Renogy ONE M1 VERSION A0 User Manual
Applicability The user manual applies to the following product: z Renogy ONE M1 Disclaimer z Renogy makes no warranty as to the accuracy, sufficiency, or suitability of information in the user manual because continuous product improvements are going to be made. z Renogy assumes no responsibility or liability for losses or damages, whether direct, indirect, consequential, or incidental, which might arise out of the use of information in the user manual.
Table of Contents Important Safety Information .......................................................................................................05 Symbols Used .........................................................................................................................05 General Safety Information .....................................................................................................05 Introduction ..............................................................................
Activation .....................................................................................................................................33 Operation .....................................................................................................................................34 Wi-Fi ........................................................................................................................................34 Binding ..................................................................
Important Safety Information Symbols Used General Safety Information Important Safety Information The user manual provides important installation, operation, and maintenance instructions for Renogy ONE M1. Please read the user manual carefully before installation and operation and save it for future reference. Failure to observe the instructions or precautions in the user manual can result in electrical shock, serious injury, or death, or can damage Renogy ONE M1, potentially rendering it inoperable.
Important Safety Information Symbols Used General Safety Information federal laws and regulations and use recycling channels as required. z In the event of fire, please use fire extinguishers suitable for electrical equipment. z If Renogy ONE is installed improperly on a ship, it may cause damage to the ship’s corrosive agents. Please have Renogy ONE installed by a qualified (ship) electrician. CAUTION z Do not expose Renogy ONE to flammable or harsh chemicals or vapors.
Introduction Introduction Key Features Introduction Introduction Renogy ONE M1 (hereinafter referred as Renogy ONE) is an all-in-one intelligent energy monitor and smart home command center born to revolutionize how you live off the grid. The 4-inch high-definition display reliably visualizes the energy data of each Renogy device through Bluetooth or RS485 connection, enabling a better control of your power systems only at a simple glance.
Package Contents Package Contents Renogy ONE M1 × 1 Quick Guide × 1 12V Power Cable (5m) × 1 M2 Screws × 4 ST2 x 1.2 x 6.
Product Overview Product Overview 1 No. 2 Part 3 4 No.
Product Overview 1 2 3 IN1 OUT1 +- 4 IN2 OUT2 CAN/RS 485 1 No. 10 8 9 Part 5 IN3 6 7 1 OUT3 TYPE-C 10 1 No.
Wiring Diagram Wiring Diagram 12V + Power Supply - + ≤30V Power - Supply IN1 +- OUT1 IN2 OUT2 CAN/RS485 IN3 OUT3 TYPE-C DC Load (≤30V DC, ≤5A) Devices with RV-C or RS485 communication Positive Negative Communication 11
Communication Diagram Renogy ONE Communication Architecture Energy Device Communication Connections Communication Diagram Renogy ONE Communication Architecture Cloud Wi-Fi Cellular Network Motion Sensor Wi-Fi Window & Door Sensor Smart Plug Zigbee Renogy ONE DC Home App Smart Relay Other Smart Accessories Bluetooth/RS485/RV-C Battery Charge Controller DC-DC Battery Charger Inverter To ensure good compatibility, it is recommended to use Renogy's energy devices and smart accessories.
Communication Diagram Renogy ONE Communication Architecture Energy Device Communication Connections Energy Device Communication Connections Bluetooth 1. For devices with a built-in Bluetooth module or an external Bluetooth module (Renogy BT-1 or BT-2): 2.
Communication Diagram Renogy ONE Communication Architecture Energy Device Communication Connections RV-C Communication 1. For REGO devices connected with RV-C daisy chain topology: RV-C Daisy Chain Topology Renogy ONE Device 1 RV-C Communication Cable RV-C Communication Cable RV-C Communication Cable Device 2 Device N 2. For REGO devices connected with RV-C backbone topology: For backbone topology, please contact our customer service through renogy.com/contact-us/.
Preparation Required Tools Inspection Mounting Location Preparation Required Tools Phillips Screwdriver (#1) Phillips Screwdriver (#2) Insulation Tape Skill Saw Inspection Please inspect Renogy ONE for any visible damage including cracks, dents, deformation, and other visible abnormalities before installation. All connector contacts shall be clean, dry, and free of dirt and corrosion. WARNING z Do not use Renogy ONE if it appears to be damaged.
Preparation Required Tools Inspection Mounting Location Mounting Location 1. Tear off the mounting template in the Quick Guide of Renogy ONE. You can also draw a picture according to the size marked in the mounting template. 12V Power Supply 2. Tape the mounting template to the selected mounting location, and measure whether the 12V power cable is long enough to connect Renogy ONE to your DC power supply.
