Installation & Assembly

R
P
O
N
(4)
S
Q
ON
ONDIP
1234
I
J
K
screw
joint
nipple
(3)
L
arm
M
screw cap
bulb
glass shade
Cap
socket ring
socket
cap
A
B
C
D
(1)
rod
screw
pin
hanger frame
white wire
black wire
wire Connector
ground wire
screw
E
G
H
(2)
F
pin
screw
centre column
(5)
black black
white white
gray gray
blue blue
junction box
controller
2
3
4
5
6
(6)
hanger frame
washer
screw
canopy
1
cable
screw
CEILING FAN PRIMARY FUNCTION
IONIZER SECONDARY FUNCTION
READ AND SAVE THESE INSTRUCTIONS
CAUTION:
1. BE CERTAIN THAT NO BARE WIRE STRANDS ARE EXPOSED OUTSIDE OF
THE WIRE CONNECTORS
2.DISCONNECT POWER AT MAIN CIRCUIT BREAKER TO PREVENT
POSSIBLE INJURY FROM ELECTRICAL SHOCK.
3.To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount To Outlet Box Marked
(a) And Use Mounting Screws Provided With The Outlet Box.
4. WARNING To Reduce The Risk Of Electric Shock, This Fan Must Be Installed With An
Isolating Wall Control/Switch
5. WARNING" - To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount
To Outlet Box Marked (a) acceptable for Fan Support of 15.9 kg or less,
And Use Mounting Screws Provided With The Outlet Box
ASSEMBLY & INSTALLATION INSTRUCTIONS
Notice:
1.This product contains chemicals known to the State of California to
cause cancer, birth defects and / or other reproductive harm. Thoroughly wash
hands after installing, handling, cleaning, or otherwise touching this product.
2.Before use this product and maintenance, please read carefully this instruction,
and save in order to use in the future.
3.This product suitable for use with solid-state speed controls
4. The installation is to be in accordance with the National Electrical Code,
ANSI/NFPA 70 and local codes.
5.After wired, the ungrounded wire and grounded/grounding wire must be separated in
two side of the outlet box
6.The splices after being made should be turned upward and pushed carefully up into
the outlet box.
7. The removed controller was suitable for ceiling fan used.
8.This unite will be packed completely to shipping.
9.This unite weight 17.5Kg.
Disconnect the power before installation.
Use and Installation:
Remove all fixture components and the parts bag from the carton.
1: Slip the rod (B) with three holes aligning through hanger frame (A), insert the pin (C)
through the hole of the rod (B) and fall into the groove of the half ball tightened with
screw(D).
2: Put the rod (B) into the centre column (E), align the side hole and hanger frame hole
with screw (F). Fill the screw holw with Pin (G).
3:Screw the Joint (J) with the nipple(I) of the fan, tighten with screw(M) to avoid loose.
Fix the arm (L) on the centre column(E) with screw cap(M).
4:Put the shade(O) in the lamp holder(N)- put the cap(P) in, screw with socket ring(O)
Put bulb(R) in, Screw the bottom cap(S) on the Fan. Put bulb(R) in, Screw the
bottom cap(S) on the Fan.
5: Connect main power wire from junction box with the wires of the controller, black
with black, white with white and attach fixture ground wire and ground wire from outlet
box with wire nut. Connect the output wires from controller and fixture wires with wire
connector, colors: black with black, white with white, grey with grey, blue with blue.
6: An additional safety support is provided to prevent the fan from falling. Secure the
safety cable to the ceiling joist with screw and washer,as illustrated in Figure 1.
Thread the screw (4) through washer (3), screw the hanger frame into junction box firmly.
Cover the junction box with canopy (5), fasten the hanger frame (2) with screws (6).
screw
safetg cable
Spring Washer
Flat Washer
safetg screw
pillar
Figure 1