User's Manual

1
Model:
RW132KL1P; RW132KL2P
EN
Installation Instructions
EN
1 General Description
The Wireless 2-Way Slim Keypad empowered with a proximity
reader comes in two models:
RW132KL1PUSA — a black protection-insulated outdoor model
RW132KL2PUSA — a white indoor model
The keypad operates in either of two modes:
• Full function Mode: Wireless LED operating keypad
• Bypass unit Mode: Used to activate an entry countdown period
Being bi-directional the 2-Way keypad receives a reply status indication
from the panel for each command that it has sent to the panel.
To use functions of the keypad you can use a proximity tag or a code.
2 Activating the Batteries
Remove the batteries red strip to activate the batteries.
3 Quick Device Allocation at the Control Panel
The Keypad is automatically programmed to your control panel
during the on-line installation wizard setup. If you later purchase an
extra keypad you can enroll it as follows:
To quickly allocate a keypad at the control panel:
If the control panel is not already in Learn mode, press the
button on the control panel for 5 seconds; the unit beeps once
as it enters Learn mode (all the LEDs also light up, one after the
other).
Make sure batteries are installed in each keypad before allocating
them.
Send a signal transmission from the keypad by pressing and
simultaneously for at least 2 seconds; the control panel beeps
once to accept or beeps three times to reject. Once accepted, the
system announces the device type and its zone (for example,
“Keypad, zone 1”).
When the keypads have been enrolled, short-press the control panel
button
to exit Learn mode; the unit beeps once and the LEDs
stop flashing.
Note: For future use, it is recommended to write down the keypad
description, zone number, and installation location of each allocated
keypad.
4 Buzzer and LED Indications
Buzzer Indications:
Duration
Operation
Long beep
Confirmation
3 short beeps Wrong code
Pulsed beeps Exit/enty beeps (programmable)
Short beep Each key press
LED Indciations:
Color
State
Status
Blue Blink During communcation with the
panel
Red On
Slow flash
Rapid flash
System fully or partially armed
During Exit dealy
During alarm
Green
Blink
Trouble indication in the
system while the system is
unset
Green/Red toggle Toggle
Waiting for code to be
entered
5 Using the Proxmity Tag
The proximity tag, is correctly
used by applying it within a
2 cm distance from the
key
as shown in the
illustration (after waking the
keypad by pressing the
appropriate key).
6 Common Operations
Operation Quick High security mode
1
Set (Away Arm)
Press Press
2
Part Set (Stay Arm)
3
Press Press
2
Unset (Disarm)
1. Press > Code or 2. Proximity tag
(after wakeup)
Notes:
1.
Consult your installer for the operations defined with
a code.
2.
The proximity tag can
be
used instead
of code.
3.
For Part Setting (Stay Arming) with
no
entry delay press the key for
two
seconds.
7 Technical Specifications
Battery type
CR123, 3V lithium battery (x 2)
Current consumption
10µA stand by; 100 mA Max.
Battery life
3 years (for typical use)
Frequency
13.56MHz
Operating/storage temperature
-40° – 70°C (-40° – 159°F)
Dimensions
100 mm X 45 mm X 25 mm (3.9 x
1.8 x .98 inches)
Weight (incl batteries)
0.157 kg
Blue
Red
Green
2W WL White Slim Int. KP+Prox9152W WL White Slim Int. KP+Prox915