Preparation Required Tools Inspection Mounting Location 3. If you need to extend the auxiliary 12V power cable, cut it at any part of the auxiliary 12V power cable and strip off some of the insulation. NOTE z When extending the 12V power cable, confirm the polarity of the cable before connecting it to the auxiliary one. A reverse polarity contact will result in abnormal operations. The length of the extension cable should not exceed 10 meters (32.8 feet). 4.
Preparation Required Tools Inspection Mounting Location 6. Tear off the mounting template. 7. Remove the base cover of Renogy ONE. UP 8. Put the protruding part of the base cover into the installation hole (in a direction and position as shown in Figure 1.1.7), and use a Phillips screwdriver to fasten the base cover with four M4 mounting screws through the mounting hole. NOTE z That screws are driven in straight into the mounting holes to ensure the base cover perfectly fits into Renogy ONE.
Embedding 12V Power Cable Communication Cables External Load Embedding 12V Power Cable Battery Combiner Box 1. Connect the ring terminals of the 12V power cable to the positive and negative terminals of the DC power supply device, and reserve the connector end of the power cable in the installation hole. + CAUTION z Illustrations in this user manual are based on scenarios where REGO 12V 400Ah Lithium Iron Phosphate Battery and REGO 3 Ports 400A Battery Combiner Box are adopted as power supplies.
Embedding 12V Power Cable Communication Cables External Load RS485 Communication Recommended Accessories Renogy Communication Hub (For Multiple Devices) Communication Cable (RJ45 Ethernet Cable) HUB NOTE z Please use CAT5 and higher category cables. z Ensure that the device supports RS485 communication. z Please select the appropriate communication cable (sold separately) according to the distance between devices. The length of the communication cable should be less than 30 meters (98.4 feet).
Embedding 12V Power Cable Communication Cables External Load 2. Pre-embed the RJ45 connector of the communication cable into the installation hole. 3. If there is only one device, connect the other end of the communication cable to the communication port of the specific device in use. - + UP port 4. If there are multiple devices, connect the devices to Renogy Communication Hub. HUB NOTE z Ensure that Renogy Communication Hub is connected to the power supply.
Embedding 12V Power Cable Communication Cables External Load 5. Connect the other end of the communication cable to the main communication port of Renogy Communication Hub. HUB RV-C Communication Renogy ONE M1 can communicate with other REGO devices and monitoring devices, enabling safe operation, smart control, remote monitoring, and programmable settings. The RV-C communication wiring varies depending on the connection network topology. Both backbone and daisy chain topologies are supported.
Embedding 12V Power Cable Communication Cables External Load Recommended Accessories RJ45 Plug to Bare Wires Drop Cable Drop Plugs Split Joint Pliers NOTE z The lengths of the Drop Cables shall not exceed 6 meters (19.6 feet), and the total length shall not exceed 30 meters (98.4 feet). z Different drop sockets are used on the RV-C bus by different RV manufacturers. Please select the Drop Plugs that match the drop sockets for the inter-device communication connections.
Embedding 12V Power Cable Communication Cables External Load 1 2 345 6 78 43 21 3. The white green CAN_H wire goes to pin 2 and the white orange CAN_L wire goes to pin 3. Leave pin 1 and pin 4 empty. 4. Squeeze the crimp areas of the Drop Plugs with the Split Joint Pliers. 5. Locate the drop tap (not included) on the RV-C bus that is the closest to the Renogy ONE installation location. The drop taps are usually located above the entry door, in the bathroom, or under the bed in the RV.
Embedding 12V Power Cable Communication Cables External Load NOTE z Different drop taps are used on the RV-C bus by different RV manufacturers. This user manual takes the 4-socket drop tap as an example. CAUTION z If unable to locate the drop taps, please contact the RV manufacturer for help. █ Daisy Chain Topology If an RV-C bus is not pre-installed in the RV, please follow the steps below.
Embedding 12V Power Cable Communication Cables External Load 2. Pre-embed the RJ45 connector of the communication cable into the installation hole. 3. Unplug the LP16 Terminator Plug (7Pin) on the first or last REGO device in the communication network. 4. Insert the LP16 Plug (7-Pin) to RJ45 Communication Adapter Cables into the communication ports of other REGO devices.
Embedding 12V Power Cable Communication Cables External Load External Load Renogy ONE comes with 3 relays which can be connected to 3 DC loads (≤30V DC, ≤5A). You can power on/off the loads via Panel Switches on Renogy ONE. For users who do not need external loads, no adapter cable pre-embedding is required.
