01-000HB03EG-B00 User Manual DR 05 A .10 FT .20 20 1200 series SmartPanels 1.
This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
1200 Series SmartPanels 1.1 User Manual Content Preface 2 RSP-1216HL SmartPanel 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3 5 5.3 6.1 6.2 6.3 39 Ports / Pinouts .............................................................................................................. 39 Maintenance Recommendations .............................................................................. 42 Service ........................................................................................................................
1200 Series SmartPanels 1.1 User Manual 1 Preface Thank you for choosing a Riedel product. This PDF document provides detailed information about the Riedel SmartPanels, pin outs, mechanical and electrical data. This manual is available in additional formats: CHM "Compiled HTML Help" is the standard format for Windows online help and .Net applications EPUB "Electronic Publishing format" is a cross-platform e-book standard DR 05 A .10 FT .
1200 Series SmartPanels 1.1 User Manual 1.1 Information Symbols The following tables are used to indicate hazards and provide cautionary information in relation to the handling and use of the equipment. Environment · Never place the devices in an area of high dust particles or humidity. · Never place containers with any liquids on top of the devices. · If the devices have been exposed to a cold environment and transferred to a warm environment, condensation may form inside the housing.
1200 Series SmartPanels 1.1 User Manual Laser Safety 1200 series SmartPanels can be equipped with optical fiber modules (FOM) for the data transmission over a fiber. Observe the following guidelines and warnings: · Because invisible radiation might be emitted from the aperture of SFPs when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures. · Do not look at fibers that connect to unknown sources.
1200 Series SmartPanels 1.1 User Manual 1.3 Web-Interface Firmware Version This Manual refers to the 1200 series SmartPanels with the firmware version: 1.1.x The “x” in the firmware version indicates the bugfix version that is described in the related release notes. The firmware version can be checked in the SmartPanel and in the web interface: Enter the IP address of the AES67 interface (Ethernet connectors) of the SmartPanel in the web browser of a PC on the same network.
1200 Series SmartPanels 1.1 User Manual 1.4 About 1200 Series SmartPanels Building upon the technology that powers its SmartPanel app-driven user interfaces, Riedel Communications proudly introduced the new 1200 series SmartPanel today. The RSP-1232HL represents a quantum leap forward in workflow flexibility, power, and connectivity.
1200 Series SmartPanels 1.1 User Manual 2 RSP-1216HL SmartPanel The unique feature set of Riedel's RSP-1232HL SmartPanel includes 3 high-resolution, sunlight readable, multi-touch color displays and 16 lever keys including rotary encoders in 1RU. Features Operating Elements figure 6: front view (RSP-1216HL) figure 7: rear view (RSP-1216HL) Panel Microphone Connector (6.
1200 Series SmartPanels 1.
1200 Series SmartPanels 1.1 User Manual 2.3 Lever Key Numbering The lever keys are numbered as follows: 2.4 Power-Up Connect the RSP-1216HL with the mains voltage and wait until the SmartPanel has booted. If the SmartPanel is not connected to a matrix, you will see the following contents in the info display on the right: Info-display Function Network State of the audio network. Address IP address of the AES67 port. Media Port Transport Selected DR 05 A .10 FT .
00 Series SmartPanels 1.1 User Manual 2.5 Volume DR 05 A .10 FT .20 20 Master Volume The right red rotary encoder is used to adjust the master volume of the SmartPanel. The volume level is temporarily visualized by a vertical bar on the right side of the Info-display. If the Headset mode is enabled, the volume of the connected headset is adjusted. The volume levels of speaker and headset can be set independently. Pushing the right rotary encoder will mute the speaker.
1200 Series SmartPanels 1.1 User Manual Open the Panel-Menu Info-Display Ø Ø The Info-display is located on the right side of the SmartPanel. · · · · Switching of Key-Banks (by prolonged touch) Indication of active functions Switching between panel- and headset operation Open the Panel-Menu Wipe from right to left on the info display to show the menu. Touch the gear icon to open the Panel-Menu.
