal Power .......................... 19 Figure 4: Auxiliary Output Connection with External Power..........................
List of Tables List of Tables Table 1: Wiring Colors .................................................................................. 17 Table 2: Reader Programming Menu ............................................................ 22 Table 3: Keypad Transmission Format ........................................................... 25 Table 4: Controller Programming Menu ....................................................... 43 Table 5: Quick Reference Guide for Auxiliary Mode Setting ......................
Notice and Disclaimer Notice and Disclaimer This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein. Before attempting to install and/or use the system, the installer and the user must read this manual and become familiar with all safety requirements and operating procedures. The system must not be used for purposes other than those for which it was designed.
Introduction 1. Introduction The AYC-E/Q60 is a Rosslare goPROX & PIN Reader with Genuine HID Technology®, as well as Rosslare's Convertible technology. The AYCE/Q60 series automatically determines whether to function as a reader or as a secured standalone controller. If the unit is connected to a standard access control unit, then it functions as a reader.
Introduction short beeps. If the secured controller is not detected, it is automatically configured as a reader, indicated by one short beep. 1.2 Box Content Before beginning, verify that all of the following is in the box. If anything is missing, please report the discrepancy to your nearest Rosslare office. One AYC-E/Q60 unit Installation kit – includes security Torx screw and security Torx Screw tool Installation and operating instructions 1.
Technical Specifications 2. Technical Specifications Specifications AYC-E/Q60 Electrical Characteristics Power Supply Type Linear type – recommended Operating Voltage Range 5–16 VDC (when used as a controller, provided by the secured series intelligent power supply) Input current standby (12 VDC) 110 mA Input Current Max (16 VDC) 130 mA LED Control Input Dry contact N.O.
Technical Specifications Specifications AYC-E/Q60 Environmental Characteristics Operating Temp. Range -22°F to 150°F (-30°C to 65°C) Operating Humidity 0 to 95% (non-condensing) Outdoor Usage Weather-resistant, meets IP-65, epoxy potted, suitable for indoor and outdoor use Mechanical E: 6.10 x 3 x 0.827 in. (155 x 1.73 x 0.35 mm) Size (Height x Width x Depth) Q: 4.72 x 2.99 x 0.83 in. (120 x 76 x 21 mm) Weight 2.1 E: 0.32 lb (143 g) Q: 1.
Technical Specifications 2.1.1 Reader Programmable keypad transmission format LED control input Programmable Facility code Rosslare PROX card transmission formats: Clock & Data Wiegand 26-Bit Card + PIN HID Prox Card Transmission Format 2.1.
Installation 3. Installation 3.1 Mounting the AYC-E60 To mount the AYC-E60: 1. Select the location to mount the AYC-E/Q60. This location should be at shoulder height. 2. For wall mounting, use the included mounting template as a guide for drilling holes for mounting screws and wiring. For US Gang Box mounting, no drilling is necessary. Figure 1: Drilling & Mounting Template 3. When the unit is used as a reader, route the interface cable from the AYC-E60 to the controller.
Installation 4. When the unit is used as a secured controller, route the interface cable from the AYC-E60 to a Rosslare secured series intelligent power supply. 5. Screw the AYC-E60 to its mounting location. 6. Return the AYC-E60 front cover to the mounted back plate. 7. Secure the front cover by using the supplied security Torx screw in the controller’s installation kit. A Torx security screw tool is provided for use when tightening the security Torx screw. 3.
Installation Figure 2: Back Plate 5. Drill an additional 7/16” (10-mm) hole for the cable. When installing the reader on a metallic surface, cover the inside of the hole with a grommet or electrical tape. 6. Route the reader's cable to the power and access control system. A regulated linear power supply is recommended. 7. Screw the back plate into the surface. Ensure the screws are the size specified on the installation template. 8. Alternatively, the reader can be mounted with any strong epoxy glue: a.
Wiring Instructions 4. Wiring Instructions The unit is supplied with a 22-inch pigtail, having a 6-conductor cable. To connect the unit to the controller, perform the following: Prepare the unit's cable by cutting the cable jacket back 1¼ inches and strip the wire ½ inch. Splice the unit’s pigtail wires to the corresponding controller wires and cover each connection. Refer to Table 1 and to the wiring diagrams provided on the following pages.
