ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 STEP PROCEDURE DESIRED RESULTS 1.21 Verify that no fault codes are indicated on the monitor in either the "F3" CSDB output word or in the "350" ARINC-429 Maintenance Data Output word. 1.22 If the UUT fails the Mode-S_Only reply rate as specified in Table 1001/Table 34-50-96-99A-009-A01 step 1.1.A at ambient or during temperature test, first verify the DPSK alignment.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 STEP PROCEDURE DESIRED RESULTS 2.6 Repeat steps 2.4 and 2.5 as necessary. 2.7 a. Set the MODE-S Test Set signal strength for -27 dBm. b. Adjust A6R118 on the Video Processor board while monitoring the positive end of A6C67 with the oscilloscope. 2.8 Steps 2.9 through 2.14 are applicable only to the TDR-94Ds that use the 687-0727-005 Receiver-IF/LVPS.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 STEP 2.13 (cont) PROCEDURE DESIRED RESULTS e. Verify that the two recorded amplitudes are with .1 V of each other. If necessary, readjust the higher voltage downward with A7R178 or A7R179 (whichever is applicable) until the two voltages are with .1 V of each other. The difference between the two recorded voltages is 0 ± 0.1 V.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 STEP 2.17 PROCEDURE DESIRED RESULTS a. Set the MODE-S Test Set for a -50 dBm MODE-S ONLY ALL-CALL interrogation signal. b. Inject an interference pulse of 0.80 μs duration at a carrier frequency of 1030 MHz, that is incoherent with the interrogation. Set the amplitude of the interference pulse to -3dB less than the desired signal level. c. Adjust A7C104 for maximum reply efficiency. NOTE: DPSK adjustments are interactive.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 TASK 34-50-96-820-801-A01 6. Reply Pulse Characteristics SUBTASK 34-50-96-820-001-A01 A. ATCRBS Replies (1) Framing Pulses (a) The reply function shall use two framing pulses nominally spaced 20.3 μs apart. (2) Information Pulses (a) The designator of the information pulses and their positions from the first framing pulse shall be: PULSE C1 A1 C2 A2 C4 A4 B1 D1 B2 D2 B4 D4 POSITION (μs) 1.45 2.90 4.35 5.80 7.25 8.70 11.60 13.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SUBTASK 34-50-96-820-004-A01 D. ATCRBS Reply Pulse Spacing Tolerances (1) The pulse spacing tolerances for each pulse (including the last framing pulse) with respect to the first framing pulse of the reply group shall be ±0.05 μs. The pulse spacing tolerance of the SPI pulse with respect to the last framing pulse of the reply group shall be ±0.05 μs. SUBTASK 34-50-96-820-005-A01 E.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 TASK 34-50-96-810-803-A01 7. Non-Procurable Parts Replacements A. Table 1003/Table 34-50-96-99A-011-A01 below lists replacement CPNs for circuit card/assemblies, as well as components used on circuit cards that are no longer procurable. Use all existing stock of the non-procurable part before using its replacement.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SCHEMATIC AND WIRING DIAGRAMS TASK 34-50-96-810-804-A01 1. Introduction A. This section shows the maintenance aid and schematic diagrams for the TDR94/94D ATC/Mode S Transponder. TASK 34-50-96-810-805-A01 2. Modification History A. Table 2001 shows the causes for changes to the TDR-94/94D. This data helps the technician to know the cause for a service bulletin and gives the changes done to the equipment.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SERVICE BULLETIN REASON/DESCRIPTION 16 In aircraft which parallel the CSDB/ARINC429 Control Select and Burst Enable inputs to other systems, removal of transponder power may cause unrequested activation of the function in another system. The dual diode isolation provided by Service Bulletin No. 12 reduces noise margin for the selection circuits.