1200 Series SmartPanels 1.1 User Manual 2.7 Audio Technical Specifications Maximum Level Audio A/B Output +24 dBu @ 0 dBFS, 2 kΩ load +23 dBu @ 0 dBFS, 600 Ω load Audio A/B Input +24 dBu Headset Phones +20.
1200 Series SmartPanels 1.1 User Manual General Power supply voltage 100 - 240 VAC, 50 - 60 Hz power consumption Dimensions 483 mm / 19" (445 mm / 17.5", installing dimensions) height 44 mm / 1.7" depth 95 mm / 3.7" form factor 19”, 1RU Weight 2.3 kg / 5.1 lbs Cooling fan noise (speed temperature controlled) <23 dB(A) idle, 34 dB(A) max. fan speed Environment operating temperature 0° … +45°C Reset @ 0.7m (low noise emission according GK15 / DIN 15996) DR 05 A .10 FT .20 20 2.
1200 Series SmartPanels 1.1 User Manual 3 RSP-1232HL SmartPanel The unique feature set of Riedel's RSP-1232HL SmartPanel includes 3 high-resolution, sunlight readable, multi-touch color displays and 32 lever keys including rotary encoders in 2RU. Features Operating Elements figure 18: RSP-1232HL (front view) figure 19: RSP-1232HL (rear view) Panel Microphone Connector (6.
1200 Series SmartPanels 1.
1200 Series SmartPanels 1.1 User Manual 3.3 Lever Key Numbering The lever keys are numbered as follows: 3.4 Power-Up Connect the RSP-1232HL with the mains voltage and wait until the SmartPanel has booted. If the SmartPanel is not connected to a matrix, you will see the following contents in the info display on the right: Info-display Function Network State of the audio network. Address IP address of the AES67 port. Media Port Transport Selected Shows the current selected transport mode.
1200 Series SmartPanels 1.1 User Manual 3.5 Volume DR 05 A .10 FT .20 20 Master Volume The upper, big rotary encoder is used to adjust the master volume of the SmartPanel. The volume level is temporarily visualized by a vertical bar on the right side of the Info-display. If the Headset mode is enabled, the volume of the connected headset is adjusted. The volume levels of speaker and headset can be set independently. Pushing the big rotary encoder will mute the speaker.
1200 Series SmartPanels 1.1 User Manual 3.6 Navigation in the Panel-Menu Info-Display · Turning the lower, · Select the next / previous menu item small rotary encoder. · Change values / settings · Wiping the touch screen. The Info-display is located on the right side of the SmartPanel. · · · · Switching of Key-Banks (by prolonged touch) Indication of active functions Switching between panel- and headset operation Open the Panel-Menu · Pushing the lower, small rotary encoder.
1200 Series SmartPanels 1.1 User Manual Replacing the Air Filter Ø The air filters are located on both device sides. Ø Use your fingers to pull out the grille including the air filter on the upper side. Ø 21 Remove the air filter out of the grille. Push the new/cleaned air filter in the grille. Repeat this step on the opposite side of the chassis. DR 05 A .10 FT .20 20 Ø Ø Insert the grille into the bottom of the SmartPanel first and then press it evenly. 01-000HB03EG-B00 3.
1200 Series SmartPanels 1.1 User Manual 3.8 Audio Technical Specifications Maximum Level Audio A/B Output +24 dBu @ 0 dBFS, 2 kΩ load +23 dBu @ 0 dBFS, 600 Ω load Audio A/B Input +24 dBu Headset Phones +20.
1200 Series SmartPanels 1.1 User Manual General Power supply voltage 100 - 240 VAC, 50 - 60 Hz power consumption Dimensions 483 mm / 19" (445 mm / 17.5", installing dimensions) height 88 mm / 3.5" depth 95 mm / 3.7" form factor 19”, 2 RU Weight 3.4 kg / 7.4 lbs Cooling fan noise (speed temperature controlled) <23 dB(A) idle, 26 dB(A) max. fan speed Environment operating temperature 0° … +45°C Reset @ 0.7m (low noise emission according GK15 / DIN 15996) DR 05 A .10 FT .20 20 3.