Wiring Instructions • The individual wires from the unit are color-coded according the Wiegand standard. • When using a separate Power Supply for the Reader, this Power Supply and that of the Controller must have a common ground. • The Reader’s cable shield wire should preferably be attached to an earth ground, or a signal ground connection at the panel, or power supply end of the cable.
Wiring Instructions Figure 4 shows the auxiliary output connection using internal power. Figure 4: Auxiliary Output Connection with Internal Power Rosslare PS-X25 ZONE INPUT Figure 5 shows the auxiliary output connection using the external power.
Wiring Instructions Figure 6 shows how to wire a reader to an access control panel.
Reader Functionality 5. Reader Functionality The AYC-E/Q60 series can function both as a reader and as a controller. If the unit is connected to standard access controller, it functions as a reader, indicated by one beep immediately after poweron reset. The following explains how the AYC-E/Q60 series functions as a reader. 5.1 Transmit Mode When the AYC-E/Q60 is in Transmit Mode, it is ready to receive data from a presented Proximity Card or an entered PIN code.
Reader Functionality Table 2 shows the names of all the AYC-E/Q60 menus. Default Factory Settings are marked by a "*" sign.
Reader Functionality 5.2.1 Entering Programming Mode To enter Programming mode: 1. Press the # key 4 times. Transmit LED turns off. Mode/Transmit Door/Program Red Program LED turns red. 2. Enter your 4-digit Programming code. If the Programming code is valid, the door LED turns green and the AYC-E/Q60 is in Programming mode. 5.2.2 Door/Program Mode/Transmit Green • The factory 4-digit Programming code is 1234.
Reader Functionality 5.2.3 Selecting Keypad Transmission Format The AYC-E/Q60 has nine different keypad transmission formats to select from. Follow the steps below to select the appropriate keypad transmission format that you wish to use. To select the key pad transmission format: 1. Enter Programming mode. Door/Program Mode/Transmit Green 2. Press “1” to enter Menu 1. The Transmit LED turns red. Door/Program Mode/Transmit Red Green 3.
Reader Functionality 5.2.4 • Only one keypad transmission format can be active at any one time. • When using the keypad transmission format "1 to 8 keys BCD, Clock & Data" (Option 8) an additional input is required to specify the number of keys in the PIN code. Keypad Transmission Format Option Number See Table 3 to determine the Option Number for the Keypad Transmission Format you wish to select.
Reader Functionality 5.2.4.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format) Each key press immediately sends 4 bits with 2 parity bits added – even parity for the first 3 bits and odd parity for the last 3 bits. 0 = 1 1010 0 ="A" in Hexadecimal 1 = 0 0001 0 2 = 0 0010 0 3 = 0 0011 1 4 = 1 0100 1 5 = 1 0101 0 5.2.4.
Reader Functionality 5.2.4.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26Bit This option buffers 4 keys and outputs keypad data with a 3-digit Facility code like a standard 26-bit card output. The Facility code is set in Programming Menu 4 and can be in the range 000 to 255. The factory default setting for the Facility code is 000 (see Section 5.2.8 for more information). The keypad PIN code is 4 digits in length and can range between 0000 and 9999.
Reader Functionality length, the "#" key must be pressed to signify the end of PIN code entry. For keypad PIN codes that are 5 digits in length, on the fifth key press of the 5-digit PIN code, the data is sent across the Wiegand Data lines as binary data in the same format as a 26-bit card. If the "*" key is pressed during PIN code entry or a PIN code greater than 65,535 is entered, the keypad clears the PIN code entry buffer, generates a beep and is ready to receive a new 5-digit keypad PIN code.
Reader Functionality Where: EP = Even parity for first 12 bits OP = Odd parity for last 12 bits A = The first key entered. B = Second key entered C = Third key entered 5.2.4.7 D = Fourth key entered E = Fifth key entered. F = Sixth key entered Option 7: Single Key, 3x4 Matrix Keypad (MD-P64) This unique mode is intended to let the host controller scan the AYCE/Q60 keypad while still keeping the proximity card readers Wiegand 26-Bit or Clock & Data formats active.
