Two Way Wireless PIR Outdoor Detector WL X312 Installation Instructions
Installation Instructions
Table of Contents Installation ..............................................................................................................................4 Introduction ............................................................................................................................4 Mounting .................................................................................................................................4 Mounting Considerations...................................................
Installation Introduction RISCO Group's WL X312 is a unique detector with signal processing based on two Passive Infrared (PIR) channels. The WL X312 has an adjustable detection range. The detector is compatible with all RISCO Group Wireless and Hybrid systems. The following instructions describe the installation of the WL X312. Mounting Mounting Considerations 1. Installation Height: 0.8m - 1.2m (2'8" – 3'11") Typical Installation Height: 1m (3'3") 2.
Installing the WL X312 detector in challenging situations In the following situations, rapid and significant infrared radiation changes can happen in both PIR channels together, resulting in false alarms and therefore care should be taken. 1. Situations in which metal and/or glass objects measuring over 70cm (2’4”) in height from the ground are in the field of view of the detector (cars, metal gates, shutters, metal walls, windows, etc.) 2.
Wall Mount Installation Figure 1 NOTE: Figure 2 I1 The installation knockouts numbering are marked on the back plate. 1. Open the WL 312 front cover (unlock C1, Figure 1). 2. Release internal base (unlock I1, Figure 2). 3. Select mounting installation as follows: Flat Mounting: Open knockouts on external base (Figure 3). • B1 - B4: Wall mounting knockouts • T1: Back tamper knockout 45° angle Mounting (Left side mounting): a. Open knockouts on external base (Figure 3).
Figure 5 Changing Back Tamper position: Left Side Tamper The back tamper is by default secured on the right side of the internal base (Rear view). If you wish to move it to the left side (rear view), do the following (Figure 5): 1. Remove tamper screw 1 in order to release the tamper from position 7. 2. Ensure tamper spring (2) rests over tamper wire base 4. 3. Ensure plastic tamper bracket (3) rests over both 2 and 4. 4. Secure tamper screw (1) into (3) over position 6.
Detection Range Adjustment Slide the moving PIR to the desired position, see figure 6. The range of the lower detection area determines the detection range. The upper PIR is fixed and its detection area is parallel to the ground at all times. The lower detection area changes from 2m to 12m depending on the location of the moving PIR.
Walk test Two minutes after applying power, walk test the protected area to verify proper operation. Adjust the moving PIR for required detection range and reliability. NOTE: When there is traffic in the detection area the detection area may increase due to environmental thermal conditions, therefore it is recommended to increase the detection area from 1.5m to 2m away from the traffic.
CAUTION NOTICE Changes or modifications not expressly approved by RISCO Group may void the user’s authority to operate this equipment. Simultaneous transmissions from two different units may cause message interference resulting in loss of information. The communication quality of this unit may be affected by its surrounding environment. Nearby electrical equipment may interfere with its normal operation.
Figure 9 NOTE: Do not open or close the Swivel Assy Screw since it is used for connecting the swivel parts only (factory tightened). 4. Secure external base to swivel with two screws fastened trough knockouts S1 and S2 (Figure 9). 5. Insert the supplied angle locking screw from the external base through the angle locking screw knockout S3 on the external base to the standard swivel (Figure 9). Rotate the Standard Swivel to the desired position.
NOTE: When marks on the two movable parts are aligned (Figure 9), the Standard Swivel is in 0° vertical/horizontal position. Each click from this position represents shifting of 5° in vertical/horizontal position. 10. Close the front cover (Lock C1, Figure 1) and walk test the detector. NOTE: The screw has to pass through the External Base and locked to the swivel. Replacing Lenses 1. 2. 3. 4. 5. Unlock the six screws that hold the lens holding sleeve from the back of the front cover.
Technical Specification Electrical Current consumption (standby) Current consumption (Alarm transmission) Dead time (Normal Mode) Modulation type Battery life Supervision transmission Address codes Range Battery Frequency 15uA at 3 VDC (average) 43mA at 3 VDC (Max. with LED OFF) 53mA at 3 VDC (Max. with LED ON) 2.5 minutes ASK 3 years (Normal Mode) 0-255 minutes 16 Million 300m (1000 feet) Line of Sight 1 x CR123A 3VDC Lithium Battery 433.92 / 868.65MHz Physical Size (LxWxD) 230 x 121 x 123mm (9 x 4.
FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
RISCO Group Limited Warranty RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product.
Contacting RISCO Group RISCO Group is committed to customer service and product support. You can contact us through our website (www.riscogroup.com) or at the following telephone and fax numbers: United Kingdom USA Tel: +44-161-655-5500 Tel: +1-631-719-4400 technical@riscogroup.co.uk support-usa@riscogroup.com Italy Brazil Tel: +39-02-66590054 Tel: +55-11-3661-8767 support@riscogroup.it support-br@riscogroup.com Spain China Tel: +34-91-490-2133 Tel: +86-21-52-39-0066 support-es@riscogroup.