1200 Series SmartPanels 1.1 User Manual 4 Panel-Menu 4.4 Basic information and settings of the SmartPanel can be displayed and modified in the Panel menu. 4.1 Touch the gear icon on the Info-Display to open the Panel menu.
1200 Series SmartPanels 1.1 User Manual 4.6 Matrix The menu Matrix shows information about the connected Matrix. Content is only available if the SmartPanel is connected with a Matrix. Service The menu Service allows storing logfiles and rebooting the SmartPanel. Info-display Function Function Net Net number of the connected matrix. Stores the internal log file onto an USB stick. This data is used by the Riedel service for analysis and troubleshooting. Node Node number of the connected matrix.
1200 Series SmartPanels 1.1 User Manual 5 5.2.1 SmartPanel Firmware This chapter describes the operation of the Intercom app of the SmartPanel: The firmware version 1.1 contains following app: 5.1 Operation Lever-Key Functions App License Version Description Intercom RSP-1232HL-APP-PRO 1.0 Standard App for Intercom functionality. AES3 RSP-1232HL-LIC-AES3 1.0 App to use the AES3 interface. AES67 4-Wire AES67-4W-APP 1.0 App to use the AES67 4-wire.
1200 Series SmartPanels 1.1 User Manual Key-Display Functions Scroll Lists figure 30: Key-Display functions To call up scroll lists configured in the Director on a 1200 smart panel, the respective configured rotary encoder must be pressed twice (double-click). In the respective key display, either the alphanumeric name search (Search) or the function type (C2 Port/L2 Port, ...) can now be selected by turning and pressing the rotary knob in order to select a scroll list entry. DR 05 A .10 FT .
1200 Series SmartPanels 1.1 User Manual Signalization Talk/Listen-Modus The LED-ring as well as the corresponding Key-display can be used to indicate any activity of the respective port. The indication varies depending on the selected workflow mode (Talk/Mute or Talk/Listen). In Talk/Listen mode, the signalization depends on the configuration of the group color: Furthermore a symbol can be displayed in the corresponding ports.
1200 Series SmartPanels 1.1 User Manual 5.2.3 Common Signalization Signal Display Description The Key-display is highlighted (fade in / out) while a call is incoming if the port is not muted. Beep (incoming) The animated bell icon shows where the Beep being received is coming from. Beep (outgoing) The animated bell shows that the user is beeping a remote panel. Port occupied This symbol indicates that the remote panel is currently in a call.
1200 Series SmartPanels 1.1 User Manual 5.2.4 Operation Mode 5.2.5 The 1200 SmartPanel series offers two different ways of operation: · · Key-Banks Key Banks – a new take on shift pages – are layers of keys that are accessed by simply touching a button on the screen. The Info-Display shows two key banks in the main. The user can switch between the key banks by touching the respective name for 0.5 seconds. The active key bank is highlighted in the Info-Display by a thicker border.
1200 Series SmartPanels 1.1 User Manual 5.3 5.3.1 Web Interface Asset Drawer The asset drawer shows all SmartPanels found in the network. Double-Clicking an entry opens the SmartPanel in the Work Surface. The SmartPanel features a web interface for configuration purpose. Enter the IP address of the AES67 interface (Ethernet connectors) of the SmartPanel in the web browser of a PC in the same network. The IP addresses of the SmartPanel are displayed in the Panel-Menü > Network > AES67. DR 05 A .
1200 Series SmartPanels 1.1 User Manual 5.3.2 Individualization the Asset Drawer The following adjustments can be made to change the size and contents of the asset drawer. Work Surface The work surface the user-defined key assignments of the SmartPanel are displayed and configured. A SmartPanel can be opened in the Work Surface by double-clicking it in the Asset Drawer. Adjusting the width of the Asset Drawer Ø Ø Move the mouse to the right edge of the asset drawer.