Reader Functionality The reader transmits the data when it receives the last key press of the PIN code. The data is sent across the two data output lines as binary data in Clock & Data format. If the "*" key or the "#" key is pressed during PIN code entry, the keypad clears the PIN code entry buffer, generates a beep, and is ready to receive a new keypad PIN code.
Reader Functionality To select the Rosslare PROX Card transmission format: 1. Enter Programming mode. Door/Program Mode/Transmit Green 2. Press “2” to enter Menu 2. The Transmit LED turns red. Door/Program Mode/Transmit Red Green 3.
Reader Functionality The keypad PIN code can be one to five digits in length in the range of 0 to 99,999. When entering a keypad PIN code, the # key must be pressed to signify the end of the PIN entry. When pressing the # key, the data is sent by the Wiegand data lines. If the * key is pressed, the keypad clears the card buffer and the PIN code entry buffer, generates a medium length beep, and is ready to receive a new card.
Reader Functionality 5.2.7 Changing the Programming Code To change the Programming code: 1. Enter Programming mode. Mode/Transmit Door/Program Green 2. Press “3” to enter Menu 3. The Transmit LED turns red. Mode/Transmit Red Door/Program Green 3. Enter the new 4-digit code you wish to set as the Programming code. The system returns to Transmit mode. 5.2.8 You hear three beeps. Mode/Transmit Door/Program Red The Program LED turns off.
Reader Functionality The system returns to Transmit mode. 5.2.9 You hear three beeps. Door/Program Mode/Transmit Red The Program LED turns off. • The Facility code can be in the range of 000 to 255. • The default Facility code is 0. Setting the Backlight Behavior To set the backlight behavior: 1. Enter Programming mode. Door/Program Mode/Transmit Green 2. Press “6” to enter Menu 6. The Transmit LED turns red. Door/Program Mode/Transmit Red Green 3.
Reader Functionality 5.2.10 Setting the Reader Format To set the reader format: 1. Enter Programming mode. Door/Program Mode/Transmit Green 2. Press “6” to enter Menu 6. The Transmit LED turns red. Door/Program Mode/Transmit Red Green 3. Enter the appropriate option number for the Reader Format “61” for Rosslare PROX “62” for HID Prox “63” for Rosslare PROX + HID Prox (default) The system returns to Transmit mode. You hear three beeps. The Program LED turns off. 5.2.
Reader Functionality 3. Enter your 4-digit Programming code. If the Programming code is valid, all memory is erased, you hear three beeps and the controller returns to Normal mode. If the Programming code is invalid, you hear a long beep and the controller returns to Normal mode without erasing the memory of the controller. 5.2.
Controller Functionality 6. Controller Functionality The AYC-E/Q60 series can function both as a reader and as a controller. If the unit is connected to a Rosslare secured series intelligent power supply, it functions as a controller indicated by two beeps immediately after power-on reset. The Lock Strike Output and Request to Exit input are not located on the AYC-E/Q60 unit, eliminating the possibility of unauthorized entry to the restricted area.
Controller Functionality Secure User A Secure User must have a Primary and Secondary code programmed; the two codes must not be the same. The Secure User can gain access when the AYC-E/Q60 is in any of its three modes of operation. In Normal mode, the Secure User must use the Primary code to gain entry. In Secure Mode, the Secure User must present both the Primary and Secondary codes to gain entry. Master User A Master User must have both Primary and Secondary codes programmed with the same code.
Controller Functionality 6.2.3 Secure Mode Mode/Transmit The Mode LED is red. Door/Program Red Only Secure and Master Users can access the premises during the Secured Mode. A Secure User must enter their Primary and Secondary codes to gain entry. After entering their Primary code, the Door LED flashes green for 10 seconds, during which the Secondary code must be entered. A Master User only needs to present the code once to gain entry. 6.3 Changing the Modes of Operation 6.3.
Controller Functionality 2. Press the “#” key to confirm the mode change. The Mode LED turns green. 6.3.3 Mode/Transmit Door/Program Green Changing from Normal Mode to Bypass Mode See Section 6.10.7 to create/modify the Normal/Bypass code. To change from Normal to By pass mode: 1. Enter the 4-digit Normal/Bypass code. The Mode LED flashes orange. Mode/Transmit Door/Program Green Mode/Transmit Door/Program Orange 2. Press the “#” key to confirm the mode change. The Mode LED turns orange. 6.3.
