Assembly Manual

1. ASSEMBLY 3. PRODUCT RANGE (cont.)
Please refer to separate Rollease Acmeda System Assembly
Manual for full assembly instructions relevant to the
hardware system being used.
2. BATTERY MANAGEMENT
For battery motors;
Prevent discharging the battery completely for extended
periods, recharge as soon as the battery is discharged
Before first use please charge motor for 6 hours, using the
recommended AC charger
During operation, if battery is low,
the motor will beep 10 times to
prompt the user it needs charging.
CHARGING NOTES
3
.
PRODUCT
RANGE
(co
nt.)
y
The Quick Start Programming Guide is universal for all
Automate Motors including:
Note: Curtain motor does not
Jog but instead LED flashes
Internal Tubular
Large Tubular
0.6 Cord Lift
0.8 Cord Lift
Curtain
Tilt Motor
3. PRODUCT RANGE
P1
P1
Hold P1
P1
Hold P1
P1 GREEN
P1
P1
Internal Tubular
Large Tubular
0.6 Cord Lift
0.8 Cord Lift
Curtain
Tilt Motor
For battery motors ensure the motor is fully charged as
per instructions.
CHARGE 100%
Use a spare remote to individually program each shade.
Then use that remote to group rooms as per the user’s
needs. If you go back and service the installation later
then, that same remote can be used to check the
individual shades.
Do not dispose of in
general waste.
Incorrect installation or use can lead to serious injury and
will void manufacturer’s liability and warranty. It is
important for the safety of persons to follow the enclosed
instructions. Save these instructions for future reference.
This device complies with Part 15 of the FCC Rules /
Innovation, Science and Economic Development Canada’s
licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference.
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
L’émetteur/récepteur exempt de licence contenu dans
le présent appareil est conforme aux CNR d’Innovation,
Sciences et Développement économique Canada
applicables aux appareils radio exempts
de licence.
L’exploitation est autorisée aux deux conditions
suivantes : 1. L’appareil ne doit pas produire de
brouillage; 2. L’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Changes or modifications not expressly approved by the
party responsible for compliance could void the user's
authority to operate the equipment.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful
interference to radio or television reception, which can
be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by
one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
• Do not expose to water,moisture, humid and damp
environments or extreme temperatures.
• Persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and
knowledge, should not be allowed to use this product.
• Use or modification outside the scope of this instruction
manual will void warranty.
• Installation and programming to be performed by a
suitably qualified installer.
• Follow installation instructions.
• For use with motorized shading devices.
• Keep away from children.
• Frequently inspect for improper operation.
Do not use if repair or adjustment is necessary.
• Keep clear when in operation.
• Replace battery with correctly specified type.
WARNING: Important safety instructions to be read
before installation and use.
INSTALLERS REMOTE
Run the fabric up and down several times to ensure fabric
has settled to some extent and re adjust the limits if needed.
SETTLE FABRIC
If pre-programmed: before shipping the motor ensure
the motor is put into sleep mode so it doesn’t activate
during transit.
SLEEP MODE
Prevent users accidently changing the limit;
ensure the remote is locked as your last step of programming.
LOCK REMOTE
Ask the customer the day before to think how shades will be
zoned on the remote. This may save an extra call out.
ZONE / GROUPS
INSTALLER
BEST PRACTICE AND TIPS
DISPOSAL AND RECYCLING
P1 LOCATIONS
SAFETY
CAUTION
INSTALLER
QUICK START PROGRAMMING
This setup wizard should be used for new installation or factory reset motors only.
Individual steps may not work if you haven't followed the wizard from the beginning.
Select a single or multiple channels by
toggling channels as required.
Note the corresponding LED next to each
channel.
ON
REMOTE
STEP 1
SECS
2
BEEP
x
1
JOG
x
2
* Internal Tubular
pictured.
Refer to “P1 Locations”
for specific devices
ON
REMOTE
Within 4 seconds hold the stop button on the
remote for 3 seconds.
The motor will respond with Jog and Beep
Press the P1 button on the motor for
2 Seconds until the motor responds as
below
STEP 2
MOTOR RESPONSE
BEEP
x
3
JOG
x
2
MOTOR RESPONSE
JOG
x
1
MOTOR RESPONSE
Press up or down to check the motor
direction. If correct skip to step 5.
CHECK
DIRECTION
STEP 3
OR
SECS
5
If the shade direction needs to be reversed;
press and hold the up & down arrow together
for 5 seconds until the motor Jogs.
Reversing motor direction using this method is only
possible during initial set-up.
CHANGE
DIRECTION
STEP 4
SET
UPPER LIMIT
Tap the arrow several times or hold down if
needed; press arrow to stop.
Move shade to desired top limit by
pressing the up arrow repeatedly.
Then press and hold up & stop together
for 5 sec to save limit.
STEP 5
SECS5
BEEP
x
3
JOG
x
2
MOTOR RESPONSE
SET
BOTTOM LIMIT
Tap the arrow several times or hold down if
needed; press arrow to stop.
Move shade to desired bottom limit by
pressing the down arrow repeatedly.
Then press and hold down & stop
together for 5 sec to save limit.
STEP 6
SECS5
SECS
6
Repeat steps 1-6 for all motors.
Once complete Press and hold the Lock
button for 6 seconds while looking at the
LED, and hold until solid.
SAVE
YOUR LIMIT
STEP 7
BEEP
x
4
SECS
14
SECS2 SECS6 SECS10 SECS14
To reset all settings in the motor press
and hold the P1 Button for 14 seconds,
you should see 4 independent jogs
followed by 4x Beeps at the end.
* Internal Tubular pictured above.
Refer to “P1 Locations” for specific devices
FACTORY RESET
MOTOR RESET PROCEDURE
MOTOR RESPONSE
Programming
Guide
Automate Motor