200 series SmartPanels 1.
This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
1200 Series SmartPanels 1.0 User Manual Content Preface 1.1 1.2 1.3 2 RSP-1232HL SmartPanel 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3 3.3 3.4 14 Licensing ........................................................................................................................ 14 Intercom App ................................................................................................................ 14 3.2.1 Operation ..........................................................................................
1200 Series SmartPanels 1.0 User Manual 1 Preface Thank you for choosing a Riedel product. This PDF document provides detailed information about the Riedel SmartPanels, pin outs, mechanical and electrical data. This manual is available in additional formats: CHM "Compiled HTML Help" is the standard format for Windows online help and .
1200 Series SmartPanels 1.0 User Manual 1.1 Information Symbols The following tables are used to indicate hazards and provide cautionary information in relation to the handling and use of the equipment. Environment · Never place the devices in an area of high dust particles or humidity. · Never place containers with any liquids on top of the devices. · If the devices have been exposed to a cold environment and transferred to a warm environment, condensation may form inside the housing.
1200 Series SmartPanels 1.0 User Manual 1.2 Web-Interface Firmware Version This Manual refers to the RSP-1232HL firmware version: 1.0.x The “x” in the firmware version indicates the bugfix version that is described in the related release notes. The firmware version can be checked in the SmartPanel and in the web interface: Enter the IP address of the AES67 interface (Ethernet connectors) of the SmartPanel in the web browser of a PC on the same network.
1200 Series SmartPanels 1.0 User Manual 1.3 About 1200 Series SmartPanels Building upon the technology that powers its SmartPanel app-driven user interfaces, Riedel Communications proudly introduced the new 1200 series SmartPanel today. The RSP-1232HL represents a quantum leap forward in workflow flexibility, power, and connectivity.
1200 Series SmartPanels 1.0 User Manual 2 RSP-1232HL SmartPanel The unique feature set of Riedel's RSP-1232HL SmartPanel includes 3 high-resolution, sunlight readable, multi-touch color displays and 32 lever keys including rotary encoders in 2RU. Features 2.
1200 Series SmartPanels 1.0 User Manual 2.
1200 Series SmartPanels 1.0 User Manual 2.3 Lever Key Numbering The lever keys are numbered as follows: 2.4 Power-Up Connect the RSP-1232HL with the mains voltage and wait until the SmartPanel has booted. If the SmartPanel is not connected to a matrix, you will see the following contents in the info display on the right: Info-display Function Network State of the audio network. Address IP address of the AES67 port. Media Port Selection of the Ethernet-port that is connected to the AES67 network.
1200 Series SmartPanels 1.0 User Manual 2.5 2.7 Info-Display Panel-Menu Basic information and settings of the SmartPanel can be displayed and modified in the Panel menu. The Info-display is located on the right side of the SmartPanel. Ø · · · · Switching of Key-Banks (by prolonged touch) Indication of active functions Switching between panel- and headset operation Open the panel menu figure 12: RSP-1232HL (Info-Display) Touch the menu.
00 Series SmartPanels 1.0 User Manual 2.7.1 Transport 2.7.5 The menu Transport allows selecting the protocol that is used to connect the SmartPanel with a matrix. Info-display Function Current Mode: Shows the current used mode. Selected Mode: Selection of the mode to be used: Auto The SmartPanel selects the mode automatically to establish a successful connection to a matrix. AES3 Cat The SmartPanel establishes a connection via RJ45 matrix connector.
1200 Series SmartPanels 1.0 User Manual 2.7.6 Ø Service Push the new/cleaned air filter in the grille. The menu Service allows storing logfiles and rebooting the SmartPanel. Info-display Function Log Files Stores the internal log file onto an USB stick. This data is used by the Riedel service for analysis and troubleshooting. Reboot Panel 2.8 Save to USB Saves the log file "report_*.tgz" to a previously inserted USB stick. The file is saved in the folder "\Riedel\reports".
1200 Series SmartPanels 1.0 User Manual 3 3.2.1 SmartPanel Firmware This chapter describes the operation of the Intercom app of the SmartPanel: The firmware version 1.0 contains following app: 3.1 Operation App License Version Description Intercom app RSP-1232HL-APP-PRO 1.0 Standard App for Intercom functionality. AES3 app RSP-1232HL-LIC-AES3 1.0 Standard Apps to use the AES3 interface. Lever-Key Functions These licenses are already pre-installed on the SmartPanel.
1200 Series SmartPanels 1.0 User Manual Key-Display Functions Touching the display of a key for half a second opens a drawer with various key functions. The dialog will disappear after 3 seconds of inactivity. Volume Level Master Volume The upper, big rotary encoder is used to adjust the master volume of the SmartPanel. The volume level is temporarily visualized by a vertical bar on the right side of the Info-display. If the Headset mode is enabled, the volume of the connected headset is adjusted.