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SERVICE BULLETIN REASON/DESCRIPTION 20 The -004 and -005 versions of the TDR-94D may cause the Change 7 version of non-Rockwell Collins TCAS systems to produce a TCAS flag, or intermittent TCAS flag, when the TCAS is in the Standby mode. This service bulletin installs new software in the TDR-94D that improves the robustness of the TCAS Change 7 data bus and improves compatibility with non-Rockwell Collins TCAS units.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SERVICE BULLETIN REASON/DESCRIPTION 501 This modification converts -004, -005, and -006 status TDR-94/94D units to -007 status units by reprogramming Processor circuit card A5 and replacing one EPROM. The -007 status TDR-94/94D is compliant with European requirements for Elementary and Enhanced Surveillance for SSR Mode S operation.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 TASK 34-50-96-810-806-A01 3. Schematic Changes Page, Maintenance Aid, and Schematic Diagrams SUBTASK 34-50-96-810-006-A01 A. Schematic Changes Page (1) Shown before each maintenance aid diagram is a schematic changes page. The schematic changes page gives a list of the changes made to the schematic diagram.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 identified as A, the second as B, and continues through Y, then to AA, AB, and continues to YY. (Letters I, O, Q, S, X, and Z are not used). (b) Rework includes changes in a unit or a subassembly sent back to Rockwell Collins for repair, or removed from the company's available units. At the time of rework, the unit or subassembly is identified with the revision level mark (letter) of the changes made.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SUBASSEMBLY/ UNITS REVISION LEVEL COLLINS PART NUMBER MAINTENANCE AID DIAGRAM SCHEMATIC DIAGRAM Power Amplifier Circuit Card A2 A 687-0722-006 Figure 2008.1/ GRAPHIC 34-5096-99B-096-A01 Figure 2008.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SUBASSEMBLY/ UNITS REVISION LEVEL COLLINS PART NUMBER MAINTENANCE AID DIAGRAM SCHEMATIC DIAGRAM CPU-I/O Programmed Assembly A5 A 653-3674-008 Figure 2017/ GRAPHIC 34-5096-99B-052-A01 Figure 2019/ GRAPHIC 34-5096-99B-054-A01 CPU-I/O Programmed Assembly A5 A 653-3674-009 Figure 2017/ GRAPHIC 34-5096-99B-052-A01 Figure 2019/ GRAPHIC 34-5096-99B-054-A01 CPU-I/O Programmed Assembly A5 A 653-3674-010 Figure 2017/ GRA
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 SUBASSEMBLY/ UNITS REVISION LEVEL COLLINS PART NUMBER MAINTENANCE AID DIAGRAM SCHEMATIC DIAGRAM CPU-I/O Circuit Card A5A1 (unprogrammed) C 828-2700-003 Figure 2020/ GRAPHIC 34-5096-99B-055-A01 Figure 2021/ GRAPHIC 34-5096-99B-056-A01 CPU-I/O Programmed Assembly A5 - 653-3674-025 Figure 2021.1/ GRAPHIC 34-5096-99B-098-A01 Figure 2021.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING N/A Printed wire board change only. REV A N/A U20 changed from 351-1278-030 (type 2903) to 351-0656-010 (type 2901). Earlier part became obsolete. REV B N/A Data change only. REV C D C29 changed from 184-2551-210 (10 wF) to 913-3670-740 (0.1 wF). Improve start-up time.
34-50-96 Page 2013/2014 May 18/06 High Voltage Power Supply Circuit Card A1 (CPN 687-0721-002), Maintenance Aid Diagram Figure 2001/GRAPHIC 34-50-96-99B-036-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2015/2016 May 18/06 High Voltage Power SupplyCircuit Card A1 (CPN 687-0721-002), Schematic Diagram Figure 2002/GRAPHIC 34-50-96-99B-037-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING N/A Implemented circuit card in TDR-94/94D main chassis assemblies. REV - N/A Added silicone to circuit card to prevent capacitors from moving. REV A N/A Internal documentation change only. REV B N/A Changed CPN for L2 mounting screw. Previous CPN was incorrect.
