Dual Technology Outdoor Detector Relay Mode Installation Instructions
WatchOUT DT Relay Mode Installation
WatchOUT Dual Technology Outdoor Detector: Relay Mode Installation Rokonet’s Dual Technology Outdoor detector, WatchOUT, is a unique detector with signal processing based on two Passive Infrared (PIR) channels and two Microwave (MW) channels. The detector can operate as a regular relay detector connected to any control panel, or as a BUS accessory when connected to Rokonet’s ProSYS control panel via the RS485 BUS, thus having unique remote control and diagnostic capabilities.
Figure 5: Changing Back Tamper position: Left Side Tamper The back tamper is by default secured on the right side of the internal base (Rear view). If you wish to move it to the left side (rear view), do the following (Figure 5): 1. Remove tamper screw 1 in order to release the tamper from position 7. 2. Ensure tamper spring 2 rests over tamper wire base 4. 3. Ensure plastic tamper bracket 3 rests over both 2 and 4. 4. Secure tamper screw 1 into 3 over position 6.
Standard Swivel Installation The Outdoor detector packaging contains a standard swivel for flexible installation. Please follow the instructions below for mounting the detector with the Standard Swivel 1. Open Watc hOUT front cover. (Unlock C1, figure 1). 2. Release internal base (Unlock I1, figure 2). 3. Open knockouts on external base (figure 6) Ø W1: Wires knockout Ø S1,S2: Knockouts for securing external base to Standard Swivel Ø S3: External base locking screw knockout 4.
Replacing a Lens 1. Unlock the six screws that hold the lens holding sleeve from the back of the front cover. 2. To release the protective sleeve, gently push the lens from the external side of the front cover. 3. Disconnect the lens from the sleeve by gently pushing the lens clips that secure it to the sleeve. 4. Replace the lens. Place the 4 clips of the lens into the matching holes on the sleeve. 5. Insert the protective sleeve back into place on the front cover.
FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
USA UK ITALY SPAIN Tel. +1 305 592 3820 Fax. +1 305 592 3825 Email: sales@rokonetusa.com Tel. +44 (0)161 655 5500 Fax. +44 (0) 161 655 5501 Email: sales@riscogroup.co.uk Tel. +39 02 392 5354 Fax. +39 02 392 5131 Email: info@rokonet.it Tel. +34 91 4902133 Fax. +34 91 4902134 Email: sales@rokonet.es BRAZIL Tel. +55 11 3661 8767 Fax. +55 11 3661 7783 Email: rokonet@rokonet.com.br ISRAEL Tel. +972 (0)3 9637777 Fax. +972 (0)3 9616584 Email: info@rokonet.co.il 5IN315DT B www.rokonet.