Controller Functionality 6.5 Door Alarms Door alarms can be generated by connecting the Auxiliary Input to a Door Position Switch. Either Door-Forced or Door-Ajar conditions are supported, as well as a configurable delay timer for each alarm type. Only one door-alarm is enabled at any one time. Door alarms may activate auxiliary output and siren depending on the auxiliary settings. 6.
Controller Functionality Fail Secure Operation: From the moment the REX button is pressed, the door is unlocked until the Lock Strike Release Time passes. After this time, the door is locked even if the REX button is not released. Fail Safe Operation: From the moment the REX button is pressed, the door is unlocked until the REX button is released, plus the Lock Strike Release Time. In this case, the Lock Strike Relay only begins its count down once the REX button is released. 6.
Controller Functionality Settings. Table 4 shows the names of all the AYC-E/Q60 menus. It also shows of all the AYC-E/Q60’s default factory codes and settings. Table 4: Controller Programming Menu Menu No.
Controller Functionality 2. Enter your Programming code. The Door LED turns green and the AYC-E/Q60 enters Programming Mode. 6.10.2 Door/Program Mode/Transmit Green • The AYC-E/Q60 must be in Normal mode to enter Programming mode. • The factory four-digit Programming code is 1234. • If a Programming code is not entered within five seconds, the AYC-E/Q60 returns to Normal mode. Exiting Programming Mode To ex it Programming mode: 1. Press the # key twice within 2 seconds. You hear 3 beeps.
Controller Functionality To change the Lock Strike code: 1. Enter Programming mode. 2. Press “1” to enter Menu 1. The Mode LED turns red. Door/Program Mode/Transmit Red Green 3. Enter the new code you wish to set as the Lock Strike code. The system returns to Normal mode. Door/Program Mode/Transmit Green You hear three beeps. 6.10.4 • Lock Strike code does not work in the Secure mode. • Wrong entries return the controller to Normal mode. • Code 0000 erases the Lock Strike code.
Controller Functionality The system returns to Normal mode. Door/Program Mode/Transmit Green You hear three beeps. 6.10.5 • Auxiliary code does not work in the Secure mode. • Wrong entries return the controller to Normal mode. • Code 0000 erases the Auxiliary code. • The factory default 4-digit Auxiliary code is 0852. Changing the Programming Code To change the Programming code: 1. Enter Programming mode. Mode/Transmit Door/Program Green 2. Press “3” to enter Menu 3.
Controller Functionality 6.10.6 Changing the Normal/Secure Code To change the Normal/ Secure code: 1. Enter Programming mode. Door/Program Mode/Transmit Green 2. Press “4” to enter Menu 4. The Mode LED flashes red. Mode/Transmit Door/Program Red Green 3. Enter the new code you wish to set as Normal/Secure code. The system returns to Normal mode. Mode/Transmit Door/Program Green You hear three beeps. 6.10.7 • Code 0000 erases the Normal/Secure code.
Controller Functionality Disable both Bypass code and the door chime. Enter the code 0000. Disable Bypass code and enable the door chime. Enter the code 0001. Enable Bypass code and disable the door chime. Enter any code ending with 0. Enable Bypass code and enable the door chime. Enter a code not ending with 0. The system returns to Normal mode. You hear three beeps. The Door LED turns off. The Mode LED turns green. 6.10.
Controller Functionality 2. Construct a code using the following instructions: First Digit For Fail Secure Operation, the first digit should be “0”. For Fail Safe Operation the first digit should be “1”. Second Digit Siren Time in minutes (1-9, 0-disabled) Third and Fourth Digits Enter the number of seconds (from 1 to 99) that you want the Lock Strike to be released. For example, 0312 means a Fail Secure Operation consisting of a 3-minute siren and a 12-second Lock Strike release time.
Controller Functionality 6.10.9 Defining the Auxiliary Input and Output The default auxiliary setting is 2004. To define the aux iliary input and output: 1. Enter Programming mode. Mode/Transmit Door/Program Green 2. Press “6” to enter Menu 6. The Mode LED flashes green. Mode/Transmit Door/Program Green Green 3.