Embedding 12V Power Cable Communication Cables External Load WARNING z Please ensure that the working current of an external DC load is less than or equal to 5A; otherwise Renogy ONE may be damaged. z Please ensure that the output voltage of the DC power supply for an external DC load is less than or equal to 30V; otherwise Renogy ONE may be damaged. z Make sure the DC power supply is powered off before connection. z Please confirm the polarity of the DC power supply device before connection.
Wiring 12V Power Cable Communication Cables External Load Wiring 12V Power Cable 1. Insert the 12V power cable terminal block into Renogy ONE power port. CAN/RS4 + - IN1 OUT1 IN2 TYPE-C 85 OUT2 IN3 OUT3 2. Power on the DC power supply and check if Renogy ONE automatically turns on with the LCD lighting up. After the test is complete, please power off the power supply.
Wiring 12V Power Cable Communication Cables External Load Communication Cables 1. Connect the preembedded RJ45 connector to the RJ45 port of Renogy ONE. -C PE TY TYPE-C CAN/RS485 + - OUT1 IN1 IN2 OUT2 5 S48 N/R CA IN3 OUT3 External Load CAN/RS485 IN1 OUT1 IN2 OUT2 TYPE-C IN3 OUT3 CH3 +- OUT 3 IN 3 OUT 2 IN 2 OUT 1 IN 1 CH2 1. Ensure that the DC power supply cable and the cable that is connected to the positive pole of the load are connected to the same group of terminals.
Wiring 12V Power Cable Communication Cables External Load +CAN/ IN1 RS48 OUT 1 IN2 5 TYPE -C OUT 2 IN3 OUT 3 DC load (≤30V DC, ≤5A) OUT + 3. Insert the reserved adapter cable connecting to the positive terminal of the load into the Renogy ONE output terminal (OUT), and use a Phillips screwdriver to turn the wire hatch screw clockwise. NOTE z Strip some insulation off the bare wire end according to the depth of the installation hole. z The maximum screw torque of wire hatch is 0.4 N•m.
Mounting Mounting 1. Disassemble Panel Switch 1 and Panel Switch 3 from Renogy ONE. 2. Put Renogy ONE on the base, and use the Phillips screwdriver to tighten the 4 M2 screws through the mounting holes, so that the Renogy ONE is fixed on the base. NOTE z Make sure that Renogy ONE is installed securely to prevent it from falling off. 3.
Activation Activation Renogy ONE is easy to use. For initial use, Renogy ONE guides you through Wi-Fi connection, DC Home binding, and device adding via the activation wizard. CAUTION z You can tap Skip in the upper right corner of the main interface on Renogy ONE to skip some of the wizard steps. You can re-complete the activation operations through Settings. z To monitor and operate connected devices remotely, you need to bind Renogy ONE to the DC Home app under stable Internet access.
Operation Wi-Fi Binding Add Devices/Smart Accesories Operation Wi-Fi On the home page of Renogy ONE, go to Settings > System > Network > WLAN. NOTE z Renogy ONE supports 2.4 GHz Wi-Fi only. Binding If you did not follow the system wizard to bind Renogy ONE to the DC Home app, please follow the steps below. Method 1: Go to Settings > System > Bind, and then scan the QR code to bind Renogy ONE to the DC Home app.
Operation Wi-Fi Binding Add Devices/Smart Accesories NOTE z To ensure good compatibility, it is recommended to use Renogy energy devices and smart accessories. INFO z For adding smart accessories to Renogy ONE via Zigbee, resetting accessories is required. For details, refer to the instructions in the user manuals of specific smart accessories.
Power On/Off Power On/Off Press and hold the Power Button on Renogy ONE for 3 seconds to power on/off Renogy ONE.
Control External Loads Control External Loads IN1 CAN/RS485 OUT1 IN2 OUT2 CH2 +- TYPE-C IN3 OUT3 CH3 1. The 3 panel switches of Renogy ONE correspond to 3 panel relays respectively. CH1 Control CH3 Control CH2 Control CH1 2. Press the panel switches to power on/off external loads. ON OFF You can modify the above default settings or set more functions for the panel switch through the DC Home app.
Troubleshooting Troubleshooting Trouble Solution 1. Abnormal power supply. Please check whether the voltage of the power supply is within the normal range (8V to 16V DC). Cannot power on normally 2. Check whether the positive and negative polarities of the power terminals are normal. 3. Renogy ONE is damaged. Please contact our customer service through renogy.com/contact-us/. 1. The device is too far from Renogy ONE. Please move the device near Renogy ONE.
