Datasheet

No.
Test item
Performance
Test method (refer to IEC60384-14 )
13
Endurance
There should be no visible damage,
legible marking.
Capacitance change ΔC/C≤10%
Increase of Tanδ:
C
R
1uf:
0.008 (10khz)
C
R
>1uf:0.005 (1khz)
Dielectric strength: there shall be no
permanent breakdown or flashover
IR>50% *Rate value
Ref 4.14 clause
Applied voltage 334vac (1.25*U
R
)at
105,1000h. (The voltage should be
subjected to 1000rms for 0.1s every one
hour during test.)
14
Charge and Discharge
Capacitance change ΔC/C≤10%
Increase of Tanδ::
C
R
1uf:0.008 (10khz)
C
R
>1uf:0.005 (1khz)
Dielectric strength: there shall be no
permanent breakdown or flashover
IR>50% *Rate value
Ref 4.15 clause
dv/dt:最大 100v/us
Times: 10,000
Duration of charge:0.5sec
Duration of discharge:0.5sec
Charging voltage:550vdc
Charge resistor:220/C
R
)or
The limited current should be
Metallized Polypropylene Film
Interference Suppression Capacitors
2. Technical Specification
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com