Product Certifications 00880-0100-4418, Rev AA September 2022 Rosemount™ 3408 Level Transmitter Non-Contacting Radar
Product Certifications 1 September 2022 Product certifications Rev 0.20 1.1 European directive and UKCA regulations information A copy of the EU/UKCA Declaration of Conformity can be found at the end of this document. The most recent revision of the EU/UKCA Declaration of Conformity can be found at Emerson.com/Rosemount. 1.
September 2022 Product Certifications Frequency range 77.25 to 80.96 GHz LPR (Level Probing Radar) equipment are devices for measurement of level in the open air or in a closed space. Valid for ATAP lens antenna (code SCA). Hardware Version Identification Number (HVIN) is 3408L1 or 3408LB1 (without or with Bluetooth). TLPR (Tank Level Probing Radar) equipment are devices for measurement of level in a closed space only (i.
Product Certifications September 2022 3. The installation of the LPR/TLPR device shall be done by trained installers in strict compliance with the manufacturer’s instructions. 4. The use of this device is on a “no-interference, no-protection” basis. That is, the user shall accept operations of high-powered radar in the same frequency band which may interfere with or damage this device.
September 2022 Product Certifications LPR (Level Probing Radar) For a device with ATAP lens antenna (code SCA): • Install at a separation distance of >4 km from Radio Astronomy sites, unless a special authorization has been provided by the responsible National regulatory authority (a list of Radio Astronomy sites may be found at www.craf.eu). • Between 4 km to 40 km around any Radio Astronomy site the LPR antenna height shall not exceed 15 m height above ground.
Product Certifications September 2022 CL l Zone 0 AEx ia IIC T4...T2 Ga CL l Zone 0/1 AEx ib IIC T4...T2 Ga/Gb Zone 20 AEx ia IIIC T20085°C…T200250°C Da Zone 20/21 AEx ib IIIC T20085°C…T200250°C Da/Db -55 °C ≤ Ta ≤ +70°C When installed per Control Drawing D7000006-887 SINGLE SEAL Safety parameter HART® Voltage Ui 30 V Current Ii 133 mA Power Pi 1.0 W Capacitance Ci 4.9 nF Inductance Li 0 Specific Conditions of Use (X): 1.
September 2022 Product Certifications Table 1-2: For Divisions: Temperature class / Maximum surface temperature Ambient temperature range Process temperature range T2 -55 °C ≤ Ta ≤ +63 °C -55 °C to +200 °C T3 -55 °C ≤ Ta ≤ +63 °C -55 °C to +195 °C T4 -55 °C ≤ Ta ≤ +70 °C -55 °C to +130 °C T3 -55 °C ≤ Ta ≤ +60 °C -55 °C to +160 °C T4 -55 °C ≤ Ta ≤ +60 °C -55 °C to +130 °C T5 -55 °C ≤ Ta ≤ +70 °C -55 °C to +95 °C T6 -55 °C ≤ Ta ≤ +70 °C -55 °C to +80 °C Ambient temperature range Pro
Product Certifications Markings September 2022 CL I Zone 2 AEx ec IIC T4…T2 Gc (-55°C ≤ Ta ≤ +70°C) IP65 V≤35V, I≤22.5 mA SINGLE SEAL Specific Conditions of Use (X): 1. The Model 3408 Level Transmitter will not pass the 500Vrms dielectric strength test between the circuits and the earth ground. This must be taken into account during installation. 2. Plastic part of Process Seal Antenna and Non-standard paint options (paint options other than Rosemount Blue) may cause risk from Electrostatic discharge.
September 2022 Markings Product Certifications IS CL I, ll, lll DIV 1, GRPS A-G T4…T2 NI CL I, DIV 2, GRPS A-D T4…T2 S CL Il, lll DIV 2, GRPS E-G T4…T2 Ex ia IIC T4...T2 Ga Ex ib IIC T4...T2 Ga/Gb Ex ia IIIC T20085°C…T200250°C Da Ex ib IIIC T20085°C…T200250°C Da/Db -55 °C ≤ Ta ≤ +70°C When installed per Control Drawing D7000006-887 SINGLE SEAL Safety parameter HART® Voltage Ui 30 V Current Ii 133 mA Power Pi 1.0 W Capacitance Ci 4.9 nF Inductance Li 0 Specific Conditions of Use (X): 1.
