Quick Start Guide 00825-0200-4708, Rev DB February 2018 Rosemount™ 708 Wireless Acoustic Transmitter
Quick Start Guide February 2018 NOTICE This guide provides basic guidelines for the Rosemount 708. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installations. Refer to the Rosemount 708 Reference Manual (document number 00809-0100-4708) for more instruction. This guide and the manual are available electronically on www.rosemount.com. Explosions could result in death or serious injury.
Quick Start Guide February 2018 1.0 Overview Figure 1. Rosemount 708 Wireless Acoustic Transmitter D E B C A A. Power module cover — power module is inside device; unscrew cap for access B. Waveguide — acoustic and temperature sensors C. Electronics cover — cover is sealed and cannot be removed D. Stainless steel mounting bands — used to connect the acoustic transmitter to the piping E. Pipe — the acoustic transmitter is installed directly to the pipe 2.0 Wireless considerations 2.
Quick Start Guide February 2018 Figure 2. Antenna Position 3.0 Field Communicator connections The power module needs to be installed in the device for the Field Communicator to interface with the Rosemount 708. This transmitter uses the green power module; order model number 701PGNKF. Field communication with this device requires a HART® protocol-based Field Communicator using the correct 708 DD. Field Communicator connections are located on the power module.
February 2018 Quick Start Guide 5. Ensure the power module cover is fully tightened to prevent moisture ingress. The lip of the polymer power module cover should be in contact with the surface of the polymer enclosure to ensure a proper seal. Do not over tighten. Figure 4. Transmitter Alignment Figure 5. Transmitter Alignment Top View Figure 6.
Quick Start Guide February 2018 3. Tighten each screw to 90 in-lb (10,2 N-m). 4. Locate the Rosemount 708 and high temperature mounting hardware on a horizontal section of the piping as close as possible to the equipment to be monitored. The mounting location should be free of foreign matter and corrosion to ensure good contact between the piping and the mounting hardware. 5. Insert the U-bolt through the standoff mounting hardware. 6. Tighten each bolt to 90 in-lb (10,2 N-m) (see Figure 8). 7.
Quick Start Guide February 2018 Figure 8. Rosemount 708 Acoustic Transmitter with High Temperature Standoff and Fastener Kit 6.86 (174) 1.81 (46) 3.80 (97) A A. For pipe sizes 0.5 to 2.5-in. Dimensions are in inches (millimeters). 4.3 Mounting considerations 1. Mounting bands should be inspected periodically and re-tightened if necessary. Some loosening may occur after initial installation due to thermal expansion/contraction. 2.
February 2018 Quick Start Guide Figure 9. Piping Insulation Side View 1-in. 5.0 Device network configuration In order to communicate with the Smart Wireless Gateway, and ultimately the information system, the transmitter must be configured to communicate with the wireless network. This step is the wireless equivalent of connecting wires from a transmitter to the host system.
Quick Start Guide February 2018 5.1 AMS Device Manager Right click on the acoustic transmitter and select Configure. When the menu opens, select Join Device to Network and follow the method to enter the network ID and join key. 5.2 Field Communicator The network ID and join key may be changed in the wireless device by using the following Fast Key sequence. Set both network ID and join key. Table 1.
Quick Start Guide February 2018 6.2 Smart Wireless Gateway Using the Smart Wireless Gateway’s integrated web interface, navigate to the Explorer page as shown in Figure 11. Locate the device in question and verify all status indicators are good (green). Figure 11. Smart Wireless Gateway Explorer Page 6.3 AMS Suite Wireless Configurator When the device has joined the network, it will appear in the Device Manager as illustrated in Figure 12.
Quick Start Guide February 2018 Note SteamLogic™ software is provided for viewing steam trap status. Refer to the manual on the CD for more information. 6.4 Troubleshooting If the device is not joined to the network after power up, verify the correct configuration of the network ID and join key, and that active advertising has been enabled on the Smart Wireless Gateway. The network ID and join key in the device must match the network ID and join key of the Gateway.
