BATTERY BLUETOOTH LITHIUM IRON PHOSPHATE 12V 200Ah Model:RBT200LFP12-BT Version 1.
Important Safety Instructions Please save these instructions. This manual contains important installation, operation, and maintenance instructions for the Lithium Iron Phosphate Battery w/ Bluetooth. Please observe these instructions and keep them located near the battery for further reference. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information. Indicates a potentially dangerous condition.
● ● ● ● ● ● ● ● 02 DO NOT place tools on top of the battery. Please keep the battery out of the reach of young children. Please wear proper protective equipment when working on the battery. Please use insulated tools when working on the battery. DO NOT wear jewelry or other metal objects when working on or around the battery. Please ensure adequate and secure mounting of the battery. Please use suitable handling equipment for safe transportation of the battery.
Tabel of Contents General Information ����������������������������������������������������������������������������������������������04 Key Features ����������������������������������������������������������������������������������������������04 Product Overview �������������������������������������������������������������������������������������������������05 Identification of Parts ������������������������������������������������������������������������������������05 Dimensions ����������������������������
General Information The Renogy Lithium Iron Phosphate Battery w/ Bluetooth is designed for the drop-in replacement of deep-cycle lead-acid batteries with its standard BCI group size. Weighing only half of the lead-acid counterparts, the battery can be safely discharged to 100% DOD (Depth of Discharge), delivering twice the energy. Manufactured with automotive grade battery cells, the battery features the highest safety standards and an extended cycle life.
Product Overview Identification of Parts ① Positive Terminal ② Negative Terminal ① ② Dimensions [8.82in] 224mm [8.62in] 219mm [19.13in] 486mm [20.55in] 522mm [8.07in] 205mm [9.
Additional Components ● Long Terminal Bolts (2) The Long Terminal Bolts (M8x1.25x20mm) are used to secure multiple cable lugs on a single battery terminal Preparation Before the installation and operation of the battery, it is recommended to have the following equipment or tools available: ● ● ● ● ● Proper Protective Equipment Insulated Tool(s) Multimeter Battery Cable Battery Charger/Charge Controller Battery Installation Safe and reliable installation requires trained and certified technicians.
rosion, and dry. If any problems are detected with the battery, please contact us for assistance. Refer to the last page of the manual for contact information. Sizing Cables Battery cables (sold separately) should be appropriately sized to handle the expected load. Please refer to the following table for the ampacities of copper cables with different gauge sizes. Copper Cable Gauge Size (AWG/mm2) Ampacity (A) 14 (2.08) 20 12 (3.31) 25 10 (5.25) 35 8 (8.36) 50 6 (13.3) 65 4 (21.1) 85 2 (33.
To connect multiple batteries in parallel, first connect the Positive Terminals of the batteries to each other. Then, connect the Negative Terminals of the batteries to each other. Finally, connect the Positive Terminal of the first battery and the Negative Terminal of the last battery to the system. This type of arrangement is used to increase the overall battery capacity while keeping the battery voltage the same.
Installation Environment The battery should be installed in a clean, cool, and dry place, keeping water, oil, and dirt away from the battery. The accumulation of these materials on the battery can cause current leakage, resulting in self-discharge and a possible short-circuit. Sufficient air flow must be provided to prevent excessive heat build-up and to minimize temperature variation between the paralleled connected batteries. Battery Operation ● ● DO NOT overcharge or overdischarge the battery.
until the battery voltage reaches 14.4V. Then, the battery is charged at a constant voltage of 14.4V while tapering the charge current. The standard charging process is considered complete when the charge current is less than 10A. However, leaving the battery on float will continue to balance the battery cells and will not damage the battery. The standard charging process normally takes 5.5 hours. Safe charging requires battery temperatures between 32°F and 131°F (0°C and 55°C).
● ● ● Clean the top of the battery and terminals with a damp cloth or non-metallic brush. A household cleaner may be used if the battery is extremely dirty. Dry the battery with a clean cloth and keep the area around the battery clean and dry. Ensure the battery is completely dry before reconnecting it to the charging source and/or loads. Checking Voltage Please check the battery voltage periodically to assess battery health.
Battery Management System Warning and Protection The battery contains a battery management system (BMS) that warns the user and protects the battery from overvoltage, undervoltage, overcurrent, short circuit, high temperature, and low temperature. Please refer to the following table for the triggering and recovery condition of each warning and protection.
Battery Operation Status Charge Low Temperature Protection Warning Discharge Low Temperature Protection Warning Charge Overcurrent Primary Protection Secondary Protection Warning Discharge Overcurrent Primary Protection Secondary Protection Short Circuit ● ● Protection Condition Trigger Battery Temperature≤32°F (0°C) Recover Battery Temperature≥41°F (5°C) Trigger Battery Temperature≤14°F (-10°C) Recover Battery Temperature≥23°F (-5°C) Trigger Battery Temperature≤-4°F (-20°C) Recover Bat
battery cell group will be closed to shunt the charge current around the highest-voltage battery cell group through the bypass resistor until the voltage difference drops below the set value. To avoid excessive energy loss, the battery cell balancing is only performed during the charging process.
Specifications General Battery Cell Type Lithium Iron Phosphate Rated Capacity (0.3C, 25°C) 200Ah Nominal Voltage 12.8V Voltage Range 10V~14.8V Cycle Life (0.5C, 25°C) 2000 Cycles (100% DOD) Dimension 20.55 x 9.45 x 8.62 inch 522 x 240 x 219 mm Weight 60.2 lbs. / 27.3 kg Connection Method Parallel Terminal Bolt Size M8 x 1.25 x 15 mm Recommended Terminal Torque 88.5 inch·lbs ~106.
FCC Statement 1.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.