R&S®QPS201 Quick Personnel Security Scanner Getting Started (;ÝRV2) 1179343802 Version 02
This manual contains information about the R&S®QPS201 and accesories with the following order numbers: ● R&S®QPS201 (HW 3.30) (order no. 1333.5000K02) ● R&S®QPS201 (HW 3.50) (order no. 1340.0030K02) ● R&S®LPS (order no. 1340.8001.02) © 2021 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29 - 0 Email: info@rohde-schwarz.com Internet: www.rohde-schwarz.com Subject to change – data without tolerance limits is not binding.
R&S®QPS201 Contents Contents 1 Safety Instructions.................................................................................5 2 Regulatory Information..........................................................................8 3 Key Features.........................................................................................10 4 EMI Suppression.................................................................................. 11 5 System Components.................................................
R&S®QPS201 Getting Started 1179.3438.
R&S®QPS201 Safety Instructions 1 Safety Instructions The R&S QPS is manufactured according to the highest technical standards. To use the scanner safely, follow the instructions provided here and throughout the product documentation. Keep the documentation nearby and offer it to other users. Use the scanner only as intended and within its performance limits. The limits are described in the product documentation, such as the data sheet, manuals and this brochure.
R&S®QPS201 Safety Instructions Installing cables A R&S QPS installation consisting of the scanner, operator touchscreen and monitors requires cable connections (power cables, LAN cables etc.). Make sure to secure all cables on the floor and cover them up. Loose cables are a tripping hazard. Tripping on cables can cause physical injuries. Properly covered cables also minimize the risk of cable damage. Choosing the operating site Use the R&S QPS only indoors.
R&S®QPS201 Safety Instructions Meaning of safety labels Safety labels on the product warn against potential risks. Potential hazard Indicates a potential risk like personal injury or product damage. Read the product documentation for more information. Electric hazard Indicates live parts. Risk of electric shock, fire, personal injury or even death. Protective ground terminal Connect this terminal to a grounded external conductor or to protective ground.
R&S®QPS201 Regulatory Information Regulations for the USA 2 Regulatory Information The R&S QPS complies with the following regulations. 2.1 Regulations for Canada This device contains licence-exempt transmitter(s) / receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following three conditions: ● This device may not cause interference.
R&S®QPS201 Regulatory Information Regulations for the USA manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Getting Started 1179.3438.
R&S®QPS201 Key Features 3 Key Features The R&S QPS Quick Personnel Security Scanner is a system that allows the detection of hidden metallic and non-metallic objects that a person might carry in or underneath their clothing. Possible threats like weapons or explosives can be detected and measures taken against them. The objects are recognized by an evaluation of the reflected (backscattered) microwave signal. The microwaves are of very low intensity.
R&S®QPS201 EMI Suppression 4 EMI Suppression Electromagnetic interference (EMI) may affect the measurement results. To suppress generated electromagnetic interference (EMI): ● Use suitable shielded cables of high quality. For example, use double-shielded LAN cables. ● Always terminate open cable ends. ● Note the EMC classification in the data sheet. Getting Started 1179.3438.
R&S®QPS201 System Components 5 System Components The system consists of various parts. ● Two panels that contain the measuring electronics. The first panel (= primary panel) scans the front of a person. The second panel (= secondary panel) scans the back of a person. The primary panel controls the secondary panel, therefore both panels must be connected to each other. The primary panel shows the silhouette of a person. Otherwise both panels are the same.
R&S®QPS201 System Components 1 2 3 4 = = = = Secondary panel Primary panel (with printed avatar on the inside) Rear side of the panel (facing outward) Front side of the panel (facing inward) 1 = Floorplate 2 = Touchscreen monitor Getting Started 1179.3438.
R&S®QPS201 Preparing for Use 6 Preparing for Use Installing the R&S QPS requires experience and must be performed by trained personnel. For a comprehensive description of the initial installation and configuration of the R&S QPS, refer to the installation manual. Once the scanner itself is installed, you can connect the accessories like the operator touchscreen. Connecting devices All required cables are part of the delivery.
R&S®QPS201 Preparing for Use a) Establish a power supply connection between touchscreen and the primary panel. b) Establish a USB connection between touchscreen and primary panel. c) Establish a DisplayPort connection between touchscreen and primary panel. Connecting resolution station monitors ► Optional: Connect the resolution station monitors to the primary or secondary panel (up to four). a) Establish a LAN connection between resolution station monitor and primary panel. Connecting accessories 1.
R&S®QPS201 Preparing for Use 3-Phase Wye Single phase, 2 wire j 120V L1 240V 120V 208V L1 PE PE L2 120V j j = 120° 120V j L2 For the separate protective ground, you need a green/yellow ground wire with a cross section of at least 4 mm2 in addition to the main protective earthing terminal. The ground wire must be connected permanently to the ground terminal on the side of each R&S QPS panel and earth. The ground terminal is located on the power supply.
R&S®QPS201 Preparing for Use The panel is supplied with power. Booting the panel 1. Establish all necessary connections. 2. Supply both panels with power. 3. Press the power button on the side of the primary panel to turn on the complete system. The system boots. When done, the operator touchscreen shows the login screen. 4. Log into the system to operate the scanner. Note: Level 1, 2 and 3 user accounts will be locked after three failed log in attempts.