34-50-96 Page 2019/2020 May 18/06 High Voltage Power Supply Circuit Card A1 (CPN 687-0721-003), Maintenance Aid Diagram Figure 2003/GRAPHIC 34-50-96-99B-038-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2021/2022 May 18/06 High Voltage Power Supply Circuit Card A1 (CPN 687-0721-003), Schematic Diagram Figure 2004/GRAPHIC 34-50-96-99B-039-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING N/A First production. REV B N/A Relocated R302. REV C D (2) Added L201 and L202; deleted W203 and W206 to correct false power monitor indicator. REV D N/A Production assembly change only.
34-50-96 Page 2025/2026 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-003), Maintenance Aid Diagram Figure 2005 (Sheet 1 of 3)/GRAPHIC 34-50-96-99B-040-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2027/2028 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-003), Maintenance Aid Diagram Figure 2005 (Sheet 2 of 3)/GRAPHIC 34-50-96-99B-040-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2029/2030 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-003), Maintenance Aid Diagram Figure 2005 (Sheet 3 of 3)/GRAPHIC 34-50-96-99B-040-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2031/2032 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-003), Schematic Diagram Figure 2006 (Sheet 1 of 2)/GRAPHIC 34-50-96-99B-041-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2033/2034 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-003), Schematic Diagram Figure 2006 (Sheet 2 of 2)/GRAPHIC 34-50-96-99B-041-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING N/A First production. REV A N/A Replaced diodes CR203 thru CR206 with a more robust part. REV B N/A Data error correction. REV C N/A Removed item 3 heatsink compound; it is no longer required. REV D E (1) Changed Q102 from SD1802 to 23A008 to improve production yield.
34-50-96 Page 2037/2038 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-004), Maintenance Aid Diagram Figure 2007 (Sheet 1 of 3)/GRAPHIC 34-50-96-99B-042-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2039/2040 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-004), Maintenance Aid Diagram Figure 2007 (Sheet 2 of 3)/GRAPHIC 34-50-96-99B-042-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2041/2042 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-004), Maintenance Aid Diagram Figure 2007 (Sheet 3 of 3)/GRAPHIC 34-50-96-99B-042-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2043/2044 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-004), Schematic Diagram Figure 2008 (Sheet 1 of 3)/GRAPHIC 34-50-96-99B-043-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2045/2046 May 18/06 Power Amplifier Circuit Card A2 (CPN 687-0722-004), Schematic Diagram Figure 2008 (Sheet 2 of 3)/GRAPHIC 34-50-96-99B-043-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 Power Amplifier Circuit Card A2 (CPN 687-0722-004), Schematic Diagram Figure 2008 (Sheet 3 of 3)/GRAPHIC 34-50-96-99B-043-A01 34-50-96 Page 2047/2048 May 18/06
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING (This sheet will contain maintenance aid and schematic revision data.) Power Amplifier Circuit Card A2 (CPN 687-0722-006), Maintenance Aid and Schematic Changes Table 2006.1/Table 34-50-96-99A-043-A01 34-50-96 Page 2048.1/2048.
34-50-96 Page 2048.3/2048.4 May 20/10 Power Amplifier Circuit Card A2 (CPN 687-0722-006), Maintenance Aid Diagram Figure 2008.
34-50-96 Page 2048.5/2048.6 May 20/10 Power Amplifier Circuit Card A2 (CPN 687-0722-006), Maintenance Aid Diagram Figure 2008.
34-50-96 Page 2048.7/2048.8 May 20/10 Power Amplifier Circuit Card A2 (CPN 687-0722-006), Maintenance Aid Diagram Figure 2008.
34-50-96 Page 2048.9/2048.10 May 20/10 Power Amplifier Circuit Card A2 (CPN 687-0722-006), Schematic Diagram Figure 2008.
34-50-96 Page 2048.11/ 2048.12 May 20/10 Power Amplifier Circuit Card A2 (CPN 687-0722-006), Schematic Diagram Figure 2008.