February 2018 Quick Start Guide 6.5 Field Communicator use Note In order to communicate with a Field Communicator, power the Rosemount 708 by connecting the power module. For more information on the power module, refer to the Product Data Sheet (document number 00813-0100-4701). Table 4 includes Fast Key sequences frequently used to interrogate and configure the device. For additional information, refer to the Rosemount 708 Reference Manual (document number 00809-0100-4708). Table 4.
June 2021 Quick Start Guide Product Certifications – 708 Wireless Acoustic Transmitter Rev: 2.4 European Directive Information Telecommunication compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification.
Quick Start Guide June 2021 Markings: IS CL I, DIV 1, GP A, B, C, D T4; CL 1, Zone 0 AEx ia IIC T4; T4(-40°C ≤ Ta ≤ +70°C) when installed per Rosemount drawing 00708-1000; Type 4X Special Conditions for Safe Use (X): 1. The 708 Wireless acoustic Transmitter shall only be used with the 701PGNKF Rosemount Smartpower Battery Pack 2. Potential Electrostatic charging Hazard – See Instructions Canada I6 Canada Intrinsically Safe Certificate: (CSA) 2439890 Standards: CAN/CSA C22.2 No. 0-M91, CAN/CSA C22.2 No.
June 2021 Markings: Ex ia IIC Ga T4, -40 ~ +70°C Special Conditions for Safe Use (X): See certificate for special conditions Japan I4 TIIS Intrinsic Safety Certificate: TC20395 Markings: Ex ia IIC T4 X (–20 ~ +60 °C) Special Conditions for Safe Use (X): See certificate for special conditions EAC – Belarus, Kazakhstan, Russia IM Technical Regulation Customs Union (EAC) Intrinsic Safety Certificate: RU C-US.Gb05.B.
February 2018 Quick Start Guide Figure 15. Rosemount 708 Declaration of Conformity EU Declaration of Conformity No: RMD 1084 Rev. G We, Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 USA declare under our sole responsibility that the product, Rosemount 708 Wireless Acoustic Transmitter manufactured by, Rosemount, Inc.
Quick Start Guide February 2018 EU Declaration of Conformity No: RMD 1084 Rev. G EMC Directive (2014/30/EU) Harmonized Standards: EN 61326-1: 2013 EN 61326-2-3: 2013 Radio Equipment Directive (RED) (2014/53/EU) Harmonized Standards: EN 300 328 V2.1.1 EN 301 489-1 V2.2.0 EN 301 489-17 V3.2.
February 2018 Quick Start Guide EU Declaration of Conformity No: RMD 1084 Rev.
Quick Start Guide February 2018 ਜ਼ᴹChina RoHS㇑᧗⢙䍘䎵䗷ᴰབྷ⎃ᓖ䲀٬Ⲵ䜘Ԧරਧࡇ㺘 Rosemount 708 List of Rosemount 708 Parts with China RoHS Concentration above MCVs ᴹᇣ⢙䍘 䍘 / Hazardous Substances 䫵 Lead (Pb) ⊎ Mercury (Hg) 䭹 Cadmium (Cd) ޝԧ䬜 䬜 Hexavalent Chromium (Cr +6) ཊⓤ㚄 㚄㤟 Polybrominated biphenyls (PBB) ཊⓤ㚄 㚄㤟䟊 Polybrominated diphenyl ethers (PBDE) ⭥ᆀ㓴Ԧ Electronics Assembly X O O O O O Րᝏಘ㓴Ԧ Sensor Assembly X O O O O O 䜘Ԧ〠 Part Name ᵜ㺘Ṭ㌫ᦞSJ/T11364Ⲵ㿴ᇊ㘼ࡦ This table is proposed i
*00825-0200-4708* Quick Start Guide 00825-0200-4708, Rev DB February 2018 Global Headquarters Emerson Automation Solutions 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com North America Regional Office Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.