1200 Series SmartPanels 1.0 User Manual Port Volume The individual port volume is adjusted by turning the integrated rotary encoder in the respective lever key. The volume level is temporarily visualized by a horizontal bar on the corresponding Keydisplay. Pushing the rotary encoder will mute the corresponding port. Muting is also possible by turning down the volume completely. This is indicated by a mute icon in the corresponding Key-display.
1200 Series SmartPanels 1.0 User Manual Scroll Lists To call up scroll lists configured in the Director on a 1200 smart panel, the respective configured rotary encoder must be pressed twice (double-click). In the respective key display, either the alphanumeric name search (Search) or the function type (C2 Port/L2 Port, ...) can now be selected by turning and pressing the rotary knob in order to select a scroll list entry. 3.2.
1200 Series SmartPanels 1.0 User Manual Common Signalization In Talk/Listen mode, the signalization depends on the configuration of the group color: · · If the group color is indicated via the key ring, the signalization is indicated via the display. If the group color is indicated via the display, the signalization is indicated via the key ring. Display Description Call (incoming) The Key-display is highlighted (fade in / out) while a call is incoming if the port is not muted.
1200 Series SmartPanels 1.0 User Manual 3.2.3 Lever-Groups 3.2.4 The keys of the SmartPanel can be assigned into up to 16 groups. For an easy identification each group has an separate group color. The group color can be selected in Key Properties in the Director software: right-click on the respective key > Properties > 'General' tab > 'Group color'. The group color is indicated either in the key ring or in the display of the SmartPanel.
1200 Series SmartPanels 1.0 User Manual 3.2.5 Key-Banks Key Banks – a new take on shift pages – are layers of keys that are accessed by simply touching a button on the screen. The Info-Display shows two key banks in the main. The user can switch between the key banks by touching the respective name for 0.5 seconds. The active key bank is highlighted in the Info-Display by a thicker border. Furthermore the color of the active Key-Bank is shown as border in both Key-Displays.
1200 Series SmartPanels 1.0 User Manual 3.3 Web Interface 3.4 Firmware Update The SmartPanel has a web interface that can be used to update the SmartPanel. There are two ways to update the firmware of the RSP-1232HL SmartPanel: Enter the IP address of the AES67 interface (Ethernet connectors) of the SmartPanel in the web browser of a PC on the same network. 1. Via USB pen drive 2. Via web interface The IP addresses of the SmartPanel are displayed in the Panel-Menü > Network > AES67.
1200 Series SmartPanels 1.0 User Manual Ø · The SmartPanel is automatically rebooting after removing the USB pen drive. Click on the 'INSTALL' button. The firmware update is finished now. figure 34: install figure 30: rebooting The selected firmware is transferred into the SmartPanel. A bar graph visualizes the update progress.
1200 Series SmartPanels 1.0 User Manual 4 4.1 Overall Appendix Power 100 - 240 VAC, 50 - 60 Hz power consumption Technical Specifications Dimensions Front Elements supply voltage width 483 mm / 19" (445 mm / 17.5", installing dimensions) Keys 32× software-assignable lever keys height 88 mm / 3.5" Rotaries 2× rotary encoders for data entry depth 95 mm / 3.
1200 Series SmartPanels 1.0 User Manual 4.2 Expansion port Ports / Pinouts In this chapter the Ports/Pinouts of the RSP-1232HL are shown. Ethernet port The Expansion connector is used to connect Expansion Panels. 1 8 The Ethernet connectors are used to connect an intercom network (AES67). This port is 1000Base-T compatible.
1200 Series SmartPanels 1.0 User Manual GPI IN port GPI OUT port The GPI input connector contains 3 single ports. 5 9 1 6 The GPI output connector contains 3 single ports.
1200 Series SmartPanels 1.
1200 Series SmartPanels 1.0 User Manual 4.3 Maintenance Recommendations Following points are strongly recommended to prevent malfunction of the system. 4.4 Service If you have any further questions, we offer comprehensive customer service options for this product including: General · Check the functionality of the fan. Daily None Weekly None Monthly · Check fan dust filters and exchange them if necessary.
1200 Series SmartPanels 1.
1200 Series SmartPanels 1.0 User Manual Voltages GPI IN port Volume (Master) Volume (Port) 25 15 16 Volume (Sidetone) 16 Volume Level (Intercom-App) 15 -WWeb Interface 21 Web Interface (Firmwre Update) 22 Weekly Maintenance Recommendations 27 -XXLR-4 male (Rev.
01-000HB03EG-A10 Riedel Communications GmbH & Co. KG | Uellendahler Str. 353 | 42109 Wuppertal | Germany www.riedel.