34-50-96 Page 2048.13/ 2048.14 May 20/10 Power Amplifier Circuit Card A2 (CPN 687-0722-006), Schematic Diagram Figure 2008.
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING A Q210, R245, R244 deleted and U103B added to prevent false low-power diagnostics during self-test. These changes were made before card was released to production.
34-50-96 Page 2051/2052 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-004), Maintenance Aid Diagram Figure 2009 (Sheet 1 of 2)/GRAPHIC 34-50-96-99B-044-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2053/2054 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-004), Maintenance Aid Diagram Figure 2009 (Sheet 2 of 2)/GRAPHIC 34-50-96-99B-044-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2055/2056 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-004), Schematic Diagram Figure 2010 (Sheet 1 of 4)/GRAPHIC 34-50-96-99B-045-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2057/2058 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-004), Schematic Diagram Figure 2010 (Sheet 2 of 4)/GRAPHIC 34-50-96-99B-045-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2059/2060 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-004), Schematic Diagram Figure 2010 (Sheet 3 of 4)/GRAPHIC 34-50-96-99B-045-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2061/2062 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-004), Schematic Diagram Figure 2010 (Sheet 4 of 4)/GRAPHIC 34-50-96-99B-045-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING NA Initial release. REV A NA Documentation change only. REV B C (2) Changed Q106 from IRF540N (non-procurable) to IRF540.
34-50-96 Page 2065/2066 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-005), Maintenance Aid Diagram Figure 2011 (Sheet 1 of 2)/GRAPHIC 34-50-96-99B-046-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2067/2068 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-005), Maintenance Aid Diagram Figure 2011 (Sheet 2 of 2)/GRAPHIC 34-50-96-99B-046-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2069/2070 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-005), Schematic Diagram Figure 2012 (Sheet 1 of 4)/GRAPHIC 34-50-96-99B-047-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2071/2072 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-005), Schematic Diagram Figure 2012 (Sheet 2 of 4)/GRAPHIC 34-50-96-99B-047-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2073/2074 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-005), Schematic Diagram Figure 2012 (Sheet 3 of 4)/GRAPHIC 34-50-96-99B-047-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2075/2076 May 18/06 Modulator Circuit Card A3 (CPN 687-0723-005), Schematic Diagram Figure 2012 (Sheet 4 of 4)/GRAPHIC 34-50-96-99B-047-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING N/A Data changes only. REV A and B N/A Production process change only. REV C D Changed following components to improve VCO stability: R43 from 47.3 to 10 kവ (705-3535-020) R11 from 1.62 to 1 kവ (705-3535-200) R6 from 392 വ to 3.
34-50-96 Page 2079/2080 May 18/06 Synthesizer Circuit Card A4 (CPN 687-0724-002), Maintenance Aid Diagram Figure 2013/GRAPHIC 34-50-96-99B-048-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2081/2082 May 18/06 Synthesizer Circuit Card A4 (CPN 687-0724-002), Schematic Diagram Figure 2014/GRAPHIC 34-50-96-99B-049-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352 MAINTENANCE AID/SCHEMATIC CHANGES REVISION IDENT (SHEET) DESCRIPTION OF REVISION AND CAUSE FOR CHANGE SERVICE EFFECTIVITY BULLETIN MARKING N/A Implemented circuit card into production. REV A N/A Internal documentation changes only. REV B and C N/A Changed CPN of U413. The new U413 uses a different AT90S2313. EEPROM device.
34-50-96 Page 2085/2086 May 18/06 Synthesizer Circuit Card A4 (CPN 687-0724-003), Maintenance Aid Diagram Figure 2015/GRAPHIC 34-50-96-99B-050-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352
34-50-96 Page 2087/2088 May 18/06 Synthesizer Circuit Card A4 (CPN 687-0724-003), Schematic Diagram Figure 2016 (Sheet 1 of 2)/GRAPHIC 34-50-96-99B-051-A01 ROCKWELL COLLINS COMPONENT MAINTENANCE MANUAL with IPL TDR-94, PART NO 622-9352