Controller Functionality Table 5: Quick Reference Guide for Auxiliary Mode Setting Auxiliary Auxiliary Input Mode Function Auxiliary Output Auxiliary Auxiliary Settings Activated by Relay (in seconds) 0 AUX REX Valid code or AUX REX N.O. 01 to 99 Aux. relay release time 00 Aux. relay toggle 1 Normal/Secure switch Valid code N.O. 01 to 99 Aux. relay release time 00 Aux. relay toggle 2 Normal/Secure switch Star button () N.O. 01 to 99 Aux. relay release time 00 Aux.
Controller Functionality 6.10.10 Detailed Reference Guide The following are brief descriptions of each auxiliary mode. To implement the features of each mode, refer to Section 6.10.9. 6.10.10.1 Auxiliary Mode 0 Auxiliary input function: Activates the auxiliary output Auxiliary output activated by: Valid user code, Auxiliary code, Auxiliary input For example, in Auxiliary Mode 0, the controller can function as a two-door controller. The auxiliary relay is to be attached to the lock on the second door.
Controller Functionality the auxiliary relay is to be activated. The auxiliary input can switch the mode of operation of the controller between Normal and Secure modes. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode (during office hours) to Secure mode (after office hours). 6.10.10.
Controller Functionality 6.10.10.6 Auxiliary Mode 5 Auxiliary input function: Door Monitor Auxiliary output activated by: Shunt (explanation below) For example, in Auxiliary Mode 5, the controller is capable of shunting an alarm system. In this mode, the auxiliary input is to be wired to the magnetic contact switch on the door. The auxiliary relay is wired to the alarm system.
Controller Functionality and if the door does not close prior to the end of this period, the controller activates the auxiliary relay. The auxiliary setting defines the door-ajar time. 6.10.10.9 Auxiliary Mode 8 Auxiliary input function: Green LED control Auxiliary output activated by: Valid user code, Auxiliary code For example, in Auxiliary Mode 8, the controller can function as a two-door controller and also provide indicator functionality control.
Controller Functionality 6.10.11 Setting the Lockout Feature If the controller is presented with wrong codes consecutively several times, the unit goes into Lockout mode. When a lockout occurs, the controller keypad and reader are locked so no codes can be entered until the set lockout period expires. During Lockout, Mode LED is off, the door LED flashes red, and the controller beeps every two seconds. The default setting for the Lockout Feature is 4000 (Lockout Disabled).
Controller Functionality 6.10.12 Setting the Backlight Behavior The controller allows you to define the way the units' Backlight works. To set the backlight operation: 1. Enter Programming mode. 2. Door/Program Mode/Transmit Green Press “6” to enter Menu 6. The Mode LED flashes green. Mode/Transmit Door/Program Green Green 3. Enter one of the following codes: “5000” – Backlight Off “5100” – Backlight On (default) “5200” – Backlight Off, activated on any key press for ten seconds.
Controller Functionality 3. Enter one of the following codes: “6100” – Rosslare PROX “6200” – HID Prox “6300” – Rosslare PROX + HID Prox (default) 6.10.14 Enrolling Primary and Secondary Codes Primary codes Primary codes can only be enrolled to an empty user slot, meaning a slot where there is no existing primary code. Primary codes must be unique, meaning one user’s Primary code may not be the same as other user’s Primary code.
Controller Functionality Code Search Method The Code Search Method is mainly used when enrolling a user’s Secondary code and the User Slot code is unknown. The Code Search method only works if a user’s Primary code is already enrolled but the Secondary code is not (see Section 6.10.14.2). 6.10.14.1 Enrolling Primary and Secondary Codes using the Standard Method To enroll primary and secondary codes using the Standard method: 1. Enter Programming mode. 2.
Controller Functionality If the selected slot already has a Primary code but no Secondary code, the Mode LED flashes red, indicating that the controller is ready to accept a Secondary code. If the selected slot already has a Primary and Secondary code, you hear a long beep and the controller returns to Normal mode. Mode/Transmit Door/Program Red Mode/Transmit Orange Door/Program Green 4.