1200 Series SmartPanels 1.1 User Manual 5.3.3 5.3.3.1 Main Menu 5.3.4 Parameter Drawer In the parameter drawer, the inputs/outputs of the audio paths A/B can be defined. Firmware Manager Audio A/B The Audio A and Audio B tabs are used to configure the input and output of the audio patch. Firmware Update Buttons Buttons to update the firmware. A maximum of ten SmartPanels can be updated in parallel. SELECT FW Opens a dialog to select the firmware file (.cfw).
1200 Series SmartPanels 1.1 User Manual General Settings Stream Setup Multicast IP The digital AES67 4 wires are configured in the stream setup. Different parameters are available depending on whether an input or output is configured. Field to enter the Multicast address of the RTP sender (224.0.0.0 ... 239.255.255.254) Inputs: The button allows loading the settings from a SDP file. Outputs: The button allows saving the settings to a SDP file.
1200 Series SmartPanels 1.1 User Manual 5.4 Ø Firmware Update The SmartPanel is automatically rebooting after removing the USB pen drive. There are two ways to update the firmware of the 1200 series SmartPanels: The firmware update is finished now. 1. Via USB pen drive 2. Via web interface figure 47: rebooting Firmware update via USB pen drive Format an USB pen drive in the FAT32 or NTFS file format. Create the folders: "\\Riedel\firmware\unattended".
1200 Series SmartPanels 1.1 User Manual · Firmware update via web interface Click on the 'INSTALL' button. Enter the IP address of the AES67 interface (Ethernet connectors) of the SmartPanel in the web browser of a PC on the same network. figure 52: install The IP addresses of the SmartPanel are displayed in the Panel-Menu > Network > AES67. The selected firmware is transferred into the SmartPanel. A bar graph visualizes the update progress.
1200 Series SmartPanels 1.1 User Manual 5.5 AES67 4-wire App · Click on 'Stream Setup'. This chapter describes the required steps to activate the AES67 4-wire operation. The SmartPanel must be licensed for this function. figure 61: stream setup 1) 2) Touch the gear icon in the Info-display. Select the menu: 'Transport'. Select the option 'AES67'. The AES67 4-wire can only be used if the SmartPanel is connected to the matrix via 'AES67'. Enter the stream parameters.
1200 Series SmartPanels 1.1 User Manual · Quickly change between different channels within a stream by selecting it in the drop-down list. (The change must be confirmed by clicking the at the top of the web interface.) button figure 65: change channel When you switch back to the 4-wire analog system, your AES67 configuration is saved for later use. DR 05 A .10 FT .
1200 Series SmartPanels 1.1 User Manual 6 6.1 Appendix Expansion port The Expansion connector is used to connect Expansion Panels. Ports / Pinouts In this chapter the Ports/Pinouts of the 1200 series SmartPanels are shown. 1 8 Ethernet port The Ethernet connectors are used to connect an intercom network (AES67). This port is 1000Base-T compatible.
1200 Series SmartPanels 1.1 User Manual GPI IN port GPI OUT port The GPI input connector contains 3 single ports.
1200 Series SmartPanels 1.
1200 Series SmartPanels 1.1 User Manual 6.2 6.3 Maintenance Recommendations Following points are strongly recommended to prevent malfunction of the system. Service If you have any further questions, we offer comprehensive customer service options for this product including: General · § § § § § § Check the functionality of the fan. Daily None Weekly Your primary point of contact for any service issues is your local dealer.
1200 Series SmartPanels 1.
1200 Series SmartPanels 1.1 User Manual Signalization 28 SmartPanel Firmware SN# -W- 26 Web Interface 24 Status LEDs (RSP-1216HL) 10 Status LEDs (RSP-1232HL) 17 Stream Setup Sub-D-9 male 42 -X- 40 XLR-4 male (Rev.
01-000HB03EG-B00 DR 05 A .10 FT .20 20 Riedel Communications GmbH & Co. KG | Uellendahler Str. 353 | 42109 Wuppertal | Germany www.riedel.