Datasheet

5 Drop Test
Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of
100cm. Allowable variation of SPL after test: 10dB.
6 Vibration Test
After being applied vibration of amplitude of 1.5mm with 10 to 55 Hz band of
vibration frequency to each of 3 perpendicular directions for 2 hours.
Allowable variation of SPL after test: 10dB.
7
Solder ability Test
Lead terminals are immersed in rosin for 5 seconds and then immersed in solder
bath of +2705ºC for 51 seconds.90% min. lead terminals shall be wet with solder.
Hand Soldering 360±5 for 1.5 Sec. Recommend using constant searing-iron
8
Terminal / Wire
Strength Pulling Test
The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10
seconds. No visible damage and cutting off.
7. Reliability Test
Continuous life test:
250 Hours continuous operating at +70 ºC with maximum rated voltage applied . Intermittent life test:
Aduty cycle of 1 minute on, 5 minutes off,a minimum of 10000 times at temperature +25 ºC2
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com