Controller Functionality 6.10.14.2 Enrolling Secondary Codes using the Code Search Method The Code Search feature enables you to quickly enroll a Secondary code to a user who already has a Primary code. To enroll secondary codes using the Code Search method: 1. Enter Programming mode. Door/Program Mode/Transmit Green 2. Press “7” to enter Menu 7. The Mode LED turns orange. Door/Program Mode/Transmit Orange 3. Perform one of the following: a. Enter 000 as the 3-digit user slot number. b.
Controller Functionality 6. Perform one of the following: a. Enter the code to be used as the Secondary code. b. Present your user card. If the Secondary code is valid, the controller beeps three times and returns to Normal mode. If the Secondary code is invalid, the controller sounds a long beep, and the AYC-E/Q60 continues to wait for a valid Secondary code to be entered. 6.10.
Controller Functionality The Mode LED flashes red indicating the controller is waiting for the Programming code to confirm the deletion. Mode/Transmit Door/Program Red Orange If the user slot is empty, you hear a long beep and the AYCE/Q60 returns to Normal mode. 4. Enter your Programming code to confirm the deletion. If the Programming code is valid, three beeps are heard and the controller returns to Normal mode.
Controller Functionality The controller is now waiting for the Primary code of the user you want to delete. 4. Enter the 4-8 digit PIN code of the Primary code belonging to the user you want to delete. The Mode LED flashes red. Mode/Transmit Red Door/Program Orange 5. Enter your Programming code to confirm the deletion. If the Programming code is valid, you hear three beeps and the unit returns to Normal mode. If the Programming code is invalid, you hear a long beep and the unit returns to Normal mode.
Controller Functionality 3. Enter the 3-digit user slot for code assignment. The Mode LED flashes green. Door/Program Mode/Transmit Green Orange 4. Enter the assignment digit for the current user slot: “1” activates the Lock Strike relay only default “2” activates the Auxiliary relay only “3” activates the Lock Strike and Auxiliary relays If the assignment code is valid, the Mode indicator stops flashing. The controller is now waiting for another slot number. 5.
Controller Functionality 5. The Mode LED flashes green. Mode/Transmit Door/Program Green Orange 6. Enter the assignment digit for the current user slot: “1” activates the Lock Strike relay only default “2” activates the Auxiliary relay only “3” activates the Lock Strike and Auxiliary relays If the assignment digit is valid, three beeps are heard and the controller returns to Normal mode.
Controller Functionality If the Programming code is valid, all memory is erased. You hear three beeps and the controller returns to Normal mode. If the Programming code is invalid, you hear a long beep and the controller returns to Normal mode without erasing the memory contents. 6.10.18 Replacing a Lost Programming Code The AYC-E/Q60 must be in Normal mode; otherwise, this does not work. Make sure that the Mode LED is green before proceeding. 1. Remove power from the Power Supply Unit. 2.
Declaration of Conformity A. Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
Limited Warranty B. Limited Warranty ROSSLARE ENTERPRISES LIMITED (ROSSLARE) FIVE-YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. ROSSLARE'S TWO-YEAR LIMITED WARRANTY is subject to the following conditions: WARRANTY Warranty of ROSSLARE'S products extends to the original purchaser (Customer) of the ROSSLARE product and is not transferable. PRODUCTS COVERED BY THIS WARRANTY AND DURATION ROSSLARE ENTERPRISES LTD.
Limited Warranty minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. ROSSLARE will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by ROSSLARE or a ROSSLARE authorized service center.
Limited Warranty LIMITED WARRANTY TERMS This warranty sets forth the full extent of ROSSLARE’S warranty. The terms of this warranty may not be varied by any person, whether or not purporting to represent or act on behalf of ROSSLARE. This limited warranty is provided in lieu of all other warranties. All other warranties expressed or implied, including without limitation, implied warranties of merchantability and fitness for a particular purpose, are specifically excluded.
AYC-E/Q60 Family Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 support.apac@rosslaresecurity.com United States and Canada Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com Latin America Rosslare Latin America Buenos Aires, Argentina support.la@rosslaresecurity.com China Rosslare Electronics (Shenzhen) Ltd.