Frequently Asked Questions Frequently Asked Questions 1. Does Renogy ONE have the function of coulometer? No. 2. How to establish connection with different types of batteries? Any Renogy batteries with communication interface (Bluetooth/CAN/RS485) can be connected. Batteries from the third-party can be connected via the Renogy Smart Battery Monitor with Shunt (in planning). 3.
Frequently Asked Questions 9. Does Renogy ONE support WPA3 encrypted Wi-Fi network? No. 10. Does Renogy ONE support 5G Hz Wi-Fi network? No. 11. Why does Renogy ONE need regular system updates? Renogy has always been committed to providing customers with the best user experience. And continuous product improvements are made to enable customers to live a smarter offgrid life.
Maintenance Inspection Cleaning Storage Maintenance Inspection For optimum performance, it is recommended to perform these tasks regularly. z Check the appearance of the Renogy ONE to make sure it is clean and dry. z Ensure the Renogy ONE is installed in a clean, dry and ventilated area. z Ensure there is no damage or wear on the cables. z Ensure the firmness of the connectors and check if there are any loose, damaged or burnt connections.
Emergency Responses Fire Flooding Smell Noise Emergency Responses In the event of any threat to health or safety, always begin with the steps below before addressing other suggestions. z Immediately contact the fire department or other relevant emergency response team. z Notify all people who might be affected and ensure that they can evacuate the area. WARNING z ONLY perform the suggested actions below if it is safe to do so. Fire 1. Disconnect all cables connected to the Renogy ONE. 2.
Technical Support Technical Support For additional support, contact the Renogy technical support team through renogy.com/contactus. Have the following information available when contacting Renogy. z Owner name z Contact information z Order number z Purchase channel z Serial number z Brief description of the issue Visit renogy.com to find relevant documentation or get more support via “Contact Us”. US www.renogy.com CN www.renogy.cn UK uk.renogy.com CA ca.renogy.com AU au.renogy.com JP renogy.
Technical Specifications Technical Specifications Item Parameter Product Name Renogy ONE M1 Model RMS-LP4-G2-US Power Supply 8V to 16V DC (5V DC for USB Type-C) Power Consumption < 2.5W (standby) USB Type-C (5V DC) Ports RJ45 (CAN & RS485) 2-pin 3.81 mm pluggable terminal block (12V DC) Wi-Fi (IEEE 802.11b/g/n 2.4GHz) Wireless Communication Bluetooth 2.1/4.2 and Bluetooth LE Zigbee (IEEE 802.15.
Dimensions Dimensions 181.8mm [7.16in] 86.8mm [3.42in] 140mm [5.51in] 17mm [0.67in] 77mm [3.03in] IN1 68mm [2.68in] +- OUT1 IN2 OUT2 CAN/RS485 IN3 OUT3 TYPE-C 32mm [1.26in] 28mm [1.1in] 107mm [4.21in] 42.2mm [1.66in] CAUTION z Dimensional tolerance of ±0.
FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Privacy Policy Last modified: April 14, 2022 RENOGY (“us”, “we”, or “our”) operates on RENOGY ONE device (hereinafter referred to as the “Service”). This page informs you of our policies regarding the collection, use and disclosure of personal data when you use our Service and the choices you have associated with that data. We use your data to provide and improve the Service. By using the Service, you agree to the collection and use of information in accordance with this policy.
Types of Data Collected █ Personal Data While using our Service, we may ask you to provide us with certain personally identifiable information that can be used to contact or identify you (“Personal Data”).
Personal Data we collect and the specific context in which we collect it. RENOGY may process your Personal Data because: z We need to perform a contract with you z You have given us permission to do so z The processing is in our legitimate interests and it is not overridden by your rights z To comply with the law █ Retention of Data RENOGY will retain your Personal Data only for as long as is necessary for the purposes set out in this Privacy Policy.
The security of your data is important to us but remember that no method of transmission over the Internet or method of electronic storage is 100% secure. While we strive to use commercially acceptable means to protect your Personal Data, we cannot guarantee its absolute security. █ Your Data Protection Rights under the General Data Protection Regulation (GDPR) If you are a resident of the European Economic Area (EEA), the UK or Switzerland, you have certain data protection rights.
issues. Upon your verified request, we will delete your personal information unless an exception applies, and will direct our service providers to do the same. z Get a timely response. You have the right to make two free requests in any 12 month period. We will respond to your request within 45 days, and in more difficult cases we may extend our response time by another 45 days. z Non-discrimination.
RENOGY.COM Visit renogy.com to find relevant documentation or get more support via "Contact Us". Renogy reserves the right to change the contents of this manual without notice. Join the Renogy Power Plus Community by downloading the DC Home App. Find your e-warranty here, and more.