Long range Multi Reader AY-Z12 Installation Guide May 2009
Table of Contents Table of Contents 1. Introduction...................................................................... 3 2. Technical Specifications .................................................. 5 3. Installation........................................................................ 6 3.1 The Installation Kit................................................... 6 3.2 Installing the AY-Z12 Long Range Reader: ............. 6 4. Wiring Instructions.............................................
Introduction 1. Introduction The AY-Z12 Long-range Reader is an RFID proximity card reader, utilized with access control systems.
Introduction The AY-Z12, while easy to install and set up, must be installed professionally. This product has only one available channel. Pursuant to FCC §15.21 [ 54 FR 17714 , Apr. 25, 1989, as amended at 68 FR 68545 , Dec. 9, 2003], changes or modifications made to equipment, which are not expressly approved by Rosslare Enterprises, Ltd., may void the user's authority to operate the equipment.
Technical Specifications 2. Technical Specifications Electrical Characteristics Power Supply Type Linear type - recommended Operating Voltage Range 10 - 16VDC Absolute Maximum (non-operating) 18VDC Input Current Standby: 280mA Read: 330mA Tamper Output Open collector, active low, max. sink current 30mA Maximum Cable Distance 500 ft (150 meters) to Controller Card Read Distance Weigand 26 output format with a 23.6" (60 cm) maximum read range* Environmental Characteristics Operating Temp.
Installation 3. Installation 3.1 The Installation Kit The Installation kit comprises of the following items that are to be used during the installation procedure: • One Installation Template • Four pan head screws & wall plugs • One L shaped security screw tool • Three Security screws 3.
Installation Figure 2: Removing the Top Cover Figure 2 shows the front view of the AY-Z12 Long-Range Reader. When installing the reader, you must remove the snap-off cover to access the screw holes. The Reader must be mounted with the appropriate screws (not supplied), as described in the template provided.
Installation To Install the Reader: 1. Determine an approximate location for the installation of the Reader. 2. Peel off the back of the self-adhesive installation label template and locate it at the required location. 3. Using the template as a guide, drill the holes (the size of which are indicated in the template) to install the Reader or spacer onto the surface. 4. Drill a 7/16” (10mm) hole for the cable.
Wiring Instructions 4. Wiring Instructions The AY-Z12 Reader is supplied with an 18” pigtail, comprising a 6conductor cable. To connect the Reader to the Controller: 1. Prepare the Reader cable by cutting its jacket back 1¼” and strip the insulation from the wires, ½”. 2. Prepare the Controller cable by cutting its jacket back 1¼” and strip the insulation from the wires, ½”. 3. Splice the Reader’s pigtail wires to the corresponding Controller wires and cover each joint with insulating tape.
Operation Instructions 5. Operation Instructions The Reader should be tested after wiring it to a power supply and the Controller. To test the Reader: 1. Power up the Reader. The LED flashes green on power up (it may flash orange), and the Beeper sounds twice, at which point it begins an auto-calibration procedure, this can take up to two seconds, when the calibration is complete a third beep will sound, thus indicating that the Reader is working properly. The LED returns to its idle state (red). 2.
Limited Warranty Appendix A: Limited Warranty ROSSLARE ENTERPRISES LIMITED S (Rosslare) FIVE YEARS LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's FIVE YEARS LIMITED WARRANTY is subject to the following conditions: Warranty Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable. Products Covered By This Warranty and Duration ROSSLARE ENTERPRISES LTD.
Limited Warranty Exclusions and Limitations ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE.
Technical Support Appendix B: Technical Support Asia Pacific, Middle East, Africa Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com United States and Canada 1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.
0706-0960127+02 www.rosslaresecurity.