Product Certifications September 2022 Table 1-4: For Divisions: Temperature class / Maximum surface temperature Ambient temperature range Process temperature range T2 -55 °C ≤ Ta ≤ +63 °C -55 °C to +200 °C T3 -55 °C ≤ Ta ≤ +63 °C -55 °C to +195 °C T4 -55 °C ≤ Ta ≤ +70 °C -55 °C to +130 °C T3 -55 °C ≤ Ta ≤ +60 °C -55 °C to +160 °C T4 -55 °C ≤ Ta ≤ +60 °C -55 °C to +130 °C T5 -55 °C ≤ Ta ≤ +70 °C -55 °C to +95 °C T6 -55 °C ≤ Ta ≤ +70 °C -55 °C to +80 °C Ambient temperature range Pro
September 2022 Product Certifications Markings CL I Zone 2 Ex ec IIC T4…T2 Gc (-55°C ≤ Ta ≤ +70°C) IP65 V≤35V, I≤22.5 mA SINGLE SEAL Specific Conditions of Use (X): 1. The Model 3408 Level Transmitter will not pass the 500Vrms dielectric strength test between the circuits and the earth ground. This must be taken into account during installation. 2. Plastic part of Process Seal Antenna and Non-standard paint options (paint options other than Rosemount Blue) may cause risk from Electrostatic discharge.
Product Certifications September 2022 -55 °C ≤ Ta ≤ +70°C Safety parameter HART® Voltage Ui 30 V Current Ii 133 mA (Resistively limited) Power Pi 1.0 W Capacitance Ci 4.9 nF Inductance Li 0 Specific Conditions of Use (X): 1. Precautions shall be taken to minimize the risk from electrostatic discharges and propagating brush discharges. Only clean with a damp cloth. 2. The display glass shall be positioned in such a way as to minimize the risk of mechanical impact. 3.
September 2022 Product Certifications Temperature class / Maximum surface temperature Ambient temperature range Process temperature range T2 -55 °C ≤ Ta ≤ +43 °C -55 °C to +200 °C T3 -55 °C ≤ Ta ≤ +45 °C -55 °C to +195 °C T4 -55 °C ≤ Ta ≤ +70 °C -55 °C to +130 °C T250°C -55 °C ≤ Ta ≤ +43 °C -55 °C to +200 °C T200°C -55 °C ≤ Ta ≤ +45 °C -55 °C to +195 °C T135°C -55 °C ≤ Ta ≤ +70 °C -55 °C to +130 °C T100°C -55 °C ≤ Ta ≤ +70 °C -55 °C to +95 °C T85°C -55 °C ≤ Ta ≤ +70 °C -55 °C to +
Product Certifications September 2022 6. The applicable temperature class versus the ambient temperature range and process temperature range of the equipment is as follows: 1.13 Temperature class Ambient temperature range Process temperature range T2 -55 °C ≤ Ta ≤ +43 °C -55 °C to +200 °C T3 -55 °C ≤ Ta ≤ +53 °C -55 °C to +195 °C T4 -55 °C ≤ Ta ≤ +70 °C -55 °C to +130 °C International 1.13.1 I7 IECEx Intrinsic Safety Certificate IECEx DEK 21.
September 2022 Product Certifications 4. The transmitter head shall only be rotated on top of the antenna in the absence of an explosive atmosphere. 5. The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC 60664-1. 6. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP65.
Product Certifications September 2022 Specific Conditions of Use (X): 1. Precautions shall be taken to minimize the risk from electrostatic discharges and propagating brush discharges. Only clean with a damp cloth. 2. The display glass shall be positioned in such a way as to minimize the risk of mechanical impact. 3. The transmitter head shall only be rotated on top of the antenna in the absence of an explosive atmosphere. 4.
September 2022 1.
Product Certifications 18 September 2022 Rosemount 3408 Level Transmitter
September 2022 Product Certifications Product Certifications 19
Product Certifications 20 September 2022 Rosemount 3408 Level Transmitter
September 2022 Product Certifications Product Certifications 21
Product Certifications September 2022 Figure 1-2: D7000007-647 - System Control Drawing (DEKRA) 22 Rosemount 3408 Level Transmitter
September 2022 Product Certifications Product Certifications 23
Product Certifications 24 September 2022 Rosemount 3408 Level Transmitter
September 2022 Product Certifications Product Certifications 25
Product Certifications 26 September 2022 Rosemount 3408 Level Transmitter
September 2022 1.
Product Certifications 28 September 2022 Rosemount 3408 Level Transmitter
September 2022 Product Certifications Product Certifications 29
Product Certifications 1.
September 2022 Product Certifications Product Certifications 31
*00880-0100-4418* Product Certifications 00880-0100-4418, Rev. AA September 2022 For more information: Emerson.com ©2022 Emerson. All rights reserved. Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.