GPS25-4 Operating Instructions Please Keep Safe for Future Reference Document Version / Status: V3.
GPS25-4 Operating Instructions Contents 1 Revision History .................................................................................................................................................. 2 2 Symbols and What They Mean ........................................................................................................................... 3 3 Warnings ....................................................................................................................................
GPS25-4 Operating Instructions 1 Revision History Date of this revision: 01.07.2019 Revision Number / Date V1.0 / 08/23/2018 V2.0 / 14/03/2019 V3.0 / 01/07/2019 Author Simon Huber Simon Huber Simon Huber © Rosenberger 2018 – www.rosenberger.
GPS25-4 Operating Instructions 2 Symbols and What They Mean You may encounter the following symbols on the device and in these operating instructions. The meanings of these are provided below. These operating instructions contain important information and so must be read with care. Important warning.
GPS25-4 Operating Instructions 3 Warnings This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
GPS25-4 Operating Instructions 4 Safety Information In principle, the device is safe to operate provided that you observe the information in these operating instructions and on the device itself. The inside of the device contains hazardous electrical circuits that can be lethal if touched. The device is only to be opened and/or repaired by authorized personnel. Never open the device and never attempt to carry out any repairs yourself. Instead, please contact your Customer Service team.
GPS25-4 Operating Instructions Only use the spare parts and accessories included with delivery or spare parts and accessories that have been officially approved by us. Using non-approved spare parts and accessories can significantly impair the function of the device and compromise your safety.
GPS25-4 Operating Instructions 5 Device Description and Usage / Installation Instructions The GPS25-4 is a telematics unit that is solely intended for installation on a Bosch Power Tool. Therefore, please also observe the information in the "Safety Information" section. Connecting the Device: Only authorized specialist personnel are permitted to carry out installation work. For this, the Power Tool must be disconnected from the line voltage by pulling out the power plug.
GPS25-4 Operating Instructions GPS25-4 with power cord 1614460101 GPS25-4 with power cord 1614461033 © Rosenberger 2018 – www.rosenberger.
GPS25-4 Operating Instructions To verify that the device is functioning correctly, you have the option of carrying out a visual check. For further details, see "Commissioning". 6 Scope of Delivery After unpacking the device, immediately check that everything is present and in good condition. If an item is missing or damaged, please let us know right away. For details of your Customer Service team, please see the "Service and Maintenance" section.
GPS25-4 Operating Instructions 8 Commissioning The device must NEVER be commissioned by the operator (end customer/nonspecialist). 9 Function of the Device The GPS25-4 device is a telematics unit that is intended for installation on a Bosch Power Tool. The unit functions independently without the need for a specific commissioning process. Whenever the GPS25-4 is connected to the line voltage, the Li-ion battery starts recharging regardless of its current state of charge.
GPS25-4 Operating Instructions 10 Cleaning the Device It is essential to disconnect the device from the line supply before cleaning it. To do this, unplug the supply cable from the power receptacle. Do not immerse the device in water under any circumstances. Only use the cleaning agents approved by the manufacturer. For further details, see the information below. The device does not require cleaning to function correctly. Periodic cleaning at regular intervals is not necessary.
GPS25-4 Operating Instructions 11 Troubleshooting Only authorized specialists are permitted to carry out troubleshooting by identifying and remedying faults.
GPS25-4 Operating Instructions 13 Technical Data Model: FCC-ID: IC: GPS25-4 TXTGPS25-4 909H-GPS254 Line voltage connection: Rated frequency: 110-240V AC 50/60 Hz Battery connector: Charging current at battery connector: 3.0V – 4.2V DC max. 500mA Ambient conditions: temperature: -20°C-60°C Humidity: max. 93+/- 3% Altitude: max. 3000m Device battery: Battery voltage: Battery capacity Li-Ion, ABI-L-18650-1S1P-DR 3.
GPS25-4 Operating Instructions 14 Disposing of the Device The device has been developed and manufactured using high-quality materials and components that can be recycled and reused. As stipulated by Directive WEEE2 2012/19/EU and the German Electrical and Electronic Equipment Act (ElektroG), the device must not be disposed of together with general/household garbage *. Do not dispose of Li-ion batteries via the municipal waste disposal facilities.
GPS25-4 Operating Instructions 16 Open Source Software The Firmware of this product contains Open-Source-Software, which are subjected to the Open Source license terms. The Open Source components can be changed during lifetime. An overview of the used Open Source components and license, if prescribed by law, can be downloaded from the following portal: www.rosenberger.